Assessment of five different probes for lung ultrasound in critically ill patients: A pilot study

被引:23
|
作者
Bobbia, Xavier [1 ,2 ]
Chabannon, Margaux [1 ]
Chevallier, Thierry [3 ]
de La Coussaye, Jean Emmanuel [1 ]
Lefrant, Jean Yves [1 ]
Pujol, Sarah [1 ]
Claret, Pierre-Geraud [1 ]
Zieleskiewicz, Laurent [4 ]
Roger, Claire [1 ]
Muller, Laurent [1 ]
机构
[1] Nimes Univ Hosp, Intens Care Unit, Dept Anesthesiol Emergency & Crit Care Med, Pl Pr Debre, F-30029 Nimes, France
[2] Aix Marseille Univ, Timone Hosp 2, Emergency Dept, Marseille, France
[3] Univ Hosp Nimes, Biostat Epidemiol Publ Hlth & Med Informat, Pl Prof Robert Debre, F-30029 Nimes, France
[4] Univ Hosp Marseille, Dept Anesthesia & Intens Care, Chemin Bourrely, F-13915 Marseille 20, France
关键词
Critical care; Emergency medicine; Lung; Ultrasonography; COMET-TAIL ARTIFACT; ACUTE RESPIRATORY-FAILURE; SIGN; PNEUMOTHORAX; AGREEMENT; PROTOCOL;
D O I
10.1016/j.ajem.2018.03.077
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: The present study was aimed at comparing the diagnosis concordance of five echo probes of lung ultrasound (LUS) with CT scans in intensive care and emergency patients with acute respiratory failure. Materials: This prospective, observational, pilot study involved 10 acute patients in whom a thoracic CT scan was performed. An expert performed an LUS reference exam using five different probes: three probes with a high-quality conventional echo machine (cardiac phased-array probe, abdominal convex probe, linear probe) and two probes (cardiac and linear) with a pocket ultrasound device (PUD). Then, a trained physician and a resident performed 'blinded' analyses by viewing the video results on a computer. The primary objective was to test concordance between the blinded echo diagnosis and the CT scan. Results: In the 100 LUS performed, the phased-array probe of the conventional machine and linear array probe of the PUD have the best concordance with the CT scan (Kappa coefficient=0.75 [CI 95%=0.54-0.96] and 0.62 [CI 95%=0.37-0.86], respectively) only for experts and trained physicians. The agreement was always poor for residents. Convex (abdominal) and linear transducers of conventional machines and the phased-array transducers (cardiac) of PUD have poor or very poor agreement, regardless of the physician's experience. Conclusion: Among the probes tested for LUS in acute patients, the cardiac probe of conventional machines and the linear probes of PUDs provide good diagnosis concordance with CT scans when performed by an expert and trained physician, but not by residents. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:1265 / 1269
页数:5
相关论文
共 50 条
  • [1] Lung ultrasound in the critically ill
    Lichtenstein, D. A.
    NETHERLANDS JOURNAL OF CRITICAL CARE, 2012, 16 (02): : 43 - 51
  • [2] Lung ultrasound in critically ill patients: a new diagnostic tool
    Dexheimer Neto, Felippe Leopoldo
    Roth Dalcin, Paulo de Tarso
    Teixeira, Cassiano
    Beltrami, Flavia Gabe
    JORNAL BRASILEIRO DE PNEUMOLOGIA, 2012, 38 (02) : 246 - 256
  • [3] Lung Ultrasound for Critically Ill Patients
    Mojoli, Francesco
    Bouhemad, Belaid
    Mongodi, Silvia
    Lichtenstein, Daniel
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199 (06) : 701 - 714
  • [4] Lung ultrasound in the critically ill
    Lichtenstein, Daniel A.
    ANNALS OF INTENSIVE CARE, 2014, 4 : 1 - 12
  • [5] Lung ultrasound in the critically ill
    Daniel A Lichtenstein
    Annals of Intensive Care, 4
  • [6] Lung Ultrasound as a Bedside Tool for Assessment of Extravascular Lung Water in Critically Ill Head Injured Patients: An Observational Study
    Gattupalli, Vasavi
    Jain, Kajal
    Samra, Tanvir
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2019, 23 (03) : 131 - 134
  • [7] Better With Ultrasound Pleural Procedures in Critically Ill Patients
    Millington, Scott J.
    Koenig, Seth
    CHEST, 2018, 153 (01) : 224 - 232
  • [8] Extended Lung Ultrasound to Differentiate Between Pneumonia and Atelectasis in Critically Ill Patients: A Diagnostic Accuracy Study
    Haaksma, Mark E.
    Smit, Jasper M.
    Heldeweg, Micah L. A.
    Nooitgedacht, Jip S.
    de Grooth, Harm J.
    Jonkman, Annemijn H.
    Girbes, Armand R. J.
    Heunks, Leo
    Tuinman, Pieter R.
    CRITICAL CARE MEDICINE, 2022, 50 (05) : 750 - 759
  • [9] Lung ultrasound in the critically ill
    Lichtenstein, Daniel
    CURRENT OPINION IN CRITICAL CARE, 2014, 20 (03) : 315 - 322
  • [10] Impact of lung ultrasound on clinical decision making in critically ill patients
    Xirouchaki, Nektaria
    Kondili, Eumorfia
    Prinianakis, George
    Malliotakis, Polychronis
    Georgopoulos, Dimitrios
    INTENSIVE CARE MEDICINE, 2014, 40 (01) : 57 - 65