Determination of Bismuth by Dielectric Barrier Discharge Atomic Absorption Spectrometry Coupled with Hydride Generation: Method Optimization and Evaluation of Analytical Performance

被引:70
|
作者
Kratzer, Jan [1 ,2 ]
Bousek, Jaroslav [3 ]
Sturgeon, Ralph E. [2 ]
Mester, Zoltan [2 ]
Dedina, Jiri [1 ]
机构
[1] Inst Analyt Chem ASCR, Vvi, Brno 60200, Czech Republic
[2] Natl Res Council Canada, Ottawa, ON K1A 0R6, Canada
[3] Brno Univ Technol, Fac Elect Engn & Commun, Brno 61600, Czech Republic
关键词
QUARTZ TUBE ATOMIZERS; PLASMA INDUCED VAPORIZATION; FLUORESCENCE SPECTROMETRY; EMISSION-SPECTROMETRY; MULTIPLE MICROFLAME; ATOMIZATION; STIBINE; MERCURY; SE; SB;
D O I
10.1021/ac502093y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Atomization of bismuth hydride in a 17 W planar quartz dielectric barrier discharge (DBD) atomizer was optimized and the performance of this device compared to that of a conventional quartz tube atomizer (QTA) for atomic absorption spectrometry (AAS). Modification of the inner surface of the DBD atomizer using dimethyldichlorsilane (DMDCS) was essential since it improved sensitivity by a factor of 2-4. Argon, at a flow rate of 125 mL min(-1), was the best DBD discharge gas. Free Bi atoms were also observed in the DBD with nitrogen, hydrogen, and helium discharge gases but not in air. The detection limit for Bi (1.1 ng mL(-1)) is worse than with the QTA (0.16 ng mL(-1) Bi). A poorer detection limit compared to a QTA is a consequence of the shorter optical path of the DBD. Moreover, the lower atomization efficiency and/or faster decay of free atoms in the DBD has to be considered. The performance of the DBD as an atomizer reflects both effects, i.e., atomization efficiency and free atom decay, was estimated to be 65% of that of the externally heated quartz tube atomizer. Nevertheless, this hydride generation DBD-AAS approach can be used for the routine determination of Bi, providing repeatability and accuracy comparable to that reached with a QTA, as demonstrated by analysis of NIST SRM 1643e (trace elements in water). The potential of in-atomizer preconcentration in a DBD atomizer is outlined.
引用
收藏
页码:9620 / 9625
页数:6
相关论文
共 50 条
  • [41] Ultratrace Determination of Tin, Germanium, and Selenium by Hydride Generation Coupled with a Novel Solution-Cathode Glow Discharge-Atomic Emission Spectrometry Method
    Huang, Chuchu
    Li, Qing
    Mo, Jiamei
    Wang, Zheng
    ANALYTICAL CHEMISTRY, 2016, 88 (23) : 11559 - 11567
  • [42] Evaluation of Electrochemical Generation of Volatile Zinc Hydride by Heated Quartz Tube Atomizer Atomic Absorption Spectrometry
    Arbab-Zavar, Mohammad-Hossein
    Chamsaz, Mahmoud
    Youssefi, Abbas
    Aliakbari, Mostafa
    ANALYTICAL SCIENCES, 2012, 28 (07) : 717 - 722
  • [44] EVALUATION OF THE ANALYTICAL CAPABILITY OF THERMAL DESORPTION ATOMIC ABSORPTION SPECTROMETRY METHOD USED FOR MERCURY DETERMINATION IN SEAFOOD
    Senila, Marin
    Cadar, Oana
    Drolc, Andreja
    Pintar, Albin
    Senila, Lacrimioara
    Frentiu, Tiberiu
    STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2016, 61 (03): : 321 - 332
  • [45] A novel gas liquid separator for direct sampling analysis of ultratrace arsenic in blood sample by hydride generation in-situ dielectric barrier discharge atomic fluorescence spectrometry
    Liu, Meitong
    Liu, Tengpeng
    Mao, Xuefei
    Liu, Jixin
    Na, Xing
    Ding, Lan
    Qian, Yongzhong
    TALANTA, 2019, 202 : 178 - 185
  • [46] Multivariate optimization on flow-injection electrochemical hydride generation atomic absorption spectrometry of cadmium
    Arbab-Zavar, M. H.
    Chamsaz, M.
    Youssefi, A.
    Aliakbari, M.
    TALANTA, 2012, 97 : 229 - 234
  • [47] Determination of mercury in food by microwave oven digestion-hydride generation atomic absorption spectrometry
    Lu, D
    Li, HT
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 1999, 19 (03) : 394 - 396
  • [48] Determination of selenium using atomically imprinted polymer (AIP) and hydride generation atomic absorption spectrometry
    de Lima, Grazielle Cabral
    do Lago, Ayla Campos
    Chaves, Arley Alves
    Fadini, Pedro Sergio
    Luccas, Pedro Orival
    ANALYTICA CHIMICA ACTA, 2013, 768 : 35 - 40
  • [49] The online coupling of high performance liquid chromatography with atomic fluorescence spectrometry based on dielectric barrier discharge induced chemical vapor generation for the speciation of mercury
    Liu, Zhifu
    Xing, Zhi
    Li, Zhaoyang
    Zhu, Zhenli
    Ke, Yuqiu
    Jin, Lanlan
    Hu, Shenghong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (03) : 678 - 685
  • [50] Ultra-sensitive determination of inorganic arsenic valence by solution cathode glow discharge-atomic emission spectrometry coupled with hydride generation
    Guo, Xiaohong
    Peng, Xiaoxu
    Li, Qing
    Mo, Jiamei
    Du, Yiping
    Wang, Zheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (12) : 2416 - 2422