Study of ignition delay time and generalization of auto-ignition for PRFs in a RCEM by means of natural chemiluminescence

被引:13
作者
Desantes, J. M. [1 ]
Garcia-Oliver, J. M. [1 ]
Vera-Tudela, W. [1 ,2 ]
Lopez-Pintor, D. [1 ,2 ]
Schneider, B. [2 ]
Boulouchos, K. [2 ]
机构
[1] Univ Politecn Valencia, CMT Motores Term, Camino de Vera S-N, E-46022 Valencia, Spain
[2] ETH, Lab Aerothermochem & Verbrennungssyst, Sonneggstr 3, CH-8092 Zurich, Switzerland
关键词
RCEM; Ignition delay; OH* chemiluminescence; PRF; N-HEPTANE; COMBUSTION; GAS; ISOOCTANE; EGR;
D O I
10.1016/j.enconman.2015.12.052
中图分类号
O414.1 [热力学];
学科分类号
摘要
An investigation of the effects of contour conditions and fuel properties on ignition delay time under Homogeneous Charge Compression Ignition (HCCI) conditions is presented in this study. A parametric variation of initial temperature, intake pressure, compression ratio, oxygen concentration and equivalence ratio has been carried out for Primary Reference Fuels (PRFs) in a Rapid Compression Expansion Machine (RCEM) while applying the optical technique of natural chemiluminescence along with a photo-multiplier. Additionally, the ignition delay time has been calculated from the pressure rise rate and also corresponding numerical simulations with CHEMKIN have been done. The results show that the ignition delay times from the chemical kinetic mechanisms agree with the trends obtained from the experiments. Moreover, the same mechanism proved to yield consistent results for both fuels at a wide range of conditions. On the other hand, the results from natural chemiluminescence also showed agreement with the ignition delay from the pressure signals. A 310 nm interference filter was used in order to detect the chemiluminescence of the OH* radical. In fact, the maximum area and peak intensity of the chemiluminescence measured during the combustion showed that the process of auto-ignition is generalized in the whole chamber. Moreover, the correlation of peak intensity, maximum area and ignition delay time demonstrated that natural chemiluminescence can also be used to calculate ignition delay times under different operating conditions. Finally, the area of chemiluminescence was proved to be more dependant on the fuel and ignition delay time than on the operating conditions. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:217 / 228
页数:12
相关论文
共 27 条
[1]  
[Anonymous], 1999013680 SAE
[2]  
[Anonymous], 1974, The Spectroscopy of Flames
[3]   Exhaust gas recirculation - Zero dimensional modelling and characterization for transient diesel combustion control [J].
Asad, Usman ;
Tjong, Jimi ;
Zheng, Ming .
ENERGY CONVERSION AND MANAGEMENT, 2014, 86 :309-324
[4]  
Augusta R, 2006, SAE TECHNICAL PAPERS, V3
[5]   A reduced mechanism for predicting the ignition timing of a fuel blend of natural-gas and n-heptane in HCCI engine [J].
Bahlouli, Keyvan ;
Atikol, Ugur ;
Saray, R. Khoshbakhti ;
Mohammadi, Vahid .
ENERGY CONVERSION AND MANAGEMENT, 2014, 79 :85-96
[6]  
Barroso G, 2005, 200524038 SAE
[7]   A new methodology for uncertainties characterization in combustion diagnosis and thermodynamic modelling [J].
Benajes, Jesus ;
Olmeda, Pablo ;
Martin, Jaime ;
Carreno, Ricardo .
APPLIED THERMAL ENGINEERING, 2014, 71 (01) :389-399
[8]  
Curran HJ, 1998, TWENTY-SEVENTH SYMPOSIUM (INTERNATIONAL) ON COMBUSTION, VOLS 1 AND 2, P379
[9]   A comprehensive modeling study of iso-octane oxidation [J].
Curran, HJ ;
Gaffuri, P ;
Pitz, WJ ;
Westbrook, CK .
COMBUSTION AND FLAME, 2002, 129 (03) :253-280
[10]   A comprehensive modeling study of n-heptane oxidation [J].
Curran, HJ ;
Gaffuri, P ;
Pitz, WJ ;
Westbrook, CK .
COMBUSTION AND FLAME, 1998, 114 (1-2) :149-177