Real -time biomonitoring of oxygen uptake rate and biochemical oxygen demand using a novel optical biogas respirometric system

被引:18
作者
Hussain, Fida [1 ]
Yu, Hye-Weon [2 ]
Chon, Kangmin [3 ]
Lee, Yong-Gu [3 ]
Eom, Heonseop [1 ]
Chae, Kyu-Jung [4 ]
Oh, Sang-Eun [1 ]
机构
[1] Kangwon Natl Univ, Dept Biol Environm, 192-1 Hyoja Dong, Gangwon Do 200701, Chuncheon Si, South Korea
[2] K Water Inst, Daejeon 34350, South Korea
[3] Kangwon Natl Univ, Coll Art Culture & Engn, Dept Environm Engn, 1 Kangwondaehak Gil, Chuncheon Si 24341, Gangwon Do, South Korea
[4] Korea Maritime & Ocean Univ, Dept Environm Engn, 727 Taejong Ro, Busan 49112, South Korea
关键词
Respirometer; Biochemical oxygen demand (BOD); Oxygen uptake rate (OUR); Real-time monitoring; WASTE-WATER; BOD;
D O I
10.1016/j.jenvman.2020.111467
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In response to the ever-increasing need for monitoring-based process control of wastewater treatment plants, an online applicable respirometer shows great promise for real-time measurement of oxygen uptake rate (OUR) and biochemical oxygen demand (BOD) measurements as a surrogate of the biodegradability of wastewater. Here, we have developed a photosensor-assisted real-time respirometric system equipped with bubble counting sensors for accurate measurement of microbial oxygen consumption in a bottle. This system can measure OUR and BOD in a bottle equipped with a tube containing NaOH solution to absorb carbon dioxide and supplied with continuous atmospheric oxygen to the bottle, which reliably supplies non-limiting dissolved oxygen (DO) for aerobic biodegradation even at high organic loads. These technical improvements allow a sensitive and rapid analytical tool offering real-time profiles of oxygen uptake rate as well as BOD measurements with an extended measurable range (0-420 mg O-2/L), enabling significant reduction or elimination of dilution steps. The respirometric system was used to elucidate the biodegradable kinetics of domestic and swine wastewaters as a function of the type and concentration of organic matters, depending on source characteristics including rapidly or slowly oxidizable organic substances by bacteria. Compared with conventional and manometric BOD methods, our method is reliable and accurate.
引用
收藏
页数:7
相关论文
共 16 条
[1]  
[Anonymous], 2015, CHALLENGE AER 200
[2]  
AWWA W, 2012, STANDARD METHODS EXA, DOI [10.5209/rev_ANHM.2012.v5.n2.40440, DOI 10.5209/REV_ANHM.2012.V5.N2.40440]
[3]   The increasing importance of assessing toxicity in determining sludge health and management policy [J].
Davies, PS ;
Murdoch, F .
MEASUREMENT & CONTROL, 2002, 35 (08) :238-242
[4]  
EPA, 1998, TEST SHAK FLASK AW F
[5]  
Gruiz K., 2017, Engineering Tools for Environmental Risk Management: 3. Site Assessment and Monitoring Tools
[6]   Activated sludge inhibition by chemical stressors - A comprehensive study [J].
Henriques, Ines D. S. ;
Kelly, Richard T., II ;
Dayphinais, Jennifer L. ;
Love, Nancy G. .
WATER ENVIRONMENT RESEARCH, 2007, 79 (09) :940-951
[7]   Methods for assessing biochemical oxygen demand (BOD): A review [J].
Jouanneau, S. ;
Recoules, L. ;
Durand, M. J. ;
Boukabache, A. ;
Picot, V. ;
Primault, Y. ;
Lakel, A. ;
Sengelin, M. ;
Barillon, B. ;
Thouand, G. .
WATER RESEARCH, 2014, 49 :62-82
[8]   A reagent-free tubular biofilm reactor for on-line determination of biochemical oxygen demand [J].
Liu, Changyu ;
Zhao, Huijun ;
Gao, Shan ;
Jia, Jianbo ;
Zhao, Limin ;
Yong, Daming ;
Dong, Shaojun .
BIOSENSORS & BIOELECTRONICS, 2013, 45 :213-218
[9]  
McKinney RossE., 2004, Environmental Pollution Control and Microbiology
[10]   GLOSSARY FOR CHEMISTS OF TERMS USED IN BIOTECHNOLOGY - (IUPAC RECOMMENDATIONS 1992) [J].
NAGEL, B ;
DELLWEG, H ;
GIERASCH, LM .
PURE AND APPLIED CHEMISTRY, 1992, 64 (01) :143-168