Mass Transfer Equation for Proteins in Very High-Pressure Liquid Chromatography

被引:53
|
作者
Gritti, Fabrice [1 ]
Guiochon, Georges [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
基金
美国国家科学基金会;
关键词
SOLUTE RETENTION; FINE PARTICLES; SURFACE; DISTRIBUTIONS; DISPERSION; DIFFUSION; VISCOSITY;
D O I
10.1021/ac8026299
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The mass transfer kinetics of human insulin was investigated on a 50 mm x 2.1 mm column packed with 1.7 pm BEH-C-18 particles, eluted with a water/acetonitrile/trifluoroacetic acid (TFA) (68/32/0.1, v/v/v) solution. ne different contributions to the mass transfer kinetics, e.g., those of longitudinal diffusion, eddy dispersion, the film mass transfer resistance, cross-particle diffusivity, adsorption-desorption kinetics, and transcolumn differential sorption, were incorporated into a general mass transfer equation designed to account for the mass transfer kinetics of proteins under high pressure. More specifically, this equation includes the effects of pore size exclusion, pressure, and temperature on the band broadening of a protein. The flow rate was first increased from 0.001 to 0.250 mL/min, the pressure drop increasing from 2 to 298 bar, and the column being placed in stagnant air at 296.5 K, in order to determine the effective diffusivity of insulin through the porous particles, the mass transfer rate constants, and the adsorption equilibrium constant in the low-pressure range. Then, the column inlet pressure was increased by using capillary flow restrictors downstream the column, at the constant flow rate of 0.03 mL/min. The column temperature was kept uniform by immersing the column in a circulating water bath thermostatted at 298.7 and 323.15 K, successively. The results showed that the surface diffusion coefficient of insulin decreases faster than its bulk diffusion coefficient with increasing average column pressure. This is consistent with the adsorption energy of insulin onto the BEH-C18 surface increasing strongly with increasing pressure. In contrast, given the precision of the height equivalent to a theoretical plate (HETP) measurement (+/- 12%), the adsorption kinetics of insulin appears to be rather independent of the pressure. On average, the adsorption rate constant of insulin is doubled from about 40 to 80 s(-1) when the temperature increases from 298.7 to 323.15 K.
引用
收藏
页码:2723 / 2736
页数:14
相关论文
共 50 条
  • [21] Linking high-pressure structure and density of albite liquid near the glass transition
    Gaudio, Sarah J.
    Lesher, Charles E.
    Maekawa, Hideki
    Sen, Sabyasachi
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2015, 157 : 28 - 38
  • [22] Liquid Density Measurement in High-Pressure Region Using Quartz Crystal Resonators
    Yamawaki, Hiroshi
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2024, 45 (06)
  • [23] Association structures of ionic liquid/DMSO mixtures studied by high-pressure infrared spectroscopy
    Jiang, Jyh-Chiang
    Lin, Kuan-Hung
    Li, Sz-Chi
    Shih, Pao-Ming
    Hung, Kai-Chan
    Lin, Sheng Hsien
    Chang, Hai-Chou
    JOURNAL OF CHEMICAL PHYSICS, 2011, 134 (04)
  • [24] High-temperature and high-pressure plastic phase of ice at the boundary of liquid water and ice VII
    Prasad, Dipak
    Mitra, Nilanjan
    PROCEEDINGS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2022, 478 (2260):
  • [25] Measurement Methodology of Low-Shear Viscosity of Reference Liquid Under High-Pressure
    Hornak, S.
    LATEST METHODS OF CONSTRUCTION DESIGN, 2016, : 139 - 143
  • [26] MASS TRANSFER IN SOLID-LIQUID EXTRACTION AT HIGH SOLUTE CONCENTRATIONS
    Popa, Marcela
    Tudose, Eugenia Teodora Iacob
    Mamaliga, Ioan
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2018, 17 (04): : 827 - 839
  • [27] Mass transfer dynamics during high pressure brining of chicken breast
    Leng, XueJiao
    Zhang, Lin
    Huang, Ming
    Xu, XingLian
    Zhou, GuangHong
    JOURNAL OF FOOD ENGINEERING, 2013, 118 (03) : 296 - 301
  • [28] MEASUREMENT AND CORRELATION OF THE MASS TRANSFER COEFFICIENT FOR A LIQUID-LIQUID SYSTEM WITH HIGH DENSITY DIFFERENCE
    Huang, Zhixian
    Ye, Changshen
    Li, Ling
    Zhang, Xiaowu
    Qiu, Ting
    BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2016, 33 (04) : 897 - 906
  • [29] The impact of pressure and frictional heating on retention, selectivity and efficiency in ultra-high-pressure liquid chromatography
    McCalley, David V.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 63 : 31 - 43
  • [30] In situ viscometry of high-pressure melts in the Paris-Edinburgh cell: application to liquid FeS
    Perrillat, Jean-Philippe
    Mezouar, Mohamed
    Garbarino, Gaston
    Bauchau, Stany
    HIGH PRESSURE RESEARCH, 2010, 30 (03) : 415 - 423