An MR-Conditional High-Torque Pneumatic Stepper Motor for MRI-Guided and Robot-Assisted Intervention

被引:43
作者
Chen, Yue [1 ]
Kwok, Ka-Wai [1 ,2 ,3 ]
Tse, Zion Tsz Ho [1 ]
机构
[1] Univ Georgia, Coll Engn, Athens, GA 30602 USA
[2] Harvard Univ, Brigham & Womens Hosp, Sch Med, Boston, MA 02115 USA
[3] Univ Hong Kong, Dept Mech Engn, Hong Kong, Hong Kong, Peoples R China
基金
美国国家卫生研究院;
关键词
MRI; Pneumatic stepper motor; MR-conditional; IN-VIVO; PERFORMANCE; DEVICE; OTTO;
D O I
10.1007/s10439-014-1049-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic resonance imaging allows for visualizing detailed pathological and morphological changes of soft tissue. MR-conditional actuations have been widely investigated for development of image-guided and robot-assisted surgical devices under the Magnetic resonance imaging (MRI). This paper presents a simple design of MR-conditional stepper motor which can provide precise and high-torque actuation without adversely affecting the MR image quality. This stepper motor consists of two MR-conditional pneumatic cylinders and the corresponding supporting structures. Alternating the pressurized air can drive the motor to rotate each step in 3.6A degrees with the motor coupled to a planetary gearbox. Experimental studies were conducted to validate its dynamics performance. Maximum 800 mN m output torque is achieved. The motor accuracy independently varied by two factors: motor operating speed and step size, was also investigated. The motor was tested within a 3T Siemens MRI scanner (MAGNETOM Skyra, Siemens Medical Solutions, Erlangen, Germany) and a 3T GE MRI scanner (GE SignaHDx, GE Healthcare, Milwaukee, WI, USA). The image artifact and the signal-to-noise ratio (SNR) were evaluated for study of its MRI compliancy. The results show that the presented pneumatic stepper motor generated 2.35% SNR reduction in MR images. No observable artifact was presented besides the motor body itself. The proposed motor test also demonstrates a standard to evaluate the pneumatic motor capability for later incorporation with motorized devices used under MRI.
引用
收藏
页码:1823 / 1833
页数:11
相关论文
共 34 条
  • [1] ASTM, 2013, F2119 ASTM
  • [2] Bergeles C, 2013, IEEE INT CONF ROBOT, P698, DOI 10.1109/ICRA.2013.6630649
  • [3] Bhavikatti SS, 1994, ENG MECH
  • [4] A pneumatic vibrotactile stimulation device for fMRI
    Briggs, RW
    Dy-Liacco, I
    Malcolm, MP
    Lee, H
    Peck, KK
    Gopinath, KS
    Himes, NC
    Soltysik, DA
    Browne, P
    Tran-Soy-Tay, R
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (03) : 640 - 643
  • [5] Cai M, 2001, IMECHE CONF TRANS, V2001, P381
  • [6] Power assessment of flowing compressed air
    Cai, ML
    Kawashirna, K
    Kagawa, T
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (02): : 402 - 405
  • [7] Chen Y., 2014, J CARDIOVASC MAGN R, V16, pP150, DOI DOI 10.1186/1532-429X-16-S1-P150
  • [8] Chinzei K, 1999, LECT NOTES COMPUT SC, V1679, P1020
  • [9] MRI-compatible pneumatic robot for transperineal prostate needle placement
    Fischer, Gregory S.
    Iordachita, Iulian
    Csoma, Csaba
    Tokuda, Junichi
    DiMaio, Simon P.
    Tempany, Clare M.
    Hata, Nobuhiko
    Fichtinger, Gabor
    [J]. IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2008, 13 (03) : 295 - 305
  • [10] Actuation methods for applications in MR environments
    Gassert, Roger
    Yamamoto, Akio
    Chapuis, Dominique
    Dovat, Luidovic
    Bleuler, Hannes
    Burdet, Etienne
    [J]. CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2006, 29B (04) : 191 - 209