摘要
Step-and-shoot mode with many angular steps results in long frame duration limiting the capability of single-photon emission computed tomography (SPECT) for fast dynamic scans. The present study evaluates acquisition with reduced angular sampling for fast imaging in preclinical research with the nanoSPECT/CTplus four-head multi-pinhole system. Measurements with line sources, homogeneity phantoms and a Jaszczak phantom filled with Tc-99m or I-123 were performed to evaluate the 'stationary' and 'semi-stationary' acquisition mode (one or two detector positions, respectively) with respect to spatial resolution, quantification, noise properties and image artefacts. An in vivo mouse study was performed with Tc-99m-MAG3. The fast acquisition modes resulted in only minor degradation of spatial resolution and quantification accuracy. Statistical noise in reconstructed images was significantly reduced compared to conventional SPECT, particularly at low count statistics. Stationary acquisition resulted in streak artefacts and spatial distortion. The semi-stationary acquisition mode of the nanoSPECT/CTplus allows fast dynamic SPECT with tolerable loss of image quality.
引用
收藏
页码:311 / 316
页数:6
相关论文
共 50 条
  • [1] Performance Evaluation of Stationary and Semi-Stationary Acquisition with a Non-Stationary Small Animal Multi-Pinhole SPECT System
    Catharina Lange
    Ivayla Apostolova
    Mathias Lukas
    Kai P. Huang
    Frank Hofheinz
    Betina Gregor-Mamoudou
    Winfried Brenner
    Ralph Buchert
    Molecular Imaging and Biology, 2014, 16 : 311 - 316
  • [2] Evaluation of Stationary and Semi-stationary Acquisitions in a Dual-head Multi-pinhole System for Myocardial Perfusion SPECT
    Yan, Pengyu
    Mok, Greta S. P.
    Chen, Ling
    Tsui, Benjamin M. W.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [3] Evaluation of Stationary and Semi-stationary Acquisitions from Dual-head Multi-pinhole Collimator for Myocardial Perfusion SPECT
    Yan, Pengyu
    Chen, Ling
    Tsui, Benjamin M. W.
    Mok, Greta S. P.
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2016, 36 (05) : 675 - 685
  • [4] Evaluation of Stationary and Semi-stationary Acquisitions from Dual-head Multi-pinhole Collimator for Myocardial Perfusion SPECT
    Pengyu Yan
    Ling Chen
    Benjamin M. W. Tsui
    Greta S. P. Mok
    Journal of Medical and Biological Engineering, 2016, 36 : 675 - 685
  • [5] Performance Evaluation on reconstructions in a Stationary Multi-pinhole SPECT
    Hsieh, Ho-Hui
    Lin, Kun-Ju
    Hsu, Chin-Han
    Hsiao, Ing-Tsung
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3777 - +
  • [6] Simulation Study on a Stationary SPECT System With Multi-pinhole Collimators
    Kubota, Hayao
    Motomura, Nobutoku
    Ogawa, Koichi
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [7] Design of a Multi-Pinhole Collimator in a Dual-Headed, Stationary, Small-Animal SPECT
    Shokouhi, S.
    Fritz, M. A.
    McDonald, B. S.
    Wilson, D. W.
    Metzler, S. D.
    Peterson, T. E.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2399 - 2402
  • [8] Performance of a Novel Small-Animal SPECT System with Two Stationary Detectors: A Comparison of Multi-Pinhole Collimators for Mouse Imaging
    Hoffmann, J.
    Janssen, J.
    Kanno, T.
    Higuchi, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S453 - S453
  • [9] Performance Evaluation of stationary dedicated cardiac SPECT with multi-pinhole collimators: Comparison with conventional SPECT and CZT SPECT
    Wang, Haipeng
    Guo, Feng
    Wang, Xinqiang
    Zhang, Zongyao
    Wang, Daoyu
    Xu, Yingying
    Liu, Yaqiang
    Chen, Si
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [10] A SEMI-STATIONARY CT SYSTEM
    Chen, Yi
    Xi, Yan
    Zhao, Jun
    2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI), 2014, : 1099 - 1102