Design of thermoelectric radiant cooling-photovoltaic panels system in the building

被引:2
作者
Abdulghafor, Israa Ali [1 ]
Mnati, Mohannad Jabbar [1 ]
机构
[1] Middle Tech Univ, Inst Technol Baghdad, Baghdad 10074, Iraq
关键词
Thermoelectric panels; Cooling capacity; Numerical calculations; PV system; AIR; PERFORMANCE; WINDOW;
D O I
10.24425/ather.2022.144407
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, a theoretical model is presented to investigate the performance of a thermoelectric (TE) radiant cooling system combined with photovoltaic (PV) modules as a power supply in a building with an am-bient temperature reaching more than 45 degrees C. The combined system TE/PV performance is studied under different solar radiation by using the hourly analysis program and photovoltaic system software. The thermal and elec-tric characteristics of TE are theoretically investigated under various sup-plied voltages using the multi-paradigm programming language and numer-ical computing environment. Also, a theoretical analysis of heat transfer between the TE radiant cooling system and an occupied zone from the side, and the other side between the TE radiant cooling system and duct zone is presented. The maximum power consumption by TE panels and building cooling load of 130 kW is predicted for May and June. The 145 units of PV panels could provide about 50% of the power required by TE panels. The thermal and electric characteristics of TE panels results show the min-imum cold surface temperature of 15 degrees C at a supplied voltage between 6 V and 7 V, and the maximum hot surface temperature of 62 degrees C at a supplied voltage of 16 V. The surface temperature difference between supplied cur-rent and supplied power increases as supplied voltage increases. At a higher supplied voltage of 16 V, the maximum surface temperature difference be-tween supplied current, and supplied power of 150 degrees C, 3.2 A, and 48 W, respectively. The cooling capacity increases as supplied voltage increases, at a surface temperature difference of -10 degrees C and supplied voltage of 16 V, the maximum cooling capacity is founded at about 60 W. As supplied voltage decreases the coefficient of performance increases. The maximum coefficient of performance is about 5 at the surface temperature difference of -10 degrees C and supplied voltage of 8 V.
引用
收藏
页码:85 / 108
页数:24
相关论文
共 24 条
[1]   Thermal performance evaluation of an earth-to-air heat exchanger for the heating mode applications using an experimental test rig [J].
Ahmad, Saif Nawaz ;
Prakash, Om .
ARCHIVES OF THERMODYNAMICS, 2022, 43 (01) :185-207
[2]   Assessing the performance of the airflow window for ventilation and thermal comfort in office rooms [J].
Ajirlou, Ildar fathi ;
Kurtay, Cuneyt .
ARCHIVES OF THERMODYNAMICS, 2021, 42 (03) :209-242
[3]   A Study on Thermal and Electrical Characteristics of Thermoelectric Cooler TEC1-127 Series [J].
Akram, M. N. ;
Nirmani, H. R. ;
Jayasundere, N. D. .
2016 7TH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS, MODELLING AND SIMULATION (ISMS), 2016, :430-434
[4]  
American Society of Heating Refrigerating and Air-Conditioning Engineers, 2012, ASHRAE HDB
[5]  
[Anonymous], HAP 4 6 SOFTW
[6]  
[Anonymous], 2015, MATLAB SOFTWARE
[7]  
[Anonymous], PVSYST SOFTW 7 2
[8]  
AutoCAD Software, 2018, AUTOCAD SOFTW
[9]   Optimization of absorption refrigeration systems by the method of computational experiment design [J].
Ben Iffa, Ridha ;
Kairouani, Lakdar ;
Bouaziz, Nahla .
ARCHIVES OF THERMODYNAMICS, 2019, 40 (01) :85-102
[10]   Refrigerants and their environmental impact Substitution of hydro chlorofluorocarbon HCFC and HFC hydro fluorocarbon. Search for an adequate refrigerant [J].
Benhadid-Dib, Samira ;
Benzaoui, Ahmed .
TERRAGREEN 2012: CLEAN ENERGY SOLUTIONS FOR SUSTAINABLE ENVIRONMENT (CESSE), 2012, 18 :807-816