The use of a radiofrequency unit for harvesting conjunctival autografts in pterygium surgery

被引:8
作者
Camara, JG [1 ]
dela Cruz-Rosas, B [1 ]
Nguyen, LT [1 ]
机构
[1] Univ Hawaii, John A Burns Sch Med, Dept Surg, Div Ophthalmol, Honolulu, HI 96822 USA
关键词
D O I
10.1016/j.ajo.2004.02.028
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To describe a simplified technique for harvesting a conjunctival autograft using a radiofrequency unit. DESIGN: Retrospective, noncomparative, interventional case series. METHOD: The use of radiofrequency to harvest a thin, bloodless conjunctival autograft is described. A retrospective review of 171 primary pterygium procedures on 151 patients seen between April 1998 and December 2001 was done. All surgeries were performed by one surgeon (J.G.C.). All cases had a minimum follow-up of 12 months. RESULTS: Surgery was completed successfully with no complications in all 171 cases. Recurrence was noted in only 8 cases (4.6%). CONCLUSIONS: The use of radiofrequency to harvest a conjunctival autograft in pterygium surgery is effective and safe. (C) 2004 by Elsevier Inc. All rights reserved.
引用
收藏
页码:165 / 167
页数:3
相关论文
共 8 条
[1]  
BROWN J, 2000, MINOR SURG TEXT ATLA, P311
[2]  
HURWITZ JJ, 1993, CAN J OPHTHALMOL, V28, P28
[3]   THE ENDOSCOPE AND THE RADIOFREQUENCY UNIT IN DCR SURGERY [J].
JAVATE, RM ;
CAMPOMANES, BSA ;
CO, ND ;
DINGLASAN, JL ;
GO, CG ;
TAN, EN ;
TAN, FE .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1995, 11 (01) :54-58
[4]  
Kammoun B, 2001, J FR OPHTALMOL, V24, P823
[5]  
KENYON KR, 1985, OPHTHALMOLOGY, V92, P1461
[6]   A comparative study of recurrent pterygium surgery -: Limbal conjunctival autograft transplantation versus mitomycin C with conjunctival flap [J].
Mutlu, FM ;
Sobaci, G ;
Tatar, T ;
Yildirim, E .
OPHTHALMOLOGY, 1999, 106 (04) :817-821
[7]  
SPERLI A, 1996, INT J PLASTIC AESTHE, V11, P21
[8]   Use of mitomycin C with conjunctival autograft in pterygium surgery in Asian-Canadians [J].
Wong, VA ;
Law, FCH .
OPHTHALMOLOGY, 1999, 106 (08) :1512-1515