The lateral-flow immunoassay (LFA) is an inexpensive point-of-care (POC) paper-based diagnostic device with the potential to rapidly detect disease biomarkers in resource-poor settings. Although LFA is inexpensive, easy to use, and requires no laboratory equipment, it is limited by its sensitivity, which remains inferior to that of gold standard laboratory-based assays. Our group is the only one to have previously utilized various aqueous two-phase systems (ATPSs) to enhance LFA detection. In those studies, the sample was concentrated by an ATPS in a test tube and could only be applied to LFA after it had been extracted manually. Here, we bypass the extraction step by seamlessly integrating a polyethylene glycol-potassium phosphate ATPS with downstream LFA detection in a simple, inexpensive, power-free, and portable all-in-one diagnostic device. We discovered a new phenomenon in which the target biomarkers simultaneously concentrate as the ATPS solution flows through the paper membranes, and our device features a 3-D paper well that was designed to exploit this phenomenon. Studies with this device, which were performed at room temperature in under 25 min, demonstrated a 10-fold improvement in the detection limit of a model protein, transferrin. Our next-generation LFA technology is rapid, affordable, easy-to-use, and can be applied to existing LFA products, thereby providing a new platform for revolutionizing the current state of disease diagnosis in resource-poor settings.
引用
收藏
页码:3021 / 3028
页数:8
相关论文
共 18 条
[11]   Enhancing the lateral-flow immunoassay for viral detection using an aqueous two-phase micellar system [J].
Mashayekhi, Foad ;
Chiu, Ricky Y. T. ;
Le, Alexander M. ;
Chao, Felix C. ;
Wu, Benjamin M. ;
Kamei, Daniel T. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (7-8) :2955-2961
[12]   Size correlation of optical and spectroscopic properties for gold nanoparticles [J].
Njoki, Peter N. ;
Lim, I-Im S. ;
Mott, Derrick ;
Park, Hye-Young ;
Khan, Bilal ;
Mishra, Suprav ;
Sujakumar, Ravishanker ;
Luo, Jin ;
Zhong, Chuan-Jian .
JOURNAL OF PHYSICAL CHEMISTRY C, 2007, 111 (40) :14664-14669
[13]   Fluidic Timers for Time-Dependent, Point-of-Care Assays on Paper [J].
Noh, Hyeran ;
Phillips, Scott T. .
ANALYTICAL CHEMISTRY, 2010, 82 (19) :8071-8078
[14]   Metering the Capillary-Driven Flow of Fluids in Paper-Based Microfluidic Devices [J].
Noh, Nyeran ;
Phillips, Scott T. .
ANALYTICAL CHEMISTRY, 2010, 82 (10) :4181-4187
[15]   Microfluidics without pumps: reinventing the T-sensor and H-filter in paper networks [J].
Osborn, Jennifer L. ;
Lutz, Barry ;
Fu, Elain ;
Kauffman, Peter ;
Stevens, Dean Y. ;
Yager, Paul .
LAB ON A CHIP, 2010, 10 (20) :2659-2665
[16]   Laboratory medicine in Africa: A barrier to effective health care [J].
Petti, CA ;
Polage, CR ;
Quinn, TC ;
Ronald, AR ;
Sande, MA .
CLINICAL INFECTIOUS DISEASES, 2006, 42 (03) :377-382
[17]   Point-of-care diagnostics for global health [J].
Yager, Paul ;
Domingo, Gonzalo J. ;
Gerdes, John .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2008, 10 :107-144
[18]   Microfluidic diagnostic technologies for global public health [J].
Yager, Paul ;
Edwards, Thayne ;
Fu, Elain ;
Helton, Kristen ;
Nelson, Kjell ;
Tam, Milton R. ;
Weigl, Bernhard H. .
NATURE, 2006, 442 (7101) :412-418