Performance Evaluation of Stationary and Semi-Stationary Acquisition with a Non-Stationary Small Animal Multi-Pinhole SPECT System

被引:13
|
作者
Lange, Catharina [1 ]
Apostolova, Ivayla [1 ]
Lukas, Mathias [1 ]
Huang, Kai P. [1 ]
Hofheinz, Frank [2 ]
Gregor-Mamoudou, Betina [1 ]
Brenner, Winfried [1 ]
Buchert, Ralph [1 ]
机构
[1] Charite, Dept Nucl Med, D-10117 Berlin, Germany
[2] Helmholtz Zentrum Dresden Rossendorf, PET Ctr, Inst Radiopharmaceut Canc Res, D-01328 Dresden, Germany
关键词
SPECT; Dynamic imaging; Stationary; Performance evaluation; RENAL-FUNCTION; QUANTIFICATION;
D O I
10.1007/s11307-013-0702-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Step-and-shoot mode with many angular steps results in long frame duration limiting the capability of single-photon emission computed tomography (SPECT) for fast dynamic scans. The present study evaluates acquisition with reduced angular sampling for fast imaging in preclinical research with the nanoSPECT/CTplus four-head multi-pinhole system. Measurements with line sources, homogeneity phantoms and a Jaszczak phantom filled with Tc-99m or I-123 were performed to evaluate the 'stationary' and 'semi-stationary' acquisition mode (one or two detector positions, respectively) with respect to spatial resolution, quantification, noise properties and image artefacts. An in vivo mouse study was performed with Tc-99m-MAG3. The fast acquisition modes resulted in only minor degradation of spatial resolution and quantification accuracy. Statistical noise in reconstructed images was significantly reduced compared to conventional SPECT, particularly at low count statistics. Stationary acquisition resulted in streak artefacts and spatial distortion. The semi-stationary acquisition mode of the nanoSPECT/CTplus allows fast dynamic SPECT with tolerable loss of image quality.
引用
收藏
页码:311 / 316
页数:6
相关论文
共 50 条
  • [21] Performance evaluation of fifth-generation ultra-high-resolution SPECT system with two stationary detectors and multi-pinhole imaging
    Jan V. Hoffmann
    Jan P. Janssen
    Takayuki Kanno
    Takayuki Shibutani
    Masahisa Onoguchi
    Constantin Lapa
    Jan-Peter Grunz
    Andreas K. Buck
    Takahiro Higuchi
    EJNMMI Physics, 7
  • [22] Simulation study on a stationary data acquisition SPECT system with multi-pinhole collimators attached to a triple-head gamma camera system
    Ogawa, Koichi
    Ichimura, Yuta
    ANNALS OF NUCLEAR MEDICINE, 2014, 28 (08) : 716 - 724
  • [23] SPECT Data Acquisition and Image Reconstruction in a Stationary Small Animal SPECT/MRI System
    Xu, Jingyan
    Chen, Si
    Yu, Jianhua
    Meier, Dirk
    Wagenaar, Douglas J.
    Patt, Bradley E.
    Tsui, Benjamin M. W.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [24] Simulation study on a stationary data acquisition SPECT system with multi-pinhole collimators attached to a triple-head gamma camera system
    Koichi Ogawa
    Yuta Ichimura
    Annals of Nuclear Medicine, 2014, 28 : 716 - 724
  • [25] Image Reconstructions from Limit Views and Angle Coverage Data for a Stationary Multi-Pinhole SPECT System
    HSIEH Hohui
    HSIAO Ingtsung
    Tsinghua Science and Technology, 2010, 15 (01) : 44 - 49
  • [26] Small animal imaging with multi-pinhole SPECT
    Nuyts, Johan
    Vunckx, Kathleen
    Defrise, Michel
    Vanhove, Christian
    METHODS, 2009, 48 (02) : 83 - 91
  • [27] Performance evaluation of a novel multi-pinhole SPECT system
    Jiang, Nianming
    Liu, Hui
    Xue, Mengle
    Li, Cheng
    Gao, Lilei
    Liu, Fan
    Wu, Jing
    Liu, Yaqiang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1059
  • [28] On the performance of two multi-pinhole SPECT systems for small animal research
    Schramm, NU
    Lackas, C
    Hoppin, J
    Schurrat, T
    Béhé, M
    Engeland, U
    Behr, TA
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2823 - 2824
  • [29] Multi-pinhole SPECT for small animal research.
    Schramm, NU
    Engeland, U
    Ebel, G
    Schurrat, T
    Behe, M
    Behr, TM
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 223P - 223P
  • [30] Optimization of a stationary small animal SPECT system for simultaneous SPECT/MRI
    Van Holen, Roe
    Vandenberghe, Stefaan
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,