Major factors affecting the isotopic measurement of chlorine based on the CS2Cl+ ion by thermal ionization mass spectrometry

被引:10
|
作者
Xiao, YK [1 ]
Lu, H
Zhang, CG
Wang, QZ
Wei, HZ
Sun, A
Liu, WG
机构
[1] Acad Sinica, Qinghai Inst Salt Lakes, Xining 810008, Peoples R China
[2] Chinese Acad Sci, Inst Earth Environm, State Key Lab Loess & Quaternary Geol, Xian 710075, Peoples R China
关键词
D O I
10.1021/ac0107352
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The factors that affect isotopic measurement of chlorine based on Cs2Cl+ ion by thermal ionization mass spectrometry were studied. Graphite is essential for the emission of Cs2Cl+ ion from CsCl. No Cs2Cl+ ions are detected in the absence of graphite on the filament. The emission of Cs2Cl+ ion and the measured Cl-37/Cl-35 ratio were affected by different varieties of graphite, the pH value of the sample solution, and impurities in the solution. High-precision isotopic measurement of chlorine based on Cs2Cl+ ion is achieved only by using graphite with a perfect crystal structure. The measured Cl-37/Cl-35 ratios were much higher, and even the emission of Cs2Cl+ ion becomes impossible when pH values of the sample solution were higher than 6, corresponding to the presence of excess Cs. The measured Cl-37/Cl-35 ratios were higher when SO42- and NO3- anions were present. The results show that the measured Cl-37/Cl-35 ratios are weakly related to the amount of chlorine on filament in a range from 1 to 500 mug.
引用
收藏
页码:2458 / 2464
页数:7
相关论文
共 50 条
  • [1] HIGH-PRECISION ISOTOPIC MEASUREMENT OF CHLORINE BY THERMAL IONIZATION MASS-SPECTROMETRY OF THE CS2CL+ ION
    XIAO, YK
    ZHANG, CG
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 116 (03): : 183 - 192
  • [2] PRECISE MEASUREMENT OF CHLORINE ISOTOPES BASED ON CS2CL+ BY THERMAL IONIZATION MASS-SPECTROMETRY
    XIAO, YK
    ZHOU, YM
    LIU, WG
    ANALYTICAL LETTERS, 1995, 28 (07) : 1295 - 1304
  • [3] Emission Mechanism of Polyatomic Ions Cs2Cl+ and Cs2BO2+ in Thermal Ionization Mass Spectrometry with Various Carbon Materials
    Wei, Hai-Zhen
    Jiang, Shao-Yong
    Hemming, Gary N.
    Yang, Jing-Hong
    Xiao, Ying-Kai
    Yang, Tao
    Yan, Xiong
    Yan, Yan
    JOURNAL OF PHYSICAL CHEMISTRY A, 2011, 115 (51): : 14570 - 14580
  • [4] Precise measurement of chlorine stable isotopic ratios by thermal ionization mass spectrometry
    Numata, M
    Nakamura, N
    Gamo, T
    GEOCHEMICAL JOURNAL, 2001, 35 (02) : 89 - 100
  • [5] MAJOR FACTORS AFFECTING THE EMISSION OF DILITHIUM-FLUORIDE CLUSTER ION IN THERMAL IONIZATION MASS SPECTROMETRY
    Dustebek, Jasmina
    Veljkovic, Miomir
    Velickovic, Suzana
    DIGEST JOURNAL OF NANOMATERIALS AND BIOSTRUCTURES, 2013, 8 (01) : 359 - 366
  • [6] Precise measurement of chlorine isotopes by thermal ionization mass spectrometry
    Neskovic, OM
    Veljkovic, NV
    Velickovic, SR
    Deric, AJ
    Miljevic, NR
    Golobocanin, DD
    NUKLEONIKA, 2002, 47 : S85 - S87
  • [7] Measurement of chlorine stable isotopic composition by negative thermal ionization mass spectrometry using total evaporation technique
    Fujitani, Tatsuya
    Yamashita, Katsuyuki
    Numata, Masahiko
    Kanazawa, Nobuyuki
    Nakamura, Noboru
    GEOCHEMICAL JOURNAL, 2010, 44 (03) : 241 - 246
  • [8] High precision isotopic measurement of lithium by thermal ionization mass spectrometry
    Sahoo, SK
    Masuda, A
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 151 (2-3): : 189 - 196
  • [9] Measurement of cesium isotopic ratio by thermal ionization mass spectrometry for neutron capture reaction studies on 135Cs
    Shibahara, Yuji
    Nakamura, Shoji
    Uehara, Akihiro
    Fujii, Toshiyuki
    Fukutani, Satoshi
    Kimura, Atsushi
    Iwamoto, Osamu
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2020, 325 (01) : 155 - 165
  • [10] Measurement of cesium isotopic ratio by thermal ionization mass spectrometry for neutron capture reaction studies on 135Cs
    Yuji Shibahara
    Shoji Nakamura
    Akihiro Uehara
    Toshiyuki Fujii
    Satoshi Fukutani
    Atsushi Kimura
    Osamu Iwamoto
    Journal of Radioanalytical and Nuclear Chemistry, 2020, 325 : 155 - 165