Cerebral Blood Flow Quantification in Swine Using Pseudo-Continuous Arterial Spin Labeling

被引:3
作者
Johnston, Megan E. [1 ]
Zheng, Zhenlin [1 ]
Maldjian, Joseph A. [1 ]
Whitlow, Christopher T. [1 ]
Morykwas, Michael J. [1 ]
Jung, Youngkyoo [1 ]
机构
[1] Wake Forest Sch Med, Winston Salem, NC USA
关键词
animal model; arterial transit time; cerebral blood flow; pseudo-continuous arterial spin labeling; perfusion; POSITRON-EMISSION-TOMOGRAPHY; MAGNETIC-RESONANCE; PERFUSION CT; QUIPSS II; MODEL; TIME; MRI; INVERSION; VALUES; SPACE;
D O I
10.1002/jmri.24066
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop quantitative cerebral blood flow (CBF) imaging using pseudo-continuous arterial spin labeling (PCASL) in swine, accounting for their cerebrovascular anatomy and physiology. Materials and MethodsFive domestic pigs (2.5-3 months, 25 kg) were used in these studies. The orientation of the labeled arteries, T-1bl, M-0bl, and T-1gm were measured in swine. Labeling parameters were tuned with respect to blood velocity to optimize labeling efficiency based on the data collected from three subjects. Finally, CBF and arterial transit time (ATT) maps for two subjects were created from PCASL data to determine global averages. ResultsThe average labeling efficiency over measured velocities of 5-18 cm/s was 0.930. The average T-1bl was 1546 ms, the average T-1gm was 1224 ms, and the average blood-to-white matter ratio of M-0 was 1.25, which was used to find M-0bl. The global averages over the subjects were 54.05 mL/100 g tissue/min CBF and 1261 ms ATT. ConclusionThis study demonstrates the feasibility of PCASL for CBF quantification in swine. Quantification of CBF using PCASL in swine can be further developed as an accessible and cost-effective model of human cerebral perfusion for investigating injuries that affect blood flow. J. Magn. Reson. Imaging 2013;38:1111-1118. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1111 / 1118
页数:8
相关论文
共 41 条
  • [1] Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow
    Alsop, DC
    Detre, JA
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1996, 16 (06) : 1236 - 1249
  • [2] Pig brain stereotaxic standard space: Mapping of cerebral blood flow normative values and effect of MPTP-lesioning
    Andersen, F
    Watanabe, H
    Bjarkam, CB
    Danielsen, EH
    Cumming, P
    [J]. BRAIN RESEARCH BULLETIN, 2005, 66 (01) : 17 - 29
  • [3] Burbridge B, 2004, CAN ASSOC RADIOL J, V55, P326
  • [4] A general kinetic model for quantitative perfusion imaging with arterial spin labeling
    Buxton, RB
    Frank, LR
    Wong, EC
    Siewert, B
    Warach, S
    Edelman, RR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) : 383 - 396
  • [5] Absolute quantification of cerebral blood flow with magnetic resonance, reproducibility of the method, and comparison with H215O positron emission tomography
    Carroll, TJ
    Teneggi, V
    Jobin, M
    Squassante, L
    Treyer, V
    Hany, TF
    Burger, C
    Wang, L
    Bye, T
    von Schulthess, GK
    Buck, A
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2002, 22 (09) : 1149 - 1156
  • [6] Magnetic resonance perfusion imaging in acute ischemic stroke using continuous arterial spin labeling
    Chalela, JA
    Alsop, DC
    Gonzalez-Atavales, JB
    Maldjian, JA
    Kasner, SE
    Detre, JA
    [J]. STROKE, 2000, 31 (03) : 680 - 687
  • [7] Test-Retest Reliability of Arterial Spin Labeling With Common Labeling Strategies
    Chen, Yufen
    Wang, Danny J. J.
    Detre, John A.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (04) : 940 - 949
  • [8] Continuous Flow-Driven Inversion for Arterial Spin Labeling Using Pulsed Radio Frequency and Gradient Fields
    Dai, Weiying
    Garcia, Dairon
    de Bazelaire, Cedric
    Alsop, David C.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) : 1488 - 1497
  • [9] STUDIES OF THE CAROTID RETE AND ITS ASSOCIATED ARTERIES
    DANIEL, PM
    DAWES, JDK
    PRICHARD, MML
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES B-BIOLOGICAL SCIENCES, 1953, 237 (645) : 173 - &
  • [10] PERFUSION IMAGING
    DETRE, JA
    LEIGH, JS
    WILLIAMS, DS
    KORETSKY, AP
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) : 37 - 45