Evaluation of myocardial infarction size with three-dimensional speckle tracking echocardiography: a comparison with single photon emission computed tomography

被引:8
|
作者
Wang, Qiushuang [1 ]
Zhang, Chunhong [1 ]
Huang, Dangsheng [1 ]
Zhang, Liwei [1 ]
Yang, Feifei [1 ]
An, Xiuzhi [1 ]
Ouyang, Qiaohong [2 ]
Zhang, Meiqing [2 ]
Wang, Shuhua [1 ]
Guo, Jiarui [1 ]
Ji, Dongdong [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Cardiol, Affiliated Hosp 1, Beijing 100048, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Dept Nucl Med, Affiliated Hosp 1, Beijing 100048, Peoples R China
关键词
Three-dimensional speckle tracking echocardiography; Myocardial strain; Myocardial infarction; Area; Single photon emission computed tomography; CARDIOVASCULAR RISK-FACTORS; LEFT-VENTRICULAR FUNCTION; 2-DIMENSIONAL STRAIN; AREA STRAIN; QUANTIFICATION; DEFORMATION; INDEX;
D O I
10.1007/s10554-015-0745-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess whether global and regional myocardial strains from three-dimensional speckle tracking echocardiography (3D-STE) correlate with myocardial infarction size (MIS) detected by single photon emission computed tomography (SPECT). Fifty-seven patients with a history of ST-segment elevation myocardial infarction (MI) within 3-6 months were enrolled, alongside 24 healthy volunteers. Left ventricular (LV) global area strain, global longitudinal strain (GLS), global radial strain, global circumferential strain, left ventricular ejection fraction (LVEF) and wall motion score index (WMSI) were measured and compared with the corresponding SPECT-detected MISs. Patients were sub-grouped into massive MIS group (MIS a parts per thousand yen 12 %) and small MIS group (MIS < 12 %). Myocardial strains of all the LV segments were compared with the corresponding MIS. Global myocardial strain parameters, LVEF and WMSI of the patients were significantly different from the control group (all P < 0.05) and correlated well with MISs, most significantly for GLS (r = 0.728, P < 0.01). Significant differences in myocardial strain parameters were found between the massive and small MIS groups (all P < 0.05). Receiver operating characteristic curve analysis indicated that GLS had a highest diagnostic value and when the cutoff was -13.8 %, the area under the curve was 0.84, with the 70.6 % sensitivity and 87.5 % specificity. Significant differences of myocardial strain parameters were observed between segments with and without transmural MIs (P < 0.01). 3D-STE myocardial strain parameters evaluated LV global MIS, 3D GLS had the highest diagnostic value. It also preliminarily gauged the degree of ischemia and necrosis of regional myocardial segments.
引用
收藏
页码:1571 / 1581
页数:11
相关论文
共 50 条
  • [31] Three-Dimensional Speckle Tracking Echocardiography - A Promising Tool for Cardiac Functional Analysis
    Seo, Yoshihiro
    Ishizu, Tomoko
    Atsumi, Akiko
    Kawamura, Ryo
    Aonuma, Kazutaka
    CIRCULATION JOURNAL, 2014, 78 (06) : 1290 - 1301
  • [32] Imaging Evaluation in Otosclerosis: Single Photon Emission Computed Tomography and Computed Tomography
    Berrettini, Stefano
    Ravecca, Francesca
    Volterrani, Duccio
    Neri, Emanuele
    Forli, Francesca
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2010, 119 (04) : 215 - 224
  • [33] Comparison of Three-Dimensional Speckle Tracking Echocardiography and Two-Dimensional Echocardiography for Evaluation of Left Atrial Size and Function in Healthy Volunteers (Results from the MAGYAR-Healthy Study)
    Nemes, Attila
    Domsik, Peter
    Kalapos, Anita
    Lengyel, Csaba
    Orosz, Andrea
    Forster, Tamas
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (07): : 865 - 871
  • [34] Global and Regional Right Ventricular Function Assessed by Novel Three-Dimensional Speckle-Tracking Echocardiography
    Ishizu, Tomoko
    Seo, Yoshihiro
    Atsumi, Akiko
    Tanaka, Yumiko Oishi
    Yamamoto, Masayoshi
    Machino-Ohtsuka, Tomoko
    Horigome, Hitoshi
    Aonuma, Kazutaka
    Kawakami, Yasushi
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2017, 30 (12) : 1203 - 1213
  • [35] Three-dimensional speckle tracking echocardiography for the preclinical diagnosis of hypertrophic cardiomyopathy
    Aly, Mohamed F. A.
    Brouwer, Wessel P.
    Kleijn, Sebastiaan A.
    van Rossum, Albert C.
    Kamp, Otto
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (03) : 523 - 533
  • [36] Single-photon emission computed tomography as a fundamental tool in evaluation of myocardial reparation and regeneration therapies
    Tekieli, Lukasz
    Szot, Wojciech
    Kwiecien, Ewa
    Mazurek, Adam
    Borkowska, Eliza
    Czyz, Lukasz
    Dabrowski, Maciej
    Kozynacka, Anna
    Skubera, Maciej
    Podolec, Piotr
    Majka, Marcin
    Kostkiewicz, Magdalena
    Musialek, Piotr
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2022, 18 (04): : 326 - 339
  • [37] Evaluation of left atrial and ventricular myocardial functions by three-dimensional speckle tracking echocardiography in patients with euthyroid Hashimoto's thyroiditis
    Dogdus, Mustafa
    Diker, Suleyman
    Yenercag, Mustafa
    Gurgun, Cemil
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (02) : 459 - 465
  • [38] Three-dimensional speckle tracking echocardiography for the assessment of left ventricular function and mechanical dyssynchrony
    Kang, Yu
    Sun, Min-Min
    Cui, Jie
    Chen, Hai-Yan
    Su, Yan-Gang
    Pan, Cui-Zhen
    Shu, Xian-Hong
    ACTA CARDIOLOGICA, 2012, 67 (04) : 423 - 430
  • [39] Differentiation of myocardial ischemia and infarction assessed by dynamic computed tomography perfusion imaging and comparison with cardiac magnetic resonance and single-photon emission computed tomography
    Yuki Tanabe
    Teruhito Kido
    Teruyoshi Uetani
    Akira Kurata
    Tamami Kono
    Akiyoshi Ogimoto
    Masao Miyagawa
    Tsutomu Soma
    Kenya Murase
    Hirotaka Iwaki
    Teruhito Mochizuki
    European Radiology, 2016, 26 : 3790 - 3801
  • [40] Development of Quantitative Norms for Normal Lung Uptake Based on Three-Dimensional Gallium-67 Single Photon Emission Computed Tomography/Computed Tomography
    Chuang, Tzyy-Ling
    Li, Wei-Lin
    Hs, Yu-Ching
    Chen, Jyh-Cheng
    Wang, Yuh-Feng
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2024, 44 (05) : 696 - 703