Duplex ultrasonography in assessing restenosis of renal artery stents

被引:31
作者
Bakker, J [1 ]
Beutler, JJ [1 ]
Elgersma, OEH [1 ]
de Lange, EE [1 ]
de Kort, GAP [1 ]
Beek, FJA [1 ]
机构
[1] Univ Utrecht Hosp, Dept Radiol, NL-3584 CX Utrecht, Netherlands
关键词
renal arteries; stenosis or obstruction; stents and prostheses; duplex ultrasonography;
D O I
10.1007/s002709900435
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To determine the accuracy and optimal threshold values of duplex ultrasonography (US) in assessing restenosis of renal artery stents. Methods: Twenty-four consecutive patients with 33 renal arteries that had previously been treated with placement of a Palmaz stent underwent duplex US prior to intraarterial digital subtraction angiography (DSA), which was the reference standard. Diagnostic accuracy of in-stent peak systolic velocity (PSV) and reno-aortic ratio (RAR = PSV renal stent/PSV aorta) in detecting > 50% in-stent restenosis were evaluated by the receiver operating characteristic curve. Sensitivity and specificity were determined using the optimal threshold values, and using published threshold values: RAR > 3.5 and in-stent PSV > 180 cm/sec. Results: Six examinations were technically inadequate. Nine stents had residual or restenosis > 50% at DSA. The two duplex parameters were equally accurate since areas under the curves were similar (0.943). With optimal threshold values of 226 cm/sec for PSV and 2.7 for RAR, sensitivities and specificities were 100% and 90%, and 100% and 84%, respectively. Using the published duplex criteria resulted in sensitivities and specificities of 100% and 74% for PSV, and 50% and 89% for RAR. Conclusion: Duplex US is a sensitive modality for detecting in-stent restenosis if laboratory-specific threshold values are used.
引用
收藏
页码:475 / 480
页数:6
相关论文
共 43 条
[31]   PALMAZ STENT IN ATHEROSCLEROTIC STENOSES INVOLVING THE OSTIA OF THE RENAL-ARTERIES - PRELIMINARY-REPORT OF A MULTICENTER STUDY [J].
REES, CR ;
PALMAZ, JC ;
BECKER, GJ ;
EHRMAN, KO ;
RICHTER, GM ;
NOELDGE, G ;
KATZEN, BT ;
DAKE, MD ;
SCHWARTEN, DE .
RADIOLOGY, 1991, 181 (02) :507-514
[32]   Percutaneous renal artery stent placement for hypertension and azotemia: Pilot study [J].
Rundback, JH ;
Jacobs, JM .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1996, 28 (02) :214-219
[33]   Restenosis of peripheral stents and stent grafts as revealed by intravascular sonography:: In vivo comparison with angiography [J].
Schwarzenberg, H ;
Müller-Hülsbeck, S ;
Glüer, CC ;
Wesner, F ;
Heller, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (05) :1181-1185
[34]   PERCUTANEOUS TRANS-LUMINAL RENAL ANGIOPLASTY IN RENOVASCULAR HYPERTENSION DUE TO ATHEROMA OR FIBROMUSCULAR DYSPLASIA [J].
SOS, TA ;
PICKERING, TG ;
SNIDERMAN, K ;
SADDEKNI, S ;
CASE, DB ;
SILANE, MF ;
VAUGHAN, ED ;
LARAGH, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 1983, 309 (05) :274-279
[35]   DUPLEX IMAGING FOR THE DETECTION OF RENAL-ARTERY STENOSIS [J].
STRANDNESS, DE .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1994, 24 (04) :674-678
[36]  
STROTZER M, 1995, ACTA RADIOL, V36, P243
[37]   Stent placement after iliac angioplasty: Comparison of hemodynamic and angiographic criterial [J].
Tetteroo, E ;
vanEngelen, AD ;
Spithoven, JH ;
Tielbeek, AV ;
vanderGraaf, Y ;
Mali, WPTM .
RADIOLOGY, 1996, 201 (01) :155-159
[38]   Results of percutaneous transluminal angioplasty for atherosclerotic renal artery stenosis: A follow-up study with duplex ultrasonography [J].
Tullis, MJ ;
Zierler, RE ;
Glickerman, DJ ;
Bergelin, RO ;
CantwellGab, K ;
Strandness, DE .
JOURNAL OF VASCULAR SURGERY, 1997, 25 (01) :46-54
[39]   Arterial stenting and balloon angioplasty in ostial atherosclerotic renovascular disease: a randomised trial [J].
van de Ven, PJG ;
Kaatee, R ;
Beutler, JJ ;
Beek, FJA ;
Woittiez, AJJ ;
Buskens, E ;
Koomans, HA ;
Mali, WPT .
LANCET, 1999, 353 (9149) :282-286
[40]   TRANSLUMINAL VASCULAR STENT FOR OSTIAL ATHEROSCLEROTIC RENAL-ARTERY STENOSIS [J].
VANDEVEN, PJG ;
BEUTLER, JJ ;
KAATEE, R ;
BEEK, FJA ;
MALI, WPTM ;
GEYSKES, GG ;
KOOMANS, HA .
LANCET, 1995, 346 (8976) :672-674