Effects of Prosthetic Material and Framework Design on Stress Distribution in Dental Implants and Peripheral Bone: A Three-Dimensional Finite Element Analysis

被引:15
|
作者
Arinc, Hakan [1 ]
机构
[1] Near East Univ, Dept Prosthodont, Fac Dent, Mersin, Turkey
来源
MEDICAL SCIENCE MONITOR | 2018年 / 24卷
关键词
Chromium Alloys; Dental Implants; Finite Element Analysis; Resins; Synthetic; Zirconium; FIXED-PARTIAL DENTURES; CONNECTOR DESIGN; NUMBER; SURVIVAL; FAILURE; COMPLICATIONS; BIOMECHANICS; DIMENSION; STRENGTH;
D O I
10.12659/MSM.908208
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: The purpose of this study was to evaluate the effects of prosthetic material and framework design on the stress within dental implants and peripheral bone using finite element analysis (FEA). Material/Methods: A mandibular implant-supported fixed dental prosthesis with different prosthetic materials [cobalt-chromium-supported ceramic (C), zirconia-supported ceramic (Z), and zirconia-reinforced polymethyl methacrylate (ZRPMMA)-supported resin (ZP)] and different connector widths (2, 3, and 4 mm) within the framework were used to evaluate stress via FEA under oblique loading conditions. Maximum principal (sigma max), minimum principal (sigma min), and von Mises (sigma vM) stress values were obtained. Results: Minimum stress values were observed in the model with a 2-mm connector width for C and ZP. The models with 3-mm and 4-mm connector widths showed higher stress values than the model with a 2-mm connector width for C (48-50%) and ZP (50-52%). Similar stress values were observed in the 3-and 4-mm models. There was no significant difference in the amount of stress with Z regardless of connector width. The Z and ZP models showed similar stress values in the 3-and 4-mm models and higher stress values than in the C model. Z, ZP, and C showed the highest stress values for the model with a 2-mm connector width. Conclusions: Changes in the material and width of connectors may influence stress on cortical bone, cancellous bone, and implants. C was associated with the lowest stress values. Higher maximum and minimum principal stress values were seen in cortical bone compared to cancellous bone.
引用
收藏
页码:4279 / 4287
页数:9
相关论文
共 50 条
  • [1] A three-dimensional finite element analysis of the stress distribution on morse taper implants surface
    Toniollo, Marcelo Bighetti
    Macedo, Ana Paula
    Silveira Rodrigues, Renata Cristina
    Ribeiro, Ricardo Faria
    Chiarello de Mattos, Maria da Gloria
    JOURNAL OF PROSTHODONTIC RESEARCH, 2013, 57 (03) : 206 - 212
  • [2] Effect of microthread design of dental implants on stress and strain patterns: a three-dimensional finite element analysis
    Amid, Reza
    Raoofi, Saeed
    Kadkhodazadeh, Mahdi
    Movahhedi, Mohammad Reza
    Khademi, Maryam
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58 (05): : 457 - 467
  • [3] Three-Dimensional Finite Element Analysis of Stress Distribution in Zirconia and Titanium Dental Implants
    Villabona Lopez, Camilo Andres
    Amorin Vasco, Marco Antonio
    Ruales, Edwin
    Bedoya, Karin Apaza
    Benfatti, Cesar Magalhaes
    Luis Bezzon, Osvaldo
    Deliberador, Tatiana Miranda
    JOURNAL OF ORAL IMPLANTOLOGY, 2018, 44 (06) : 409 - 415
  • [4] The influence of framework material on stress distribution in maxillary complete-arch fixed prostheses supported by four dental implants: a three-dimensional finite element analysis
    Dayan, Suleyman Cagatay
    Geckili, Onur
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (14) : 1606 - 1617
  • [5] Three-Dimensional Finite Element Analysis of Stress Distribution in Dental Implant Prosthesis and Surrounding Bone Using PEEK Abutments
    Hong, Min-Ho
    Choi, Hyunsuk
    BIOMIMETICS, 2024, 9 (08)
  • [6] Effect of Offset Implant Placement on the Stress Distribution Around a Dental Implant: A Three-Dimensional Finite Element Analysis
    Siadat, Hakimeh
    Hashemzadeh, Shervin
    Geramy, Allahyar
    Bassir, Seyed Hossein
    Alikhasi, Marzieh
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (06) : 646 - 651
  • [7] Influence of different implant-abutment connections on stress distribution in single tilted implants and peripheral bone: A three-dimensional finite element analysis
    Ozturk, Ozgur
    Kulunk, Tolga
    Kulunk, Safak
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2018, 29 (04) : 513 - 526
  • [8] Three-Dimensional Finite Element Analysis of Prosthetic Finger Joint Implants
    E.A. Biddis
    E.R. Bogoch
    S.A. Meguid
    International Journal of Mechanics and Materials in Design, 2004, 1 (4) : 317 - 328
  • [9] Influence of restoration type on stress distribution in bone around implants: A three-dimensional finite element analysis
    Stegaroiu, R
    Sato, T
    Kusakari, H
    Miyakawa, O
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1998, 13 (01) : 82 - 90
  • [10] Influence of Implant Collar Design on Stress and Strain Distribution in the Crestal Compact Bone: A Three-Dimensional Finite Element Analysis
    Shen, Wan-Ling
    Chen, Chen-Sheng
    Hsu, Ming-Lun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (05) : 901 - 910