摘要
A novel organic polymer monolithic column with reversed-phase/hydrophilic (RPLC/HILIC) bifunctional interaction mixed-mode was successfully synthesized with the monomers 4-vinylbiphenyl and vinylbenzyl trimethylammonium chloride and the cross-linker ethylene dimethacrylate by in situ copolymerization in a binary porogenic solvent consisting of cyclohexanol and dodecanol for capillary electrochromatography. The stationary phases formed by styrene-based monomers can allow powerful pi-pi, hydrophobic and hydrophilic interactions, which is beneficial for the chromatographic separation with high resolution and high column efficiency. One mixed-mode monolithic column can work as two individual mode columns based on the combination of binary RPLC and HILIC separation mechanisms. Vanillin substances and neutral and alkaline compounds can be separated perfectly on the monolithic column in different chromatographic modes which can be switched by changing the content of the organic modifier in the running phase. For benzene, the highest column efficiency was 3.49 x 10(5) plates per m (theoretical plates, N). The relative standard deviations of retention time of different test analytes for intra-day (n = 5), inter-day (n = 5), column-to-column (n = 3) and batch-to-batch (n = 3) reproducibility were all less than 5.0%. All these results demonstrate that the monolithic column with RPLC/HILIC mixed-mode has great application potential.
引用
收藏
页码:4386 / 4394
页数:9
相关论文
共 50 条
  • [1] Preparation of a monolithic column with a mixed-mode stationary phase of reversed-phase/hydrophilic interaction for capillary liquid chromatography
    Zhang, Meng
    Gong, Li
    Liu, Guizhen
    Kang, Jingwu
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (03) : 662 - 669
  • [2] Sulfoalkylbetaine-based monolithic column with mixed-mode of hydrophilic interaction and strong anion-exchange stationary phase for capillary electrochromatography
    Wang, Xiaochun
    Ding, Kang
    Yang, Chunmei
    Lin, Xucong
    Lue, Haixia
    Wu, Xiaoping
    Xie, Zenghong
    ELECTROPHORESIS, 2010, 31 (17) : 2997 - 3005
  • [3] Reversed-phase and weak anion-exchange mixed-mode silica-based monolithic column for capillary electrochromatography
    Ding, Guosheng
    Da, Zhenliang
    Yuan, Ruijuan
    Bao, James J.
    ELECTROPHORESIS, 2006, 27 (17) : 3363 - 3372
  • [4] Fast separation of pyrimidine derivatives by capillary electrochromatography on ion-exchange/reversed-phase mixed-mode stationary phases
    Klampfl, CW
    Buchberger, W
    Haddad, PR
    JOURNAL OF CHROMATOGRAPHY A, 2001, 911 (02) : 277 - 283
  • [5] A benzenesulfonic acid-modified organic polymer monolithic column with reversed-phase/hydrophilic bifunctional selectivity for capillary electrochromatography
    Liu, Yikun
    He, Ning
    Lu, Yingfang
    Li, Weiqiang
    He, Xin
    Li, Zhentao
    Chen, Zilin
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2023, 13 (02) : 209 - 215
  • [6] Separation of peptides on mixed mode of reversed-phase and ion-exchange capillary electrochromatography with a monolithic column
    Wu, RA
    Zou, HF
    Fu, HJ
    Jin, WH
    Ye, ML
    ELECTROPHORESIS, 2002, 23 (09) : 1239 - 1245
  • [7] Quinine-modified polymer monolithic column with reversed-phase /strong anion-exchange mixed-mode for pressurized capillary electrochromatography
    Wang, Jiabin
    Ding, Changying
    Xiao, Jianhua
    Jia, Wenchao
    Chen, Yongxuan
    Lin, Xucong
    Xie, Zenghong
    ELECTROPHORESIS, 2018, 39 (12) : 1504 - 1511
  • [8] An innovative reversed-phase monolithic column modified with 4-vinylbiphenyl and ionic liquid stationary phases for capillary electrochromatography
    Mao, Xiangju
    Liu, Lu
    Xiao, Fang
    Ni, Wenshan
    Cheng, Xintao
    NEW JOURNAL OF CHEMISTRY, 2019, 43 (30) : 12013 - 12019
  • [9] Capillary electrochromatography of charged biomolecules with mixed-mode stationary phases
    Ohyama, Kaname
    Kuroda, Naotaka
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2007, 30 (5-8) : 833 - 851
  • [10] Preparation of Cationic Mixed-Mode Acrylamide-Based Monolithic Stationary Phases for Capillary Electrochromatography
    “Ayat Allah” Al-Massaedh
    Ute Pyell
    Chromatographia, 2018, 81 : 1325 - 1336