Dynamic corneal biomechanics in different cell layers: in keratoconus and normal eyes

被引:7
|
作者
Alvani, Azam [1 ,2 ]
Hashemi, Hassan [1 ,2 ]
Pakravan, Mohammad [3 ]
Mahbod, Mirgholamreza [2 ]
Amanzadeh, Kazem [4 ]
Seyedian, Mohammad Amin [2 ]
Yaseri, Mehdi [5 ]
Jafarzadehpur, Ebrahim [6 ]
Fotouhi, Akbar [5 ]
机构
[1] Univ Tehran Med Sci, Sch Med, Dept Ophthalmol, Tehran, Iran
[2] Noor Eye Hosp, Noor Ophthalmol Res Ctr, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Ophthalm Epidemiol Res Ctr, Tehran, Iran
[4] Noor Eye Hosp, Noor Res Ctr Ophthalm Epidemiol, Tehran, Iran
[5] Univ Tehran Med Sci, Sch Publ Hlth, Dept Epidemiol & Biostat, Tehran, Iran
[6] Iran Univ Med Sci, Sch Rehabil, Dept Optometry, Tehran, Iran
关键词
confocal microscopy; corneal biomechanics; corneal endothelium; Corvis Scheimpflug Technology; keratoconus; VIVO CONFOCAL MICROSCOPY; PARAMETERS; ELEVATION; ANTERIOR; MICROSTRUCTURE; TOPOGRAPHY;
D O I
10.1111/opo.12768
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose This study aimed to determine the relationship between corneal cellular structures and biomechanical deformation parameters in keratoconic (KC) and healthy eyes. Methods In this prospective comparative study, 29 eyes of 29 KC patients were age- and gender-matched with 28 eyes of 28 healthy individuals using frequency matching. Corneal parameters examined included the density of basal epithelial cells, anterior keratocytes, posterior keratocytes and endothelial cells as assessed by in vivo corneal confocal microscopy (HRT III-RCM, Heidelberg Engineering, ). Additionally, the coefficient of variation of endothelial cell size (CV) and the percentage of hexagonal endothelial cells (HEX%) were measured by specular microscopy (Konan NSP-9900, Konan Medical, ). Further, biomechanical deformation parameters were derived from Corvis Scheimpflug Technology (Corvis ST, Oculus, ). All cellular and biomechanical deformation parameters in KC and normal groups were compared, and the relationship between cellular and biomechanical parameters calculated. Results In the KC group, the highest concavity (HC) delta arc length and maximum delta arc length were associated with endothelial cell density (Beta = -0.39, p = 0.03 and Beta = -0.60, p < 0.001, respectively). Furthermore, there was a significant association between HC deflection length and HEX% (Beta = -0.67, p = 0.001). In the normal group, HC delta arc length and HC deflection length were significantly associated with endothelial cell density (Beta = 0.46, p = 0.02; and Beta = -0.51, p = 0.01, respectively). HC time, HC deformation amplitude and applanation 1 delta arc length were associated with CV (Beta = 0.50, p = 0.01; Beta = 0.27, p = 0.009; and Beta = -0.57, p = 0.002, respectively). Applanation 1 and applanation 2 deformation amplitudes were associated with HEX% (Beta = -0.49, p = 0.005; and Beta = -0.46, p = 0.02). Conclusions Biomechanical deformation parameters were significantly correlated with endothelial cell properties in both KC and normal groups, thereby indicating the importance of the integrity of endothelial cells to the biomechanical properties of both KC and normal corneas.
引用
收藏
页码:414 / 423
页数:10
相关论文
共 50 条
  • [21] Corneal biomechanics in early diagnosis of keratoconus using artificial intelligence
    Yan Huo
    Xuan Chen
    Gauhar Ali Khan
    Yan Wang
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2024, 262 : 1337 - 1349
  • [22] Changes in Corneal Biomechanics in Patients With Keratoconus After Penetrating Keratoplasty
    Yenerel, Nursal Melda
    Kucumen, Raciha Beril
    Gorgun, Ebru
    CORNEA, 2010, 29 (11) : 1247 - 1251
  • [23] Corneal Biomechanics, Refraction, and Corneal Aberrometry in Keratoconus: An Integrated Study
    Pinero, David P.
    Alio, Jorge L.
    Barraquer, Rafael I.
    Michael, Ralph
    Jimenez, Ramon
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (04) : 1948 - 1955
  • [24] Comparison of Corneal Morphologic Parameters and High Order Aberrations in Keratoconus and Normal Eyes
    Sebastian Velazquez, Jose
    Cavas, Francisco
    Miguel Bolarin, Jose
    Alio, Jorge
    BIOINFORMATICS AND BIOMEDICAL ENGINEERING (IWBBIO 2020), 2020, 12108 : 87 - 97
  • [25] Comparison of corneal topographic measurements and high order aberrations in keratoconus and normal eyes
    Colak, Hatice Nur
    Kantarci, Feride Aylin
    Yildirim, Aydin
    Tatar, Mehmet Gurkan
    Goker, Hasan
    Uslu, Hasim
    Gurler, Bulent
    CONTACT LENS & ANTERIOR EYE, 2016, 39 (05) : 380 - 384
  • [26] Distribution Pattern of Total Corneal Thickness in Keratoconus versus Normal Eyes Using an Optical Coherence Tomography
    Hashemi, Hassan
    Heidari, Zahra
    Mohammadpour, Mehrdad
    Momeni-Moghaddam, Hamed
    Khabazkhoob, Mehdi
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2022, 34 (02): : 216 - 222
  • [27] Evaluation of Scheimpflug imaging parameters in subclinical keratoconus, keratoconus, and normal eyes
    Ucakhan, Omur O.
    Cetinkor, Volkan
    Ozkan, Muhip
    Kanpolat, Ayfer
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06) : 1116 - 1124
  • [28] Anterior segment characteristics in normal and keratoconus eyes evaluated with a combined Scheimpflug/Placido corneal imaging device
    Safarzadeh, Masoud
    Nasiri, Nader
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2016, 28 (03): : 106 - 111
  • [29] Ocular, corneal, and internal aberrations in eyes with keratoconus, forme fruste keratoconus, and healthy eyes
    Mohammad Naderan
    Ali Jahanrad
    Mahgol Farjadnia
    International Ophthalmology, 2018, 38 : 1565 - 1573
  • [30] Early diagnosis of keratoconus using corneal biomechanics and OCT derived technologies
    Xiaorui Wang
    Sayo Maeno
    Yixin Wang
    Shizuka Koh
    Shihao Chen
    Andrew J. Quantock
    Siân R. Morgan
    Sally Hayes
    Colm McAlinden
    Eye and Vision, 12 (1)