Effects of Prosthetic Material and Framework Design on Stress Distribution in Dental Implants and Peripheral Bone: A Three-Dimensional Finite Element Analysis

被引:17
作者
Arinc, Hakan [1 ]
机构
[1] Near East Univ, Dept Prosthodont, Fac Dent, Mersin, Turkey
来源
MEDICAL SCIENCE MONITOR | 2018年 / 24卷
关键词
Chromium Alloys; Dental Implants; Finite Element Analysis; Resins; Synthetic; Zirconium; FIXED-PARTIAL DENTURES; CONNECTOR DESIGN; NUMBER; SURVIVAL; FAILURE; COMPLICATIONS; BIOMECHANICS; DIMENSION; STRENGTH;
D O I
10.12659/MSM.908208
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: The purpose of this study was to evaluate the effects of prosthetic material and framework design on the stress within dental implants and peripheral bone using finite element analysis (FEA). Material/Methods: A mandibular implant-supported fixed dental prosthesis with different prosthetic materials [cobalt-chromium-supported ceramic (C), zirconia-supported ceramic (Z), and zirconia-reinforced polymethyl methacrylate (ZRPMMA)-supported resin (ZP)] and different connector widths (2, 3, and 4 mm) within the framework were used to evaluate stress via FEA under oblique loading conditions. Maximum principal (sigma max), minimum principal (sigma min), and von Mises (sigma vM) stress values were obtained. Results: Minimum stress values were observed in the model with a 2-mm connector width for C and ZP. The models with 3-mm and 4-mm connector widths showed higher stress values than the model with a 2-mm connector width for C (48-50%) and ZP (50-52%). Similar stress values were observed in the 3-and 4-mm models. There was no significant difference in the amount of stress with Z regardless of connector width. The Z and ZP models showed similar stress values in the 3-and 4-mm models and higher stress values than in the C model. Z, ZP, and C showed the highest stress values for the model with a 2-mm connector width. Conclusions: Changes in the material and width of connectors may influence stress on cortical bone, cancellous bone, and implants. C was associated with the lowest stress values. Higher maximum and minimum principal stress values were seen in cortical bone compared to cancellous bone.
引用
收藏
页码:4279 / 4287
页数:9
相关论文
共 36 条
[1]  
Akay C, 2015, MED SCI MONITOR, V21, P604, DOI 10.12659/MSM.892680
[2]   Stress distribution in fixed-partial prosthesis and peri-implant bone tissue with different framework materials and vertical misfit levels: a three-dimensional finite element analysis [J].
Bacchi, Atais ;
Consani, Rafael L. X. ;
Mesquita, Marcelo F. ;
dos Santos, Mateus B. F. .
JOURNAL OF ORAL SCIENCE, 2013, 55 (03) :239-244
[3]  
Bahat Z, 2009, SWED DENT J, V33, P149
[4]   Effect of ceramic infrastructure on the failure behavior and stress distribution of fixed partial dentures [J].
Borba, Marcia ;
Duan, Yuanyuan ;
Griggs, Jason A. ;
Cesar, Paulo F. ;
Della Bona, Alvaro .
DENTAL MATERIALS, 2015, 31 (04) :413-422
[5]  
Brunski JB, 2000, INT J ORAL MAX IMPL, V15, P15
[6]   Risk factors for dental implant failure: A strategy for the analysis of clustered failure-time observations [J].
Chuang, SK ;
Wei, LJ ;
Douglass, CW ;
Dodson, TB .
JOURNAL OF DENTAL RESEARCH, 2002, 81 (08) :572-577
[7]  
Deger Y, 2015, MED SCI MONITOR, V21, P3716
[8]   The role of superstructure material on the stress distribution in mandibular full-arch implant-supported fixed dentures. A CT-based 3D-FEA [J].
Ferreira, Mayara Barbosa ;
Bardo, Valentim Adelino ;
Faverani, Leonardo Perez ;
Hipolito, Ana Carolina ;
Assuncao, Wirley Goncalves .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 35 :92-99
[9]  
Gomes ÉA, 2011, INT J ORAL MAX IMPL, V26, P1202
[10]   Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone [J].
Iplikçioglu, H ;
Akça, K .
JOURNAL OF DENTISTRY, 2002, 30 (01) :41-46