Symmetric Biomechanically Guided Prone-to-Supine Breast Image Registration

被引:20
作者
Eiben, Bjoern [1 ]
Vavourakis, Vasileios [1 ]
Hipwell, John H. [1 ]
Kabus, Sven [2 ]
Buelow, Thomas [2 ]
Lorenz, Cristian [2 ]
Mertzanidou, Thomy [1 ]
Reis, Sara [1 ]
Williams, Norman R. [3 ]
Keshtgar, Mohammed [4 ,5 ]
Hawkes, David J. [1 ]
机构
[1] UCL, Dept Med Phys & Biomed Engn, Ctr Med Image Comp, London WC1E 6BT, England
[2] Res Labs Hamburg, Philips GmbH Innovat Technol, D-22335 Hamburg, Germany
[3] UCL, Div Surg, Clin Trials Grp, London WC1E 6BT, England
[4] Royal Free Hosp, Dept Surg, London NW3 2QG, England
[5] UCL, Div Surg, London WC1E 6BT, England
基金
英国工程与自然科学研究理事会;
关键词
Image analysis; Image registration; Breast cancer; Biomechanics; Modelling; Finite difference method; FINITE-ELEMENT MODEL; NONRIGID REGISTRATION; REFERENCE STATE; DEFORMATIONS; SURGERY; FEASIBILITY;
D O I
10.1007/s10439-015-1496-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Prone-to-supine breast image registration has potential application in the fields of surgical and radiotherapy planning, image guided interventions, and multi-modal cancer diagnosis, staging, and therapy response prediction. However, breast image registration of three dimensional images acquired in different patient positions is a challenging problem, due to large deformations induced to the soft breast tissue caused by the change in gravity loading. We present a symmetric, biomechanical simulation based registration framework which aligns the images in a central, virtually unloaded configuration. The breast tissue is modelled as a neo-Hookean material and gravity is considered as the main source of deformation in the original images. In addition to gravity, our framework successively applies image derived forces directly into the unloading simulation in place of a subsequent image registration step. This results in a biomechanically constrained deformation. Using a finite difference scheme avoids an explicit meshing step and enables simulations to be performed directly in the image space. The explicit time integration scheme allows the motion at the interface between chest and breast to be constrained along the chest wall. The feasibility and accuracy of the approach presented here was assessed by measuring the target registration error (TRE) using a numerical phantom with known ground truth deformations, nine clinical prone MRI and supine CT image pairs, one clinical prone-supine CT image pair and four prone-supine MRI image pairs. The registration reduced the mean TRE for the numerical phantom experiment from initially 19.3 to 0.9 mm and the combined mean TRE for all fourteen clinical data sets from 69.7 to 5.6 mm.
引用
收藏
页码:154 / 173
页数:20
相关论文
共 50 条
  • [21] Breast image registration for surgery: Insights on material mechanics modeling
    Ringel, Morgan J.
    Richey, Winona L.
    Heiselman, Jon
    Luo, Ma
    Meszoely, Ingrid M.
    Miga, Michael, I
    MEDICAL IMAGING 2022: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2022, 12034
  • [22] Prone versus Supine FDG PET/CT in the Staging of Breast Cancer
    Nassar, Lara
    Kassas, Mutaz
    Abi-Ghanem, Alain S.
    El-Jebai, Malak
    Al-Zakleet, Safaa
    Baassiri, Amro S.
    Naccoul, Rami Abou
    Barakat, Andrew
    Tfayli, Arafat
    Assi, Hazem
    Berjawi, Ghina
    Estrada-Lobato, Enrique
    Giammarile, Francesco
    Vinjamuri, Sobhan
    Haidar, Mohamad
    DIAGNOSTICS, 2023, 13 (03)
  • [23] MIND Demons: Symmetric Diffeomorphic Deformable Registration of MR and CT for Image-Guided Spine Surgery
    Reaungamornrat, Sureerat
    De Silva, Tharindu
    Uneri, Ali
    Vogt, Sebastian
    Kleinszig, Gerhard
    Khanna, Akhil J.
    Wolinsky, Jean-Paul
    Prince, Jerry L.
    Siewerdsen, Jeffrey H.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (11) : 2413 - 2424
  • [24] Symmetric Diffeomorphic Image Registration with Multi-Label Segmentation Masks
    Cai, Chenwei
    Wang, Lvda
    Ying, Shihui
    MATHEMATICS, 2022, 10 (11)
  • [25] VOLUME REGULARIZATION IN EXPLICIT IMAGE REGISTRATION USED FOR BREAST CANCER BED LOCALIZATION
    Wodzinski, Marek
    Skalski, Andrzej
    Ciepiela, Izabela
    Kuszewski, Tomasz
    Kedzierawski, Piotr
    2018 IEEE 15TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2018), 2018, : 173 - 176
  • [26] CT Colonography: External Clinical Validation of an Algorithm for Computer-assisted Prone and Supine Registration
    Boone, Darren J.
    Halligan, Steve
    Roth, Holger R.
    Hampshire, Tom E.
    Helbren, Emma
    Slabaugh, Greg G.
    McQuillan, Justine
    McClelland, Jamie R.
    Hu, Mingxing
    Punwani, Shonit
    Taylor, Stuart A.
    Hawkes, David J.
    RADIOLOGY, 2013, 268 (03) : 752 - 760
  • [27] Biomechanical Model as a Registration Tool for Image-Guided Neurosurgery: Evaluation Against BSpline Registration
    Mostayed, Ahmed
    Garlapati, Revanth Reddy
    Joldes, Grand Roman
    Wittek, Adam
    Roy, Aditi
    Kikinis, Ron
    Warfield, Simon K.
    Miller, Karol
    ANNALS OF BIOMEDICAL ENGINEERING, 2013, 41 (11) : 2409 - 2425
  • [28] Biomechanical Model as a Registration Tool for Image-Guided Neurosurgery: Evaluation Against BSpline Registration
    Ahmed Mostayed
    Revanth Reddy Garlapati
    Grand Roman Joldes
    Adam Wittek
    Aditi Roy
    Ron Kikinis
    Simon K. Warfield
    Karol Miller
    Annals of Biomedical Engineering, 2013, 41 : 2409 - 2425
  • [29] Registration for CT image guided spine surgery
    Jia, Fu-Cang
    Li, Xiu-Wang
    Chen, Si-Ping
    Shenzhen Daxue Xuebao (Ligong Ban)/Journal of Shenzhen University Science and Engineering, 2007, 24 (04): : 406 - 409
  • [30] Dosimetric comparison of supine versus prone radiotherapy techniques in patients with breast cancer
    Yadav, Budhi Singh
    Dhingra, Dipti
    Thakur, Niketa
    Ghoshal, Sushmita
    Sharma, Reena
    Singh, Arun Oinam
    JOURNAL OF RADIATION ONCOLOGY, 2020, 9 (3-4) : 243 - 248