Symmetric Biomechanically Guided Prone-to-Supine Breast Image Registration

被引:20
作者
Eiben, Bjoern [1 ]
Vavourakis, Vasileios [1 ]
Hipwell, John H. [1 ]
Kabus, Sven [2 ]
Buelow, Thomas [2 ]
Lorenz, Cristian [2 ]
Mertzanidou, Thomy [1 ]
Reis, Sara [1 ]
Williams, Norman R. [3 ]
Keshtgar, Mohammed [4 ,5 ]
Hawkes, David J. [1 ]
机构
[1] UCL, Dept Med Phys & Biomed Engn, Ctr Med Image Comp, London WC1E 6BT, England
[2] Res Labs Hamburg, Philips GmbH Innovat Technol, D-22335 Hamburg, Germany
[3] UCL, Div Surg, Clin Trials Grp, London WC1E 6BT, England
[4] Royal Free Hosp, Dept Surg, London NW3 2QG, England
[5] UCL, Div Surg, London WC1E 6BT, England
基金
英国工程与自然科学研究理事会;
关键词
Image analysis; Image registration; Breast cancer; Biomechanics; Modelling; Finite difference method; FINITE-ELEMENT MODEL; NONRIGID REGISTRATION; REFERENCE STATE; DEFORMATIONS; SURGERY; FEASIBILITY;
D O I
10.1007/s10439-015-1496-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Prone-to-supine breast image registration has potential application in the fields of surgical and radiotherapy planning, image guided interventions, and multi-modal cancer diagnosis, staging, and therapy response prediction. However, breast image registration of three dimensional images acquired in different patient positions is a challenging problem, due to large deformations induced to the soft breast tissue caused by the change in gravity loading. We present a symmetric, biomechanical simulation based registration framework which aligns the images in a central, virtually unloaded configuration. The breast tissue is modelled as a neo-Hookean material and gravity is considered as the main source of deformation in the original images. In addition to gravity, our framework successively applies image derived forces directly into the unloading simulation in place of a subsequent image registration step. This results in a biomechanically constrained deformation. Using a finite difference scheme avoids an explicit meshing step and enables simulations to be performed directly in the image space. The explicit time integration scheme allows the motion at the interface between chest and breast to be constrained along the chest wall. The feasibility and accuracy of the approach presented here was assessed by measuring the target registration error (TRE) using a numerical phantom with known ground truth deformations, nine clinical prone MRI and supine CT image pairs, one clinical prone-supine CT image pair and four prone-supine MRI image pairs. The registration reduced the mean TRE for the numerical phantom experiment from initially 19.3 to 0.9 mm and the combined mean TRE for all fourteen clinical data sets from 69.7 to 5.6 mm.
引用
收藏
页码:154 / 173
页数:20
相关论文
共 50 条
[31]   Dosimetric comparison of supine versus prone radiotherapy techniques in patients with breast cancer [J].
Yadav, Budhi Singh ;
Dhingra, Dipti ;
Thakur, Niketa ;
Ghoshal, Sushmita ;
Sharma, Reena ;
Singh, Arun Oinam .
JOURNAL OF RADIATION ONCOLOGY, 2020, 9 (3-4) :243-248
[32]   COVERAGE OF AXILLARY LYMPH NODES IN SUPINE VS. PRONE BREAST RADIOTHERAPY [J].
Alonso-Basanta, Michelle ;
Ko, Jane ;
Babcock, Melissa ;
Dewyngaert, J. Keith ;
Formenti, Silvia C. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (03) :745-751
[33]   Supervoxels for graph cuts-based deformable image registration using guided image filtering [J].
Szmul, Adam ;
Papiez, Bartlomiej W. ;
Hallack, Andre ;
Grau, Vicente ;
Schnabel, Julia A. .
JOURNAL OF ELECTRONIC IMAGING, 2017, 26 (06)
[34]   Comparison of prone versus supine position for whole breast radiotherapy following breast conservation: A dosimetric study [J].
Gopikrishna, M. S. ;
Babu, Geethu ;
Raghavan, Rajeev Kavalakara ;
Gopalakrishnan, Zhenia ;
Menon, Sharika V. ;
George, Preethi Sara ;
Mathew, Beela Sarah .
JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2024, 20 (06) :1866-1871
[35]   Whole breast and regional nodal irradiation in prone versus supine position in left sided breast cancer [J].
Deseyne, Pieter ;
Speleers, Bruno ;
De Neve, Wilfried ;
Boute, Bert ;
Paelinck, Leen ;
Van Hoof, Tom ;
Van de Velde, Joris ;
Van Greveling, Annick ;
Monten, Chris ;
Post, Giselle ;
Depypere, Herman ;
Veldeman, Liv .
RADIATION ONCOLOGY, 2017, 12
[36]   Whole breast and regional nodal irradiation in prone versus supine position in left sided breast cancer [J].
Pieter Deseyne ;
Bruno Speleers ;
Wilfried De Neve ;
Bert Boute ;
Leen Paelinck ;
Tom Van Hoof ;
Joris Van de Velde ;
Annick Van Greveling ;
Chris Monten ;
Giselle Post ;
Herman Depypere ;
Liv Veldeman .
Radiation Oncology, 12
[37]   Feasibility, Image Quality and Clinical Evaluation of Contrast-Enhanced Breast MRI Performed in a Supine Position Compared to the Standard Prone Position [J].
Fausto, Alfonso ;
Fanizzi, Annarita ;
Volterrani, Luca ;
Mazzei, Francesco Giuseppe ;
Calabrese, Claudio ;
Casella, Donato ;
Marcasciano, Marco ;
Massafra, Raffaella ;
La Forgia, Daniele ;
Mazzei, Maria Antonietta .
CANCERS, 2020, 12 (09) :1-13
[38]   Improving oncoplastic breast tumor bed localization for radiotherapy planning using image registration algorithms [J].
Wodzinski, Marek ;
Skalski, Andrzej ;
Ciepiela, Izabela ;
Kuszewski, Tomasz ;
Kedzierawski, Piotr ;
Gajda, Janusz .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03)
[39]   CGNet: A Correlation-Guided Registration Network for Unsupervised Deformable Image Registration [J].
Chang, Yuan ;
Li, Zheng ;
Xu, Wenzheng .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2025, 44 (03) :1468-1479
[40]   A Verification Method of Image Registration for Image-guided Therapy (IGT) [J].
Lung, Young-gi ;
Kim, Myeongjin ;
Nguyen, Thinh T. ;
Lee, Doo Yong .
2014 14TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS 2014), 2014, :294-298