Determination of Bismuth by Dielectric Barrier Discharge Atomic Absorption Spectrometry Coupled with Hydride Generation: Method Optimization and Evaluation of Analytical Performance

被引:70
|
作者
Kratzer, Jan [1 ,2 ]
Bousek, Jaroslav [3 ]
Sturgeon, Ralph E. [2 ]
Mester, Zoltan [2 ]
Dedina, Jiri [1 ]
机构
[1] Inst Analyt Chem ASCR, Vvi, Brno 60200, Czech Republic
[2] Natl Res Council Canada, Ottawa, ON K1A 0R6, Canada
[3] Brno Univ Technol, Fac Elect Engn & Commun, Brno 61600, Czech Republic
关键词
QUARTZ TUBE ATOMIZERS; PLASMA INDUCED VAPORIZATION; FLUORESCENCE SPECTROMETRY; EMISSION-SPECTROMETRY; MULTIPLE MICROFLAME; ATOMIZATION; STIBINE; MERCURY; SE; SB;
D O I
10.1021/ac502093y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Atomization of bismuth hydride in a 17 W planar quartz dielectric barrier discharge (DBD) atomizer was optimized and the performance of this device compared to that of a conventional quartz tube atomizer (QTA) for atomic absorption spectrometry (AAS). Modification of the inner surface of the DBD atomizer using dimethyldichlorsilane (DMDCS) was essential since it improved sensitivity by a factor of 2-4. Argon, at a flow rate of 125 mL min(-1), was the best DBD discharge gas. Free Bi atoms were also observed in the DBD with nitrogen, hydrogen, and helium discharge gases but not in air. The detection limit for Bi (1.1 ng mL(-1)) is worse than with the QTA (0.16 ng mL(-1) Bi). A poorer detection limit compared to a QTA is a consequence of the shorter optical path of the DBD. Moreover, the lower atomization efficiency and/or faster decay of free atoms in the DBD has to be considered. The performance of the DBD as an atomizer reflects both effects, i.e., atomization efficiency and free atom decay, was estimated to be 65% of that of the externally heated quartz tube atomizer. Nevertheless, this hydride generation DBD-AAS approach can be used for the routine determination of Bi, providing repeatability and accuracy comparable to that reached with a QTA, as demonstrated by analysis of NIST SRM 1643e (trace elements in water). The potential of in-atomizer preconcentration in a DBD atomizer is outlined.
引用
收藏
页码:9620 / 9625
页数:6
相关论文
共 50 条
  • [31] Ultratrace determination of lead by hydride generation in-atomizer trapping atomic absorption spectrometry: Optimization of plumbane generation and analyte preconcentration in a quartz trap-and-atomizer device
    Kratzer, Jan
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 71-72 : 40 - 47
  • [32] Determination of Tellurium by Atomic Fluorescence Spectrometry Based on Dielectric Barrier Discharge Atomizer
    Kuermaiti, Biekesailike
    Wang Juan
    Han Guo-Jun
    Xing Zhi
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (03) : 357 - 361
  • [33] Plasma-mediated vapor generation of mercury species in a dielectric barrier discharge: Direct analysis in a single drop by atomic absorption spectrometry
    Coelho Jr, Gilberto da S.
    Borges, Daniel L. G.
    Svoboda, Milan
    Dedina, Jiri
    Kratzer, Jan
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2023, 200
  • [34] Critical evaluation of analytical performance of atomic absorption spectrometry and inductively coupled plasma mass spectrometry for mercury detennination
    Krata, A
    Bulska, E
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (03) : 345 - 350
  • [35] Determination of total arsenic in coal and wood using oxygen flask combustion method followed by hydride generation atomic absorption spectrometry
    Geng, Wenhua
    Furuzono, Takuya
    Nakajima, Tsunenori
    Takanashi, Hirokazu
    Ohki, Akira
    JOURNAL OF HAZARDOUS MATERIALS, 2010, 176 (1-3) : 356 - 360
  • [36] Non-aqueous phase hydride generation and determination of trace bismuth by atomic fluorescence spectrometry
    Chen, Luqiong
    Lei, Zirong
    Hu, Kan
    Yang, Shengchun
    Wen, Xiaodong
    MICROCHEMICAL JOURNAL, 2018, 137 : 329 - 333
  • [37] OPTIMIZATION OF CONTINUOUS FLOW HYDRIDE GENERATION INDUCTIVELY COUPLED PLASMA OPTICAL EMISSION SPECTROMETRY FOR SENSITIVITY IMPROVEMENT OF BISMUTH
    Kilinc, Ersin
    Aydin, Firat
    ANALYTICAL LETTERS, 2012, 45 (17) : 2623 - 2636
  • [38] In Situ Dielectric Barrier Discharge Trap for Ultrasensitive Arsenic Determination by Atomic Fluorescence Spectrometry
    Qi, Yuehan
    Mao, Xuefei
    Liu, Jixin
    Na, Xing
    Chen, Guoying
    Liu, Meitong
    Zheng, Chuangmu
    Qian, Yongzhong
    ANALYTICAL CHEMISTRY, 2018, 90 (10) : 6332 - 6338
  • [39] Elemental Determination of Microsamples by Liquid Film Dielectric Barrier Discharge Atomic Emission Spectrometry
    He, Qian
    Zhu, Zhenli
    Hu, Shenghong
    Zheng, Hongtao
    Jin, Lanlan
    ANALYTICAL CHEMISTRY, 2012, 84 (09) : 4179 - 4184
  • [40] Non-chromatographic determination of inorganic and total mercury by atomic absorption spectrometry based on a dielectric barrier discharge atomizer
    Zhu, Zhenli
    Liu, Zhifu
    Zheng, Hongtao
    Hu, Shenghong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (05) : 697 - 703