Energy, exergy, and economic analysis of single and double effect LiBr-H2O absorption chillers

被引:76
作者
Avanessian, T. [1 ,2 ]
Ameri, M. [1 ,2 ]
机构
[1] Shahid Bahonar Univ, Fac Engn, Dept Mech Engn, Kerman, Iran
[2] Shahid Bahonar Univ, Energy & Environm Engn Res Ctr, Kerman, Iran
关键词
Absorption refrigeration system; Counter-flow wet cooling tower; Boiler; Exergy; Second law efficiency; WATER; PERFORMANCE; SYSTEM;
D O I
10.1016/j.enbuild.2014.01.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study different water-cooled LiBr-H2O absorption systems under different operating and climatic conditions are analyzed and compared, and the effect of considering the chemical exergy of the LiBr-H2O solution on the second law analysis of such systems is probed as well. Results show that the EUF increases with increasing the generator and evaporator temperatures and decreases with the increase in the temperature and relative humidity of the ambient air. The total exergy efficiency increases with increasing the generator or ambient air temperature, decreases with increasing the evaporator temperature, and changes slightly with relative humidity. In T-amb =35 C and phi = 30%, the system including direct-fired double-effect chiller has a EUF = 1.20 and psi = 7.86% both of which are respectively 11% and 82% higher than the systems including hot-water double-effect and single-effect chillers. The economic analysis reveals that for the operating conditions presented here, the single-effect system is uneconomical and the payback period in the case of utilizing the direct-fired double-effect chiller instead of the hot-water one is about 3.5 years. Finally, the CO2 emission of the single-effect system is respectively about 1.9 and 1.7 times higher than direct-fired and hot-water double-effect ones. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:26 / 36
页数:11
相关论文
共 27 条
[1]  
[Anonymous], 2007, 3LSEVIER SCI
[2]  
[Anonymous], 2008, BROAD X ADSORPTION C
[3]   Experimental validation of a fully solar-driven triple-state absorption system in small residential buildings [J].
Borge-Diez, David ;
Colmenar-Santos, Antonio ;
Perez-Molina, Clara ;
Castro-Gil, Manuel .
ENERGY AND BUILDINGS, 2012, 55 :227-237
[4]  
Cengel Y.A., 2005, Thermodynamics: An Engineering Approach, V5th
[5]   Analysis of sectoral energy and exergy use of Saudi Arabia [J].
Dincer, I ;
Hussain, MM ;
Al-Zaharnah, I .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2004, 28 (03) :205-243
[6]   Analysis of crystallization risk in double effect absorption refrigeration systems [J].
Farshi, L. Garousi ;
Mahmoudi, S. M. Seyed ;
Rosen, M. A. .
APPLIED THERMAL ENGINEERING, 2011, 31 (10) :1712-1717
[7]   Second law analysis of double effect vapour absorption cooler system [J].
Gomri, Rabah ;
Hakimi, Riad .
ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (11) :3343-3348
[8]   Second law comparison of single effect and double effect vapour absorption refrigeration systems [J].
Gomri, Rabah .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (05) :1279-1287
[9]   Experimental exergetic performance evaluation of a novel solar assisted LiCl-H2O absorption cooling system [J].
Gunhan, Tuncay ;
Ekren, Orhan ;
Demir, Vedat ;
Hepbasli, Arif ;
Erek, Aytunc ;
Sahin, Arzu Sencan .
ENERGY AND BUILDINGS, 2014, 68 :138-146
[10]   Potential energy benefits of integrated refrigeration system with microturbine and absorption chiller [J].
Hwang, YH .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (08) :816-829