Analysis of 7 synthetic musks in cream by supported liquid extraction and solid phase extraction followed by GC-MS/MS

被引:16
作者
Dong, Haifeng [1 ]
Tang, Hua [2 ]
Chen, Dazhou [2 ]
Xu, Ting [1 ]
Li, Lei [1 ]
机构
[1] Beijing Univ Chem Technol, State Key Lab Chem Resource Engn, Beijing 100029, Peoples R China
[2] Natl Inst Metrol, Div Metrol Chem, Beijing 100013, Peoples R China
关键词
Cream; Synthetic musks; SLE; SPE; GC-MS/MS; CHROMATOGRAPHY-MASS SPECTROMETRY; PERSONAL CARE PRODUCTS; GAS-CHROMATOGRAPHY; NITRO-MUSKS; FRAGRANCES; MICROEXTRACTION; MS; OPTIMIZATION; KETONE; WATERS;
D O I
10.1016/j.talanta.2013.11.086
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method for the simultaneous determination of 7 synthetic musks (musk amberette, musk tibetene, musk moskene, musk ketone, musk xylene, phantolide, and tonalide) in cream by means of supporting liquid extraction (SLE) coupled with LC-Alumina-N SPE, then followed by GC-MS/MS has been established. In this study, 7 synthetic musks are extracted and pre-purified by a mixture solution of water and isopropanol from cream, and separated and purified by tandem columns containing SLE column and LC-Alumina-N SPE column, which were seldom reported before. Ultrasonic and mechanical shaking were applied to improve the extraction efficiency. Different experiment conditions, such as the type of extraction solution, extraction time of ultrasonic and mechanical shaking, the type of SLE and SPE column, and matrix effects were optimized and the recoveries of 7 synthetic musks for each part were above 86.61%. In addition, the use of isotope internal standards was systemically discussed. The method showed satisfactory linearity over the range assayed (5-1000 ng g(-1)), and the limits of detections (LODs) ranged from 0.15 to 4.86 ng g(-1), and the limits of quantifications (LOQs) were ranging from 0.49 to 16.21 ng g(-1). The recoveries using this method at three spiked concentration levels (10, 100, and 1000 ng g(-1)) range from 85.6% to 109%. The relative standard deviation was lower than 9.8% in all case. The proposed analytical method has been successfully applied for the analysis of 7 synthetic musks in commercial cream. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:248 / 254
页数:7
相关论文
共 44 条
[1]   Relating electrospray ionization response to nonpolar character of small peptides [J].
Cech, NB ;
Enke, CG .
ANALYTICAL CHEMISTRY, 2000, 72 (13) :2717-2723
[2]  
David F, 2003, HANDB ENVIRON CHEM, V3, P9
[3]  
Dietrich DR, 2004, HANDB ENVIRON CHEM, V3, P233
[4]   A comparative study of five nitro musk compounds for genotoxicity in the SOS chromotest and Salmonella mutagenicity [J].
Emig, M ;
Reinhardt, A ;
MerschSundermann, V .
TOXICOLOGY LETTERS, 1996, 85 (03) :151-156
[5]  
Gautschi M, 2001, CHIMIA, V55, P379
[6]   Simple and rapid determination of norethindrone in human plasma by supported liquid extraction and ultra performance liquid chromatography with tandem mass spectrometry [J].
Gong, Zhilong ;
Chandler, Kiresha ;
Webster, Stephen ;
Kerley, Remy ;
Buist, Susan ;
McCort-Tipton, Melanie .
TALANTA, 2012, 91 :77-82
[7]   Utilization of homogeneous liquid-liquid extraction followed by HPLC-UV as a sensitive method for the extraction and determination of phthalate esters in environmental water samples [J].
Hadjmohammadi, Mohammad Reza ;
Ranjbari, Elias .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2012, 92 (11) :1285-1297
[8]   Simple extractive derivatization of methamphetamine and its metabolites in biological materials with Extrelut(R) columns for their GC-MS determination [J].
Hara, K ;
Kashimura, S ;
Hieda, Y ;
Kageura, M .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1997, 21 (01) :54-58
[9]   Suitability of a fully 13C isotope labeled internal standard for the determination of the mycotoxin deoxynivalenol by LC-MS/MS without clean up [J].
Häubl, G ;
Berthiller, F ;
Krska, R ;
Schuhmacher, R .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (03) :692-696
[10]   LC-Electron capture APCI-MS for the determination of nitroaromatic compounds [J].
Hayen, H ;
Jachmann, N ;
Vogel, M ;
Karst, U .
ANALYST, 2002, 127 (08) :1027-1030