Effects of Prosthetic Material and Framework Design on Stress Distribution in Dental Implants and Peripheral Bone: A Three-Dimensional Finite Element Analysis

被引:15
作者
Arinc, Hakan [1 ]
机构
[1] Near East Univ, Dept Prosthodont, Fac Dent, Mersin, Turkey
来源
MEDICAL SCIENCE MONITOR | 2018年 / 24卷
关键词
Chromium Alloys; Dental Implants; Finite Element Analysis; Resins; Synthetic; Zirconium; FIXED-PARTIAL DENTURES; CONNECTOR DESIGN; NUMBER; SURVIVAL; FAILURE; COMPLICATIONS; BIOMECHANICS; DIMENSION; STRENGTH;
D O I
10.12659/MSM.908208
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: The purpose of this study was to evaluate the effects of prosthetic material and framework design on the stress within dental implants and peripheral bone using finite element analysis (FEA). Material/Methods: A mandibular implant-supported fixed dental prosthesis with different prosthetic materials [cobalt-chromium-supported ceramic (C), zirconia-supported ceramic (Z), and zirconia-reinforced polymethyl methacrylate (ZRPMMA)-supported resin (ZP)] and different connector widths (2, 3, and 4 mm) within the framework were used to evaluate stress via FEA under oblique loading conditions. Maximum principal (sigma max), minimum principal (sigma min), and von Mises (sigma vM) stress values were obtained. Results: Minimum stress values were observed in the model with a 2-mm connector width for C and ZP. The models with 3-mm and 4-mm connector widths showed higher stress values than the model with a 2-mm connector width for C (48-50%) and ZP (50-52%). Similar stress values were observed in the 3-and 4-mm models. There was no significant difference in the amount of stress with Z regardless of connector width. The Z and ZP models showed similar stress values in the 3-and 4-mm models and higher stress values than in the C model. Z, ZP, and C showed the highest stress values for the model with a 2-mm connector width. Conclusions: Changes in the material and width of connectors may influence stress on cortical bone, cancellous bone, and implants. C was associated with the lowest stress values. Higher maximum and minimum principal stress values were seen in cortical bone compared to cancellous bone.
引用
收藏
页码:4279 / 4287
页数:9
相关论文
共 50 条
  • [21] Three-Dimensional Finite Element Analysis of Stress Distribution on Different Bony Ridges With Different Lengths of Morse Taper Implants and Prosthesis Dimensions
    Toniollo, Marcelo Bighetti
    Macedo, Ana Paula
    Silveira Rodrigues, Renata Cristina
    Ribeiro, Ricardo Faria
    Chiarello de Mattos, Maria da Gloria
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2012, 23 (06) : 1888 - 1892
  • [22] Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis
    Tada, S
    Stegaroiu, R
    Kitamura, E
    Miyakawa, O
    Kusakari, H
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (03) : 357 - 368
  • [23] Stress Distribution in Single Dental Implant System: Three-Dimensional Finite Element Analysis Based on an In Vitro Experimental Model
    Edwards Rezende, Carlos Eduardo
    Chase-Diaz, Melody
    Costa, Max Doria
    Albarracin, Max Laurent
    Paschoeto, Gabriela
    Capello Sousa, Edson Antonio
    Rubo, Jose Henrique
    Sanches Borges, Ana Flavia
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (07) : 2196 - 2200
  • [24] Evaluation of Stresses Occurring on Three Different Zirconia Dental Implants: Three-Dimensional Finite Element Analysis
    Caglar, Alper
    Bal, Bilge Turhan
    Aydin, Cemal
    Yilmaz, Handan
    Ozkan, Secil
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (01) : 95 - 103
  • [25] Three-Dimensional Finite Element Analysis on Stress Distribution of Internal Implant-Abutment Engagement Features
    Cho, Sung-Yong
    Huh, Yun-Hyuk
    Park, Chan-Jin
    Cho, Lee-Ra
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (02) : 319 - 327
  • [26] Effect of different restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone: A three-dimensional finite element analysis study
    Kaleli, Necati
    Sarac, Duygu
    Kulunk, Safak
    Ozturk, Ozgur
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (03) : 437 - 445
  • [27] Biomechanical Analysis of Different Framework Design, Framework Material and Bone Density in the Edentulous Mandible With Fixed Implant-Supported Prostheses: A Three-Dimensional Finite Element Study
    Yu, Wenqian
    Chen, Siyi
    Ma, Li
    Ma, Xiaoni
    Xu, Xin
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (04): : 309 - 317
  • [28] Three-dimensional finite element analysis of extra short implants focusing on implant designs and materials
    Araki, Haruka
    Nakano, Tamaki
    Ono, Shinji
    Yatani, Hirofumi
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [29] Three-Dimensional Finite Element Analysis of the Effect of Endosteal Implants with Different Macro Designs on Stress Distribution in Different Bone Qualities
    Yalcin, Mustafa
    Kaya, Beyza
    Lacin, Nihat
    Ari, Emre
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (03) : E43 - E50
  • [30] Three-dimensional finite element analysis of stress distribution in retention screws of different crown-implant ratios
    Moraes, S. L. D.
    Pellizzer, E. P.
    Verri, F. R.
    Santiago, J. F., Jr.
    Silva, J. V. L.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 (07) : 689 - 696