Dynamic corneal biomechanics in different cell layers: in keratoconus and normal eyes

被引:7
|
作者
Alvani, Azam [1 ,2 ]
Hashemi, Hassan [1 ,2 ]
Pakravan, Mohammad [3 ]
Mahbod, Mirgholamreza [2 ]
Amanzadeh, Kazem [4 ]
Seyedian, Mohammad Amin [2 ]
Yaseri, Mehdi [5 ]
Jafarzadehpur, Ebrahim [6 ]
Fotouhi, Akbar [5 ]
机构
[1] Univ Tehran Med Sci, Sch Med, Dept Ophthalmol, Tehran, Iran
[2] Noor Eye Hosp, Noor Ophthalmol Res Ctr, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Ophthalm Epidemiol Res Ctr, Tehran, Iran
[4] Noor Eye Hosp, Noor Res Ctr Ophthalm Epidemiol, Tehran, Iran
[5] Univ Tehran Med Sci, Sch Publ Hlth, Dept Epidemiol & Biostat, Tehran, Iran
[6] Iran Univ Med Sci, Sch Rehabil, Dept Optometry, Tehran, Iran
关键词
confocal microscopy; corneal biomechanics; corneal endothelium; Corvis Scheimpflug Technology; keratoconus; VIVO CONFOCAL MICROSCOPY; PARAMETERS; ELEVATION; ANTERIOR; MICROSTRUCTURE; TOPOGRAPHY;
D O I
10.1111/opo.12768
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose This study aimed to determine the relationship between corneal cellular structures and biomechanical deformation parameters in keratoconic (KC) and healthy eyes. Methods In this prospective comparative study, 29 eyes of 29 KC patients were age- and gender-matched with 28 eyes of 28 healthy individuals using frequency matching. Corneal parameters examined included the density of basal epithelial cells, anterior keratocytes, posterior keratocytes and endothelial cells as assessed by in vivo corneal confocal microscopy (HRT III-RCM, Heidelberg Engineering, ). Additionally, the coefficient of variation of endothelial cell size (CV) and the percentage of hexagonal endothelial cells (HEX%) were measured by specular microscopy (Konan NSP-9900, Konan Medical, ). Further, biomechanical deformation parameters were derived from Corvis Scheimpflug Technology (Corvis ST, Oculus, ). All cellular and biomechanical deformation parameters in KC and normal groups were compared, and the relationship between cellular and biomechanical parameters calculated. Results In the KC group, the highest concavity (HC) delta arc length and maximum delta arc length were associated with endothelial cell density (Beta = -0.39, p = 0.03 and Beta = -0.60, p < 0.001, respectively). Furthermore, there was a significant association between HC deflection length and HEX% (Beta = -0.67, p = 0.001). In the normal group, HC delta arc length and HC deflection length were significantly associated with endothelial cell density (Beta = 0.46, p = 0.02; and Beta = -0.51, p = 0.01, respectively). HC time, HC deformation amplitude and applanation 1 delta arc length were associated with CV (Beta = 0.50, p = 0.01; Beta = 0.27, p = 0.009; and Beta = -0.57, p = 0.002, respectively). Applanation 1 and applanation 2 deformation amplitudes were associated with HEX% (Beta = -0.49, p = 0.005; and Beta = -0.46, p = 0.02). Conclusions Biomechanical deformation parameters were significantly correlated with endothelial cell properties in both KC and normal groups, thereby indicating the importance of the integrity of endothelial cells to the biomechanical properties of both KC and normal corneas.
引用
收藏
页码:414 / 423
页数:10
相关论文
共 50 条
  • [1] Corneal biomechanics in normal and subclinical keratoconus eyes
    Peyman, Alireza
    Sepahvand, Fatemeh
    Pourazizi, Mohsen
    Noorshargh, Pegah
    Forouhari, Ali
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [2] Corneal biomechanics in normal and subclinical keratoconus eyes
    Alireza Peyman
    Fatemeh Sepahvand
    Mohsen Pourazizi
    Pegah Noorshargh
    Ali Forouhari
    BMC Ophthalmology, 23
  • [3] Comparison of bilateral differential characteristics of corneal biomechanics between keratoconus and normal eyes
    Xian, Yiyong
    Zhao, Yu
    Sun, Ling
    Zhang, Xiaoyu
    Ding, Lan
    Liu, Zesheng
    Li, Yuan
    Ding, Yanlan
    Jiang, Lin
    Zhou, Xingtao
    Shen, Yang
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [4] Changes of Corneal Biomechanics With Keratoconus
    Wolffsohn, James S.
    Safeen, Saima
    Shah, Sunil
    Laiquzzaman, Mohammad
    CORNEA, 2012, 31 (08) : 849 - 854
  • [5] Ocular, corneal, and internal aberrations in eyes with keratoconus, forme fruste keratoconus, and healthy eyes
    Naderan, Mohammad
    Jahanrad, Ali
    Farjadnia, Mahgol
    INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (04) : 1565 - 1573
  • [6] Associations between endothelial cell characteristics and corneal topography findings in different stages of keratoconus
    Reyhan, Ali Hakim
    Karadag, Ayse Sevgi
    Simsek, Ali
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [7] Evaluation of corneal elevation in eyes with subclinical keratoconus and keratoconus using Galilei double Scheimpflug analyzer
    Jafarinasab, Mohammad Reza
    Feizi, Sepehr
    Karimian, Farid
    Hasanpour, Hossein
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (03) : 377 - 384
  • [8] Assessment of Corneal Pachymetry Distribution and Morphologic Changes in Subclinical Keratoconus with Normal Biomechanics
    Song, Peng
    Yang, Kaili
    Li, Pei
    Liu, Yu
    Liang, Dengfeng
    Ren, Shengwei
    Zeng, Qingyan
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [9] Corneal biomechanics in early diagnosis of keratoconus using artificial intelligence
    Huo, Yan
    Chen, Xuan
    Khan, Gauhar Ali
    Wang, Yan
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (04) : 1337 - 1349
  • [10] Optical Quality in Keratoconus Is Associated With Corneal Biomechanics
    Shugyo, Akiko
    Koh, Shizuka
    Inoue, Ryota
    Ambrosio Jr, Renato
    Miki, Atsuya
    Maeda, Naoyuki
    Nishida, Kohji
    CORNEA, 2021, 40 (10) : 1276 - 1281