Methods to evaluate the performance of kilovoltage cone-beam computed tomography in the three-dimensional reconstruction space

被引:2
作者
Zhang, J.
Bao, Z. R.
Huang, X. T.
Jiang, D. Z.
Xie, C. H.
Zhou, Y. F.
Liu, H. [1 ]
机构
[1] Wuhan Univ, Zhongnan Hosp, Dept Radiat & Med Oncol, Wuhan, Hubei, Peoples R China
来源
INTERNATIONAL JOURNAL OF RADIATION RESEARCH | 2019年 / 17卷 / 02期
关键词
Image quality; CBCT; three-dimensional; IMAGE-GUIDED RADIOTHERAPY; QUALITY-ASSURANCE PROGRAM; FLAT-PANEL IMAGER; RADIATION-THERAPY; CT; SYSTEM; KV; LOCALIZATION; PROJECTIONS; ULTRASOUND;
D O I
10.18869/acadpub.ijrr.17.2.189
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Cone-beam computed tomography (CBCT) scanners for image-guided radiotherapy are in clinical use today, but there has been no consensus on uniform acceptance to verify the CBCT image quality yet. The present work proposed new methods to fully evaluate the performance of CBCT in its three-dimensional (3D) reconstruction space. Material and Methods: Compared to the traditional methods with only two-dimensional axial slice evaluated, the new methods were designed to evaluate the CBCT image quality not only in the axial slices but also along three dimensions and three sections. Image parameters were evaluated by scanning the corresponding phantom. Results: The new methods demonstrated the high spatial resolution, the image uniformity, the high CT numbers linearity, geometric accuracy and relatively poor performance in low contrast resolution, compared to the results of plan CT. Additionally, the spatial resolution, the CT number linearity and the image uniformity proved to be more superior along the z direction and in the cross-section. Furthermore, the spatial resolution and the CT value linearity decreased gradually when deviating from the center of rotation axis and accelerates the reduction towards the periphery area, suggesting that locating the target within the range of 4 cm around the isocenter during radiotherapy ensure the optimal spatial resolution and the CT value linearity. Conclusions: Results indicate that the proposed three-dimensional image quality evaluation holds the potential to complement existing standards to provide sufficient information for the CBCT image performance and thereby guiding the clinical applications of CBCT.
引用
收藏
页码:189 / 202
页数:14
相关论文
共 50 条
  • [1] Three-dimensional analysis of the airway with cone-beam computed tomography
    Stratemann, Scott
    Huang, John C.
    Maki, Koutaro
    Hatcher, David
    Miller, Arthur J.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (05) : 607 - 615
  • [2] Morphofunctional evaluation of buccopharyngeal space using three-dimensional cone-beam computed tomography (3D-CBCT)
    Hinganu, Marius Valeriu
    Hinganu, Delia
    Cozma, Sebastian Romica
    Asimionoaiei-Simionescu, Cristina
    Scutariu, Irina Andreea
    Ionesi, Dorin Savin
    Haba, Danisia
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2018, 220 : 1 - 8
  • [3] Kilovoltage cone-beam computed tomography imaging dose estimation and optimization: Need of daily cone-beam computed tomography
    Trivedi, Gaurav
    Dixit, Chandra K.
    Oinam, Arun S.
    Kapoor, Rakesh
    Bahl, Amit
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (03) : 470 - 474
  • [4] A study on image quality provided by a kilovoltage cone-beam computed tomography
    Garayoa, Julia
    Castro, Pablo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01): : 239 - 257
  • [5] Assessment of three dead detector correction methods for cone-beam computed tomography
    Nelms, David W.
    Shukla, Hemant I.
    Nixon, Earl
    Bayouth, John E.
    Flynn, Ryan T.
    MEDICAL PHYSICS, 2009, 36 (10) : 4569 - 4576
  • [6] Prostatic artery embolization using three-dimensional cone-beam computed tomography
    Cadour, F.
    Tradi, F.
    Habert, P.
    Scemama, U.
    Vidal, V.
    Jacquier, A.
    Bartoli, J-M
    Moulin, G.
    Bessayah, A.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2020, 101 (11) : 721 - 725
  • [7] Essentials of Algebraic Reconstruction in Cone-Beam Computed Tomography
    Chernukha, A. E.
    Shestopalov, A. I.
    Adarova, A. I.
    Shershnev, R. V.
    Kizilova, Ya. V.
    Koryakin, S. N.
    Ivanov, S. A.
    Solovev, A. N.
    BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE, 2023, 50 (10) : 438 - 444
  • [8] Cone-beam computed tomography for trauma
    Gupta, Saurabh
    Martinson, James R.
    Ricaurte, Daniel
    Scalea, Thomas M.
    Morrison, Jonathan J.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2020, 89 (03) : E34 - E40
  • [9] Accuracy of three-dimensional printed models derived from cone-beam computed tomography
    Ferraro, Joshua M.
    Falter, Jacob
    Lee, Sanghee
    Watanabe, Keiichiro
    Wu, Tai-Hsien
    Kim, Do-Gyoon
    Ko, Ching-Chang
    Tanaka, Eiji
    Deguchi, Toru
    ANGLE ORTHODONTIST, 2022, 92 (06) : 722 - 727
  • [10] BREATH-HOLD TARGET LOCALIZATION WITH SIMULTANEOUS KILOVOLTAGE/MEGAVOLTAGE CONE-BEAM COMPUTED TOMOGRAPHY AND FAST RECONSTRUCTION
    Blessing, Manuel
    Stsepankou, Dzmitry
    Wertz, Hansjoerg
    Arns, Anna
    Lohr, Frank
    Hesser, Juergen
    Wenz, Frederik
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (04): : 1219 - 1226