Dynamic corneal biomechanics in different cell layers: in keratoconus and normal eyes

被引:7
|
作者
Alvani, Azam [1 ,2 ]
Hashemi, Hassan [1 ,2 ]
Pakravan, Mohammad [3 ]
Mahbod, Mirgholamreza [2 ]
Amanzadeh, Kazem [4 ]
Seyedian, Mohammad Amin [2 ]
Yaseri, Mehdi [5 ]
Jafarzadehpur, Ebrahim [6 ]
Fotouhi, Akbar [5 ]
机构
[1] Univ Tehran Med Sci, Sch Med, Dept Ophthalmol, Tehran, Iran
[2] Noor Eye Hosp, Noor Ophthalmol Res Ctr, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Ophthalm Epidemiol Res Ctr, Tehran, Iran
[4] Noor Eye Hosp, Noor Res Ctr Ophthalm Epidemiol, Tehran, Iran
[5] Univ Tehran Med Sci, Sch Publ Hlth, Dept Epidemiol & Biostat, Tehran, Iran
[6] Iran Univ Med Sci, Sch Rehabil, Dept Optometry, Tehran, Iran
关键词
confocal microscopy; corneal biomechanics; corneal endothelium; Corvis Scheimpflug Technology; keratoconus; VIVO CONFOCAL MICROSCOPY; PARAMETERS; ELEVATION; ANTERIOR; MICROSTRUCTURE; TOPOGRAPHY;
D O I
10.1111/opo.12768
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose This study aimed to determine the relationship between corneal cellular structures and biomechanical deformation parameters in keratoconic (KC) and healthy eyes. Methods In this prospective comparative study, 29 eyes of 29 KC patients were age- and gender-matched with 28 eyes of 28 healthy individuals using frequency matching. Corneal parameters examined included the density of basal epithelial cells, anterior keratocytes, posterior keratocytes and endothelial cells as assessed by in vivo corneal confocal microscopy (HRT III-RCM, Heidelberg Engineering, ). Additionally, the coefficient of variation of endothelial cell size (CV) and the percentage of hexagonal endothelial cells (HEX%) were measured by specular microscopy (Konan NSP-9900, Konan Medical, ). Further, biomechanical deformation parameters were derived from Corvis Scheimpflug Technology (Corvis ST, Oculus, ). All cellular and biomechanical deformation parameters in KC and normal groups were compared, and the relationship between cellular and biomechanical parameters calculated. Results In the KC group, the highest concavity (HC) delta arc length and maximum delta arc length were associated with endothelial cell density (Beta = -0.39, p = 0.03 and Beta = -0.60, p < 0.001, respectively). Furthermore, there was a significant association between HC deflection length and HEX% (Beta = -0.67, p = 0.001). In the normal group, HC delta arc length and HC deflection length were significantly associated with endothelial cell density (Beta = 0.46, p = 0.02; and Beta = -0.51, p = 0.01, respectively). HC time, HC deformation amplitude and applanation 1 delta arc length were associated with CV (Beta = 0.50, p = 0.01; Beta = 0.27, p = 0.009; and Beta = -0.57, p = 0.002, respectively). Applanation 1 and applanation 2 deformation amplitudes were associated with HEX% (Beta = -0.49, p = 0.005; and Beta = -0.46, p = 0.02). Conclusions Biomechanical deformation parameters were significantly correlated with endothelial cell properties in both KC and normal groups, thereby indicating the importance of the integrity of endothelial cells to the biomechanical properties of both KC and normal corneas.
引用
收藏
页码:414 / 423
页数:10
相关论文
共 50 条
  • [41] Analysis of Corneal Wavefront Aberrations for Differentiation Between Keratoconus, Pellucid Marginal Degeneration and Normal Eyes
    Ott, D. -L.
    Buehren, J.
    Klaproth, O. K.
    Schwarz, R.
    Kohnen, T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [42] Evaluation of corneal topography and tomography in fellow eyes of unilateral keratoconus patients for early detection of subclinical keratoconus
    Thulasidas, Mithun
    Teotia, Prateek
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (11) : 2415 - 2420
  • [43] Corneal Densitometry: Repeatability in Eyes With Keratoconus and Postcollagen Cross-Linking
    Pahuja, Natasha
    Shetty, Rohit
    Subbiah, Priya
    Nagaraja, Harsha
    Nuijts, Rudy M. M. A.
    Jayadev, Chaitra
    CORNEA, 2016, 35 (06) : 833 - 837
  • [44] Differentiation of forme fruste keratoconus from normal cornea using parameters of corneal tomography, aberration, and biomechanics
    Ueki, Ryotaro
    Maeda, Naoyuki
    Fuchihata, Mutsumi
    Koh, Shizuka
    Kitaoka, Takashi
    Nishida, Kohji
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [45] Corneal Biomechanics and Intraocular Pressure Following Scleral Lens Wear in Penetrating Keratoplasty and Keratoconus
    Kumar, Mukesh
    Shetty, Rohit
    Lalgudi, Vaitheeswaran G.
    Roy, Abhijit S.
    Khamar, Pooja
    Vincent, Stephen J.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2022, 48 (05): : 206 - 209
  • [46] Corneal biomechanics in normal Saudi individuals
    Al-Arfaj, Khalid
    Yassin, Sanaa A.
    Al-Dairi, Walaa
    Al-Shamlan, Fatimah
    Al-Jindan, Mohanna
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2016, 30 (03) : 180 - 184
  • [47] Predictive Analysis Between Topographic, Pachymetric and Wavefront Parameters in Keratoconus, Suspects and Normal Eyes: Creating Unified Equations to Evaluate Keratoconus
    Prakash, Gaurav
    Suhail, Muhammad
    Srivastava, Dhruv
    CURRENT EYE RESEARCH, 2016, 41 (03) : 334 - 342
  • [48] Comparison of corneal tomography using a novel swept-source optical coherence tomographer and rotating Scheimpflug system in normal and keratoconus eyes: repeatability and agreement analysis
    Herber, Robert
    Lenk, Janine
    Pillunat, Lutz E.
    Raiskup, Frederik
    EYE AND VISION, 2022, 9 (01)
  • [49] Long-Term Zonal Average Analysis of Corneal Tomography in Keratoconus Eyes
    Lombardo, Giuseppe
    Serrao, Sebastiano
    Lombardo, Marco
    CORNEA, 2023, 42 (02) : 156 - 163
  • [50] Corneal endothelial cell density and morphology in normal Indian eyes
    Rao, SK
    Sen, PR
    Fogla, R
    Gangadharan, S
    Padmanabhan, P
    Badrinath, SS
    CORNEA, 2000, 19 (06) : 820 - 823