Optimized Imaging of the Postoperative Spine

被引:19
作者
McLellan, Anne Marie [1 ]
Daniel, Simon [1 ]
Corcuera-Solano, Idoia [1 ]
Joshi, Vivek [1 ]
Tanenbaum, Lawrence N. [1 ]
机构
[1] Icahn Sch Med Mt Sinai, Dept Neuroradiol, New York, NY 10029 USA
关键词
Spine; Spine hardware; Postoperative spine; Dual energy; MR imaging; CT; SQUARES ESTIMATION IDEAL; ITERATIVE DECOMPOSITION; CLINICAL-APPLICATIONS; ARTIFACT CORRECTION; METALLIC ARTIFACTS; ECHO ASYMMETRY; MRI; IMPLANTS; PRINCIPLES; WATER;
D O I
10.1016/j.nic.2014.01.005
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Few tasks in imaging are more challenging than that of optimizing evaluations of the instrumented spine. The authors describe how applying fundamental and more advanced principles to postoperative spine computed tomography and magnetic resonance examinations mitigates the challenges associated with metal implants and significantly improves image quality and consistency. Newer and soon-to-be-available enhancements should provide improved visualization of tissues and hardware as multispectral imaging sequences continue to develop.
引用
收藏
页码:349 / +
页数:17
相关论文
共 24 条
[1]  
Awh M., 2011, MRI WEB CLIN
[2]  
BYDDER G M, 1985, Magnetic Resonance Imaging, V3, P251, DOI 10.1016/0730-725X(85)90354-6
[3]   MR imaging near metal with undersampled 3D radial UTE-MAVRIC sequences [J].
Carl, Michael ;
Koch, Kevin ;
Du, Jiang .
MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) :27-36
[4]   Practical Application of Iterative Decomposition of Water and Fat with Echo Asymmetry and Least-Squares Estimation (IDEAL) Imaging in Minimizing Metallic Artifacts [J].
Cha, Jang Gyu ;
Hong, Hyun Sook ;
Park, Jai Soung ;
Paik, Sang Hyun ;
Lee, Hae Kyung .
KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (03) :332-341
[5]   New MR Imaging Methods for Metallic Implants in the Knee: Artifact Correction and Clinical Impact [J].
Chen, Christina A. ;
Chen, Weitian ;
Goodman, Stuart B. ;
Hargreaves, Brian A. ;
Koch, Kevin M. ;
Lu, Wenmaio ;
Brau, Anja C. ;
Draper, Christine E. ;
Delp, Scott L. ;
Gold, Garry E. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (05) :1121-1127
[6]   Body MRI using IDEAL [J].
Costa, Daniel N. ;
Pedrosa, Ivan ;
McKenzie, Charles ;
Reeder, Scott B. ;
Rofsky, Neil M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (04) :1076-1084
[7]   RF aitifacts caused by metallic implants or instruments which get more prominent at 3 T: an in vitro study [J].
Graf, H ;
Lauer, UA ;
Berger, A ;
Schick, F .
MAGNETIC RESONANCE IMAGING, 2005, 23 (03) :493-499
[8]   Metallic artefacts in MR imaging: Effects of main field orientation and strength [J].
Guermazi, A ;
Miaux, Y ;
Zaim, S ;
Peterfy, CG ;
White, D ;
Genant, HK .
CLINICAL RADIOLOGY, 2003, 58 (04) :322-328
[9]   Metallic artefact reduction with monoenergetic dual-energy CT: systematic ex vivo evaluation of posterior spinal fusion implants from various vendors and different spine levels [J].
Guggenberger, R. ;
Winklhofer, S. ;
Osterhoff, G. ;
Wanner, G. A. ;
Fortunati, M. ;
Andreisek, G. ;
Alkadhi, H. ;
Stolzmann, P. .
EUROPEAN RADIOLOGY, 2012, 22 (11) :2357-2364
[10]   Metal-Induced Artifacts in MRI [J].
Hargreaves, Brian A. ;
Worters, Pauline W. ;
Pauly, Kim Butts ;
Pauly, John M. ;
Koch, Kevin M. ;
Gold, Garry E. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) :547-555