Duplex ultrasonography in assessing restenosis of renal artery stents

被引:31
作者
Bakker, J [1 ]
Beutler, JJ [1 ]
Elgersma, OEH [1 ]
de Lange, EE [1 ]
de Kort, GAP [1 ]
Beek, FJA [1 ]
机构
[1] Univ Utrecht Hosp, Dept Radiol, NL-3584 CX Utrecht, Netherlands
关键词
renal arteries; stenosis or obstruction; stents and prostheses; duplex ultrasonography;
D O I
10.1007/s002709900435
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To determine the accuracy and optimal threshold values of duplex ultrasonography (US) in assessing restenosis of renal artery stents. Methods: Twenty-four consecutive patients with 33 renal arteries that had previously been treated with placement of a Palmaz stent underwent duplex US prior to intraarterial digital subtraction angiography (DSA), which was the reference standard. Diagnostic accuracy of in-stent peak systolic velocity (PSV) and reno-aortic ratio (RAR = PSV renal stent/PSV aorta) in detecting > 50% in-stent restenosis were evaluated by the receiver operating characteristic curve. Sensitivity and specificity were determined using the optimal threshold values, and using published threshold values: RAR > 3.5 and in-stent PSV > 180 cm/sec. Results: Six examinations were technically inadequate. Nine stents had residual or restenosis > 50% at DSA. The two duplex parameters were equally accurate since areas under the curves were similar (0.943). With optimal threshold values of 226 cm/sec for PSV and 2.7 for RAR, sensitivities and specificities were 100% and 90%, and 100% and 84%, respectively. Using the published duplex criteria resulted in sensitivities and specificities of 100% and 74% for PSV, and 50% and 89% for RAR. Conclusion: Duplex US is a sensitive modality for detecting in-stent restenosis if laboratory-specific threshold values are used.
引用
收藏
页码:475 / 480
页数:6
相关论文
共 43 条
[1]   Grading carotid stenosis with ultrasound - An interlaboratory comparison [J].
Alexandrov, AV ;
Vital, D ;
Brodie, DS ;
Hamilton, P ;
Grotta, JC .
STROKE, 1997, 28 (06) :1208-1210
[2]  
[Anonymous], 1987, ARCH INTERN MED, V147, P820
[3]   RENAL-ARTERY STENOSIS - PROSPECTIVE EVALUATION OF DIAGNOSIS WITH COLOR DUPLEX US COMPARED WITH ANGIOGRAPHY - WORK IN PROGRESS [J].
BERLAND, LL ;
KOSLIN, DB ;
ROUTH, WD ;
KELLER, FS .
RADIOLOGY, 1990, 174 (02) :421-423
[4]   Treatment of ostial renal-artery stenoses with vascular endoprostheses after unsuccessful balloon angioplasty [J].
Blum, U ;
Krumme, B ;
Flugel, P ;
Gabelmann, A ;
Lehnert, T ;
BuitragoTellez, C ;
Schollmeyer, P ;
Langer, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (07) :459-465
[5]   PULSUS TARDUS - ITS CAUSE AND POTENTIAL LIMITATIONS IN DETECTION OF ARTERIAL-STENOSIS [J].
BUDE, RO ;
RUBIN, JM ;
PLATT, JF ;
FECHNER, KP ;
ADLER, RS .
RADIOLOGY, 1994, 190 (03) :779-784
[6]   PERCUTANEOUS TRANS-LUMINAL RENAL ANGIOPLASTY IN MANAGEMENT OF ATHEROSCLEROTIC RENOVASCULAR HYPERTENSION - RESULTS IN 100 PATIENTS [J].
CANZANELLO, VJ ;
MILLAN, VG ;
SPIEGEL, JE ;
PONCE, SP ;
KOPELMAN, RI ;
MADIAS, NE .
HYPERTENSION, 1989, 13 (02) :163-172
[7]   RENAL-ARTERY STENOSIS - ANATOMIC CLASSIFICATION FOR PERCUTANEOUS TRANS-LUMINAL ANGIOPLASTY [J].
CICUTO, KP ;
MCLEAN, GK ;
OLEAGA, JA ;
FREIMAN, DB ;
GROSSMAN, RA ;
RING, EJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (03) :599-601
[8]  
Daigle RJ, 1990, J VASC TECHNOL, V14, P206
[9]   RENAL-ARTERY STENOSIS - EVALUATION WITH COLOR DOPPLER FLOW IMAGING [J].
DESBERG, AL ;
PAUSHTER, DM ;
LAMMERT, GK ;
HALE, JC ;
TROY, RB ;
NOVICK, AC ;
NALLY, JV ;
WELTEVREDEN, AM .
RADIOLOGY, 1990, 177 (03) :749-753
[10]   INTRAVASCULAR ULTRASONOGRAPHY BEFORE AND AFTER INTERVENTION - IN-VIVO COMPARISON WITH ANGIOGRAPHY [J].
GERRITSEN, GP ;
GUSSENHOVEN, EJ ;
THE, SHK ;
PIETERMAN, H ;
VANDERLUGT, A ;
LI, WG ;
BOM, N ;
VANDIJK, LC ;
DUBOIS, NAJJ ;
VANURK, H .
JOURNAL OF VASCULAR SURGERY, 1993, 18 (01) :31-40