Major factors affecting the isotopic measurement of chlorine based on the CS2Cl+ ion by thermal ionization mass spectrometry

被引:10
|
作者
Xiao, YK [1 ]
Lu, H
Zhang, CG
Wang, QZ
Wei, HZ
Sun, A
Liu, WG
机构
[1] Acad Sinica, Qinghai Inst Salt Lakes, Xining 810008, Peoples R China
[2] Chinese Acad Sci, Inst Earth Environm, State Key Lab Loess & Quaternary Geol, Xian 710075, Peoples R China
关键词
D O I
10.1021/ac0107352
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The factors that affect isotopic measurement of chlorine based on Cs2Cl+ ion by thermal ionization mass spectrometry were studied. Graphite is essential for the emission of Cs2Cl+ ion from CsCl. No Cs2Cl+ ions are detected in the absence of graphite on the filament. The emission of Cs2Cl+ ion and the measured Cl-37/Cl-35 ratio were affected by different varieties of graphite, the pH value of the sample solution, and impurities in the solution. High-precision isotopic measurement of chlorine based on Cs2Cl+ ion is achieved only by using graphite with a perfect crystal structure. The measured Cl-37/Cl-35 ratios were much higher, and even the emission of Cs2Cl+ ion becomes impossible when pH values of the sample solution were higher than 6, corresponding to the presence of excess Cs. The measured Cl-37/Cl-35 ratios were higher when SO42- and NO3- anions were present. The results show that the measured Cl-37/Cl-35 ratios are weakly related to the amount of chlorine on filament in a range from 1 to 500 mug.
引用
收藏
页码:2458 / 2464
页数:7
相关论文
共 50 条
  • [21] Extraction and analysis of hydrosoluble chlorine and its stable isotopic composition in soil using thermal ionization mass spectrometry
    Liu, Lihua
    Mu, Shanliang
    Leng, Peng
    Dong, Yuliang
    Xu, Qingcai
    Sun, Aide
    CHEMICAL GEOLOGY, 2020, 558
  • [22] AN IMPROVED METHOD FOR THE HIGH-PRECISION ISOTOPIC MEASUREMENT OF BORON BY THERMAL IONIZATION MASS-SPECTROMETRY
    XIAO, YK
    BEARY, ES
    FASSETT, JD
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1988, 85 (02): : 203 - 213
  • [23] Extraction and Separation of Boron in Anhydrite and Gypsum Minerals and Its Isotopic Measurement by Thermal Ionization Mass Spectrometry
    Qin Zhan-Jie
    Zhang Xiang-Ru
    Peng Zhang-Kuang
    Li Qing-Kuan
    Ma Yun-Qi
    Fan Qi-Shun
    Du Yong-Sheng
    Wang Jian-Ping
    Shan Fa-Shou
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 46 (01) : 48 - 54
  • [24] A NEW METHOD FOR THE HIGH-PRECISION ISOTOPIC MEASUREMENT OF BROMINE BY THERMAL IONIZATION MASS-SPECTROMETRY
    XIAO, YK
    LIU, WG
    QI, HP
    ZHANG, CG
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 123 (02): : 117 - 123
  • [25] Precise Determination of the Absolute Isotopic Abundance Ratio and the Atomic Weight of Chlorine in Three International Reference Materials by the Positive Thermal Ionization Mass Spectrometer-Cs2Cl+-Graphite Method
    Wei, Hai-Zhen
    Jiang, Shao-Yong
    Xiao, Ying-Kai
    Wang, Jun
    Lu, Hai
    Wu, Bin
    Wu, He-Pin
    Li, Qing
    Luo, Chong-Guang
    ANALYTICAL CHEMISTRY, 2012, 84 (23) : 10350 - 10358
  • [26] High Precise Determination of Bromine Isotopic Ratios by Positive Thermal Ionization Mass Spectrometry Using Static Multicollection Based on Cs2Br+ Ions
    Ma Yun-Qi
    Peng Zhang-Kuang
    Chen Yan-Jiao
    Yang Jian
    Xiao Ying-Kai
    Zhang Yan-Ling
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (02) : 186 - 191
  • [27] DIRECT DETERMINATION OF BORON AND CHLORINE ISOTOPIC COMPOSITIONS IN GEOLOGICAL-MATERIALS BY NEGATIVE THERMAL-IONIZATION MASS-SPECTROMETRY
    VENGOSH, A
    CHIVAS, AR
    MCCULLOCH, MT
    CHEMICAL GEOLOGY, 1989, 79 (04) : 333 - 343
  • [28] Isotopic fractionation studies of uranium and plutonium using porous ion emitters as thermal ionization mass spectrometry sources
    Baruzzini, Matthew L.
    Hall, Howard L.
    Spencer, Khalil J.
    Stanley, Floyd E.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2018, 430 : 57 - 62
  • [29] A robust methodology for high precision isotopic analysis of boron by thermal ionization mass spectrometry using Na2BO2+ ion
    Rao, Radhika M.
    Parab, Ankush R.
    Sasibhushan, K.
    Aggarwal, Suresh K.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2009, 285 (03) : 120 - 125
  • [30] Determination of Stable Chlorine Isotopes by Isotopic Preparative Chromatography (IPC) with Positive-Thermal Ionization Mass Spectrometry (P-TIMS)
    Gui, Jianye
    Chen, Xi
    Han, Xiaodong
    Wang, Zhen
    Ma, Yunqi
    ANALYTICAL LETTERS, 2022, 55 (16) : 2564 - 2573