Assessment of five different probes for lung ultrasound in critically ill patients: A pilot study

被引:23
|
作者
Bobbia, Xavier [1 ,2 ]
Chabannon, Margaux [1 ]
Chevallier, Thierry [3 ]
de La Coussaye, Jean Emmanuel [1 ]
Lefrant, Jean Yves [1 ]
Pujol, Sarah [1 ]
Claret, Pierre-Geraud [1 ]
Zieleskiewicz, Laurent [4 ]
Roger, Claire [1 ]
Muller, Laurent [1 ]
机构
[1] Nimes Univ Hosp, Intens Care Unit, Dept Anesthesiol Emergency & Crit Care Med, Pl Pr Debre, F-30029 Nimes, France
[2] Aix Marseille Univ, Timone Hosp 2, Emergency Dept, Marseille, France
[3] Univ Hosp Nimes, Biostat Epidemiol Publ Hlth & Med Informat, Pl Prof Robert Debre, F-30029 Nimes, France
[4] Univ Hosp Marseille, Dept Anesthesia & Intens Care, Chemin Bourrely, F-13915 Marseille 20, France
关键词
Critical care; Emergency medicine; Lung; Ultrasonography; COMET-TAIL ARTIFACT; ACUTE RESPIRATORY-FAILURE; SIGN; PNEUMOTHORAX; AGREEMENT; PROTOCOL;
D O I
10.1016/j.ajem.2018.03.077
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: The present study was aimed at comparing the diagnosis concordance of five echo probes of lung ultrasound (LUS) with CT scans in intensive care and emergency patients with acute respiratory failure. Materials: This prospective, observational, pilot study involved 10 acute patients in whom a thoracic CT scan was performed. An expert performed an LUS reference exam using five different probes: three probes with a high-quality conventional echo machine (cardiac phased-array probe, abdominal convex probe, linear probe) and two probes (cardiac and linear) with a pocket ultrasound device (PUD). Then, a trained physician and a resident performed 'blinded' analyses by viewing the video results on a computer. The primary objective was to test concordance between the blinded echo diagnosis and the CT scan. Results: In the 100 LUS performed, the phased-array probe of the conventional machine and linear array probe of the PUD have the best concordance with the CT scan (Kappa coefficient=0.75 [CI 95%=0.54-0.96] and 0.62 [CI 95%=0.37-0.86], respectively) only for experts and trained physicians. The agreement was always poor for residents. Convex (abdominal) and linear transducers of conventional machines and the phased-array transducers (cardiac) of PUD have poor or very poor agreement, regardless of the physician's experience. Conclusion: Among the probes tested for LUS in acute patients, the cardiac probe of conventional machines and the linear probes of PUDs provide good diagnosis concordance with CT scans when performed by an expert and trained physician, but not by residents. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:1265 / 1269
页数:5
相关论文
共 50 条
  • [31] Mechanical Ventilation and Diaphragmatic Atrophy in Critically Ill Patients: An Ultrasound Study
    Zambon, Massimo
    Beccaria, Paolo
    Matsuno, Jun
    Gemma, Marco
    Frati, Elena
    Colombo, Sergio
    Cabrini, Luca
    Landoni, Giovanni
    Zangrillo, Alberto
    CRITICAL CARE MEDICINE, 2016, 44 (07) : 1347 - 1352
  • [32] Hospital survey of point-of-care lung ultrasound use in the assessment of peri-operative and critically ill patients
    Kelvin Lam
    David Canty
    Colin Royse
    Alistair Royse
    Critical Care, 16
  • [33] A BEDSIDE ULTRASOUND SIGN RULING OUT PNEUMOTHORAX IN THE CRITICALLY ILL - LUNG SLIDING
    LICHTENSTEIN, DA
    MENU, Y
    CHEST, 1995, 108 (05) : 1345 - 1348
  • [34] Ultrasound in critically ill patients: focus on diaphragm
    Zambon, Massimo
    Cabrini, Luca
    Beccaria, Paolo
    Zangrillo, Alberto
    Colombo, Sergio
    INTENSIVE CARE MEDICINE, 2013, 39 (05) : 986 - 986
  • [35] Physical capacities assessment in critically ill patients: An exploratory study
    Rousseau, Anne-Francoise
    Kellens, Isabelle
    Dardenne, Nadia
    Misset, Benoit
    Croisier, Jean-Louis
    AUSTRALIAN CRITICAL CARE, 2022, 35 (06) : 709 - 713
  • [36] Point of care echocardiography and lung ultrasound in critically ill patients with COVID-19
    Altersberger, Martin
    Schneider, Matthias
    Schiller, Martina
    Binder-Rodriguez, Christina
    Genger, Martin
    Khafaga, Mounir
    Binder, Thomas
    Prosch, Helmut
    WIENER KLINISCHE WOCHENSCHRIFT, 2021, 133 (23-24) : 1298 - 1309
  • [37] Hospital survey of point-of-care lung ultrasound use in the assessment of peri-operative and critically ill patients
    Lam, Kelvin
    Canty, David
    Royse, Colin
    Royse, Alistair
    CRITICAL CARE, 2012, 16 (03):
  • [38] Point-of-care assessment of microvascular blood flow in critically ill patients
    Arnold, Ryan C.
    Parrillo, Joseph E.
    Dellinger, R. Phillip
    Chansky, Michael E.
    Shapiro, Nathan I.
    Lundy, David J.
    Trzeciak, Stephen
    Hollenberg, Steven M.
    INTENSIVE CARE MEDICINE, 2009, 35 (10) : 1761 - 1766
  • [39] Diaphragm ultrasound as indicator of respiratory effort in critically ill patients undergoing assisted mechanical ventilation: a pilot clinical study
    Umbrello, Michele
    Formenti, Paolo
    Longhi, Daniela
    Galimberti, Andrea
    Piva, Ilaria
    Pezzi, Angelo
    Mistraletti, Giovanni
    Marini, John J.
    Iapichino, Gaetano
    CRITICAL CARE, 2015, 19
  • [40] Peripheral muscular ultrasound as outcome assessment tool in critically ill patients on mechanical ventilation: An observational cohort study
    Toledo, Diogo Oliveira
    de Freitas, Branca Jardini
    Dib, Rogerio
    do Amaral Pfeilsticker, Flavia Julie
    dos Santos, Dyaiane Marques
    Gomes, Brenno Cardoso
    Silva-Jr, Joao Manoel
    CLINICAL NUTRITION ESPEN, 2021, 43 : 408 - 414