An affordable custom phantom for measurement of linac time delay in gated treatments with irregular breathing
被引:5
|
作者:
Santos, Alexandre M. Caraca
论文数: 0引用数: 0
h-index: 0
机构:
Royal Adelaide Hosp, Dept Med Phys, Adelaide, SA, Australia
Univ Adelaide, Sch Phys Sci, Adelaide, SA, AustraliaRoyal Adelaide Hosp, Dept Med Phys, Adelaide, SA, Australia
Santos, Alexandre M. Caraca
[1
,2
]
Shepherd, Justin
论文数: 0引用数: 0
h-index: 0
机构:
Royal Adelaide Hosp, Dept Med Phys, Adelaide, SA, AustraliaRoyal Adelaide Hosp, Dept Med Phys, Adelaide, SA, Australia
Shepherd, Justin
[1
]
机构:
[1] Royal Adelaide Hosp, Dept Med Phys, Adelaide, SA, Australia
[2] Univ Adelaide, Sch Phys Sci, Adelaide, SA, Australia
Respiratory gating;
Motion phantom;
Time delay;
QUALITY-ASSURANCE;
ACCURACY;
CANCER;
D O I:
10.1007/s13246-019-00785-y
中图分类号:
R318 [生物医学工程];
学科分类号:
0831 ;
摘要:
Respiratory gated treatments are now common in order to reduce tumour motion uncertainties due to breathing. One issue associated with gated treatments is the time delay between the gating system and the linear accelerator. In this study we develop and characterise an affordable phantom to be used in routine and patient specific quality assurance (QA) of the Varian Real-Time Position Management (TM) (RPM) system. A photodiode has been incorporated into the phantom in order to estimate the time delay. A commercial Quasar phantom was customised to incorporate two stepper motors which independently control an anterior-posterior abdomen/thorax moving plate, and an inferior-superior moving lung insert. A photodiode placed in the path of the radiation is used to measure when beam on/off occurs. Two Arduino microcontroller boards have been utilised to control the motors, read the photodiode and write to an SD card. The measured beam on/off, correlated to the known positions of the phantom is compared to the gate window for RPM. The time delay was measured for sinusoidal movements with a period of 7.50 s and 3.75 s, and for three patient breathing traces. For the sinusoidal movements, time delays of 150 +/- 34 ms and 39 +/- 34 ms were measured, for 7.50 s and 3.75 s periods, respectively. In the case of the patients' breathing traces time delays of 135 +/- 26 ms, 137 +/- 34 ms and 129 +/- 28 ms were measured. An affordable motion phantom has been developed for routine and patient specific QA of respiratory gating systems. It is capable of reproducing a patient's breathing waveform and performing time delay measurements with a photodiode. Results indicate a time delay of the order of 0.1-0.2 s for the RPM system.
机构:
Tom Baker Canc Clin, Dept Med Phys, 1331 29th St NW, Calgary, AB T2N4N2, CanadaTom Baker Canc Clin, Dept Med Phys, 1331 29th St NW, Calgary, AB T2N4N2, Canada
Goharian, M.
Khan, R. F. H.
论文数: 0引用数: 0
h-index: 0
机构:
Tom Baker Canc Clin, Dept Med Phys, 1331 29th St NW, Calgary, AB T2N4N2, Canada
Univ Calgary, Dept Oncol Phys & Astron, Calgary, AB, CanadaTom Baker Canc Clin, Dept Med Phys, 1331 29th St NW, Calgary, AB T2N4N2, Canada
机构:
Univ Paris Saclay, Fac Med, F-94276 Le Kremlin Bicetre, France
Sorbonne Univ, Tenon Hosp, AP HP, Dept Radiat Oncol, F-75020 Paris, FranceUniv Paris Saclay, Fac Med, F-94276 Le Kremlin Bicetre, France
Savanovi, Milovan
Allali, Sophiane
论文数: 0引用数: 0
h-index: 0
机构:
Univ Paris, Fac Med, F-75006 Paris, FranceUniv Paris Saclay, Fac Med, F-94276 Le Kremlin Bicetre, France
Allali, Sophiane
Jaros, Drazan
论文数: 0引用数: 0
h-index: 0
机构:
Ctr Radiotherapy, Int Med Ctr, Affidea, Banja Luka 78000, Bosnia & Herceg
Univ Banja Luka, Fac Med, Banja Luka 78000, Bosnia & HercegUniv Paris Saclay, Fac Med, F-94276 Le Kremlin Bicetre, France
Jaros, Drazan
Foulquier, Jean-Noel
论文数: 0引用数: 0
h-index: 0
机构:
Sorbonne Univ, Tenon Hosp, AP HP, Dept Radiat Oncol, F-75020 Paris, FranceUniv Paris Saclay, Fac Med, F-94276 Le Kremlin Bicetre, France