Experimental and numerical investigation of forced convection in a double skin facade by using nodal network approach for Istanbul

被引:38
作者
Inan, Tugba [1 ,2 ]
Basaran, Tahsin [2 ]
机构
[1] Nigde Omer Halisdemir Univ, Dept Architecture, TR-51240 Nigde, Turkey
[2] Izmir Inst Technol, Dept Architecture, TR-35430 Izmir, Turkey
关键词
Double skin fa ade; Forced convection; Nodal network; Solar radiation; ENERGY PERFORMANCE; TEMPERATE CLIMATES;
D O I
10.1016/j.solener.2019.03.030
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, temperature distribution and heat transfer through the cavity of a double skin facade (DSF) was investigated in the laboratory environment and analyzed numerically by using nodal network approach. The verification of the nodal network method was conducted by using data from the steady-state experiments and the same method was applied for the climate of Istanbul, Turkey under unsteady outside boundary conditions. Furthermore, heat gain and loss values in DSF for January and July were calculated and compared with single skin facade (SSF) application for different directions of the facades. The results were given for a day and a working time period of the office buildings by using monthly average daily climate data. Distinction working hours were more convenient to investigate the energy performance of DSF because of solar radiation effect. Using DSF in all directions, the cooling loads decreased up to 26% comparing to the SSF. DSF system was disadvantageous comparing to the SSF for January. However, it was shown that the heated air in the cavity could be used for preheating process of air in a HVAC system for winter period.
引用
收藏
页码:441 / 452
页数:12
相关论文
共 21 条
[1]   Experimental investigation of the pressure loss through a double skin facade by using perforated plates [J].
Basaran, Tahsin ;
Inan, Tugba .
ENERGY AND BUILDINGS, 2016, 133 :628-639
[2]  
Cengel Y.A., 2007, HEAT MASS TRANSFER
[3]   Investigation on energy performance of double skin facade in Hong Kong [J].
Chan, A. L. S. ;
Chow, T. T. ;
Fong, K. F. ;
Lin, Z. .
ENERGY AND BUILDINGS, 2009, 41 (11) :1135-1142
[4]  
Eicker U., 2003, SOLAR TECHNOLOGIES B
[5]   Experimental study of a mechanically ventilated double-skin facade with venetian sun-shading device: A full-scale investigation in controlled environment [J].
Gavan, Valentin ;
Woloszyn, Monika ;
Kuznik, Frederic ;
Roux, Jean-Jacques .
SOLAR ENERGY, 2010, 84 (02) :183-195
[6]   Exploring the advantages and challenges of double-skin facades (DSFs) [J].
Ghaffarianhoseini, Ali ;
Ghaffarianhoseini, Amirhosein ;
Berardi, Umberto ;
Tookey, John ;
Li, Danny Hin Wa ;
Kariminia, Shahab .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 60 :1052-1065
[7]   Simulation of ventilated facades in hot and humid climates [J].
Haase, M. ;
da Silva, F. Marques ;
Amato, A. .
ENERGY AND BUILDINGS, 2009, 41 (04) :361-373
[8]   Double versus single skin facades in hot and areas [J].
Hamza, Neveen .
ENERGY AND BUILDINGS, 2008, 40 (03) :240-248
[9]   Prediction of solar heat gain of double skin facade windows [J].
He, Guoqing ;
Xu, Jianfeng ;
Zheng, Yun ;
Zhang, Sanming ;
Bai, Qi'an .
BUILDING SIMULATION, 2016, 9 (04) :399-409
[10]  
Inan T, 2016, THESIS