Left ventricular mass assessed by three-dimensional echocardiography using rotational acquisition

被引:9
|
作者
Rodevand, O [1 ]
Bjornerheim, R [1 ]
Kolbjornsen, O [1 ]
Ihlen, H [1 ]
Kjekshus, J [1 ]
机构
[1] UNIV OSLO,RIKSHOSP,NATL HOSP,CTR CLIN EPIDEMIOL & STAT,N-0027 OSLO,NORWAY
关键词
three-dimensional ultrasound; echocardiography; three-dimensional reconstructions; left ventricular mass;
D O I
10.1002/clc.4960201111
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The reproducibility of left ventricular (LV) mass measurement by two-dimensional (2-D) echocardiography is inadequate for individual assessments. Hypothesis: This study was undertaken to evaluate the potential of LV mass determination with a new three-dimensional (3-D) echocardiographic method compared with 2-D measurements. Methods: Pot-cine agarose-filled left ventricles (n = 15, true mass 61-511 g) of different shapes were measured by a multiplane 3-D method based on 90 images acquired by probe rotation axis (1) perpendicular and (2) parallel to the ventricular long axis [''parasternal'' (the left sternal border was not present as a reference point in this study) and apical views]. Mass was also obtained using (3) the biplane truncated ellipsoid and (4) area-length methods, as well as (5) the modified cube formula. Five hearts were not analyzed with the apical 3-D technique because of insufficient image quality. Results: Systematic deviation from true mass was small with all methods (<5.3%). Accuracy, expressed as 1 standard deviation of individual estimates around this systematic bias, was 7.7, 13.6, 8.2, 11.9, and 11.9% of true mass for the methods 1-5, respectively. Interobserver reproducibility, expressed as the coefficient of variation, was 4.7, 8.8, 8.1, 8.9, and 9.4% for the same methods. Conclusion: Limits fur individual accuracy and reproducibility of LV mass estimates are nearly doubled using apical compared with ''parasternal'' 3-D echocardiography in vitro. A main advantage of ''parasternal'' 3-D compared with 2-D LV mass estimates is better reproducibility, but at the expense of greater time consumption. Apical 3-D technique is not superior to simpler 2-D methods based on ''parasternal'' short axis imaging.
引用
收藏
页码:957 / 962
页数:6
相关论文
共 50 条
  • [1] Normal Values of Left Ventricular Mass Index Assessed by Transthoracic Three-Dimensional Echocardiography
    Mizukoshi, Kei
    Takeuchi, Masaaki
    Nagata, Yasufumi
    Addetia, Karima
    Lang, Roberto M.
    Akashi, Yoshihiro J.
    Otsuji, Yutaka
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2016, 29 (01) : 51 - 61
  • [2] Left Ventricular Mass in 169 Healthy Children and Young Adults Assessed by Three-Dimensional Echocardiography
    T. Poutanen
    E. Jokinen
    Pediatric Cardiology, 2007, 28 : 201 - 207
  • [3] Left ventricular mass in 169 healthy children and young adults assessed by three-dimensional echocardiography
    Poutanen, T.
    Jokinen, E.
    PEDIATRIC CARDIOLOGY, 2007, 28 (03) : 201 - 207
  • [4] REAL-TIME THREE-DIMENSIONAL ECHOCARDIOGRAPHY FOR QUANTIFYING LEFT VENTRICULAR MASS
    Hong-wen Fei* Xin-fang Wang
    ChineseMedicalSciencesJournal, 2004, (03) : 230 - 232
  • [5] Three-Dimensional Echocardiography in Evaluation of Left Ventricular Indices
    Yamani, Hussein
    Cai, Qiangjun
    Ahmad, Masood
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (01): : 66 - 75
  • [6] Calculation of Pediatric Left Ventricular Mass: Validation and Reference Values Using Real-Time Three-Dimensional Echocardiography
    Laser, Kai Thorsten
    Houben, Britta Anna
    Koerperich, Hermann
    Haas, Nikolaus Alexander
    Kelter-Kloepping, Andrea
    Barth, Peter
    Burchert, Wolfgang
    DallaPozza, Robert
    Kececioglu, Deniz
    Herberg, Ulrike
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2015, 28 (03) : 275 - 283
  • [7] Theoretical estimation and measurement of accuracy and variability in Left ventricular volume and mass quantification using Three-Dimensional Echocardiography
    Nadkarni, SK
    Boughner, DR
    Drangova, M
    Fenster, A
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 673 - 675
  • [8] Left ventricular mass measured by myocardial perfusion gated SPECT - Relation to three-dimensional echocardiography
    Akinboboye, O
    Germano, G
    Idris, O
    Nichols, K
    Gopal, A
    Berman, D
    Bergmann, SR
    CLINICAL NUCLEAR MEDICINE, 2003, 28 (05) : 392 - 397
  • [9] Three-Dimensional Speckle Tracking Echocardiography for Evaluating Left Ventricular Rotation: An in vitro Validation Study using a Rotational Phantom Model
    Park, Austin
    Zhu, Meihua
    Kimura, Sumito
    Bleck, Rosie
    Amacher, Kacie
    Streiff, Cole
    Ravi, Sreyas
    Ashraf, Shahryar
    Ashraf, Muhammad
    Sahn, David J.
    CIRCULATION, 2013, 128 (22)
  • [10] Determination of left ventricular mass by real-time three-dimensional echocardiography: In vitro validation
    Takuma, S
    Cabreriza, SE
    Sciacca, R
    Di Tullio, MR
    Spotnitz, HM
    Homma, S
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2000, 17 (07): : 665 - 674