Investigation of decoupling of thermal and electrical performance of semi-transparent photovoltaic windows based on the external quantum efficiency

被引:10
|
作者
Zhou, Hao [1 ,2 ]
Peng, Jinqing [1 ,2 ]
Wilson, Helen Rose [3 ]
Wang, Meng [4 ]
Jonsson, Jacob [5 ]
Ma, Tao [6 ]
Wu, Ben [7 ]
Wu, Bochao [1 ,2 ]
Fu, Ganhua [8 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Hunan, Peoples R China
[2] Hunan Univ, Key Lab Bldg Safety & Energy Efficiency, Minist Educ, Changsha, Hunan, Peoples R China
[3] Fraunhofer Inst Solar Energy Syst, Heidenhof str 2, D-79110 Freiburg, Germany
[4] Changsha Univ Sci & Technol, Sch Energy & Power Engn, Changsha 410114, Hunan, Peoples R China
[5] Lawrence Berkeley Natl Lab, Bldg Technol & Urban Syst Div, 1 Cyclotron Rd, Berkeley, CA 94720 USA
[6] Shanghai Jiao Tong Univ, Sch Mech Engn, Shanghai 200240, Peoples R China
[7] Adv Solar Power Hangzhou Inc, Hangzhou 310018, Zhejiang, Peoples R China
[8] CNBM Chengdu Optoelect Mat Co Ltd, Chengdu 610207, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Building-integrated photovoltaic (BIPV); Semi-transparent photovoltaic (STPV); window; External quantum efficiency (EQE); Solar heat gain coefficient (SHGC); Thermoelectric decoupling; DOUBLE-SKIN FACADE; ENERGY PERFORMANCE; CLIMATE ZONES; BUILDINGS; OFFICE; SYSTEM; BIPV; MODULES; MODEL;
D O I
10.1016/j.enbuild.2022.112539
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Semi-transparent photovoltaic (STPV) windows have great potential in buildings energy saving due to their power generation and reduction of buildings energy consumption. STPV windows have a complex optical-thermal-electrical coupling mechanism. However, previous studies have rarely considered the coupling mechanism when simulating the thermal and electrical performance of STPV windows, which has resulted in the power generation being incorrectly treated as waste heat. As has been mentioned in EN 50583:2016 and IEC 63092:2020, the calculation of thermal performance of STPV windows should consider the mechanism that part of absorbed solar energy is transformed into electricity rather than heat. With considering the mechanism, based on the external quantum efficiency (EQE) of solar cells, a decoupled optical, thermal, and electrical performance simulation method for STPV windows was pro-posed in this study. Firstly, the optical characteristics of STPV windows and the EQE of the integrated solar cells were measured by a spectrophotometer and a monochromatic incident photon-to-electron conversion efficiency (IPCE) testing device, respectively. The EQE was used to calculate the spectral pho-toelectric conversion efficiency (SPCE) of STPV windows. Then, the SPCE was subtracted from the original absorptance and added to the front reflectance at corresponding wavelength, thereby decoupling the thermal and electrical performance. To verify the importance of the decoupling, the thermal and electri-cal performance of STPV windows with and without decoupling were investigated using EnergyPlus and WINDOW programs. An outdoor experimental rig was used to validate the simulation results of EnergyPlus, it was found that the decoupled results match well with experimental results. The simulation results show that in the coupled case, the window temperature and cooling load were overestimated, while the heating load was underestimated. However, the impact on power generation was negligible due to the low temperature coefficient of efficiency. Besides, for the analyzed STPV glazing configuration, the solar heat gain coefficient (SHGC) of the coupled case is relatively 9.3% higher than that of the decou-pled case, when the solar cell coverage ratio is 70%. Moreover, the decoupled calculation method provides a theoretical basis for more accurate simulation and overall performance evaluation of STPV windows in maximum power point (MPP) state.(c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] The Influence of Photovoltaic Cell Coverage Rate on the Thermal and Electric Performance of Semi-Transparent Crystalline Silicon Photovoltaic Windows Based on the Dynamic Power Coupling Model
    Zhang, Wenjie
    Liu, Kangyong
    Ma, Shengbin
    Gong, Tongdan
    Zhao, Yingbo
    ENERGIES, 2021, 14 (21)
  • [2] Comparison of the overall energy performance of semi-transparent photovoltaic windows and common energy-efficient windows in Hong Kong
    Zhang, Weilong
    Lu, Lin
    Peng, Jinqing
    Song, Aotian
    ENERGY AND BUILDINGS, 2016, 128 : 511 - 518
  • [3] Analysis of thermal and electrical performance of semi-transparent photovoltaic (PV) module
    Park, K. E.
    Kang, G. H.
    Kim, H. I.
    Yu, G. J.
    Kim, J. T.
    ENERGY, 2010, 35 (06) : 2681 - 2687
  • [4] Thermal and Electrical Characterization of a Semi-Transparent Dye-Sensitized Photovoltaic Module under Real Operating Conditions
    Cornaro, Cristina
    Renzi, Ludovica
    Pierro, Marco
    Di Carlo, Aldo
    Guglielmotti, Alessandro
    ENERGIES, 2018, 11 (01):
  • [5] Optimal design of inhomogeneous semi-transparent photovoltaic windows based on daylight performance and visual characters
    Li, Xinyi
    Peng, Jinqing
    Tan, Yutong
    He, Yingdong
    Li, Bojia
    Ju, Xiaolei
    Ji, Jie
    Zhang, Song
    Li, Nianping
    Chen, Youming
    ENERGY AND BUILDINGS, 2023, 283
  • [6] Experimental and numerical study on the annual performance of semi-transparent photovoltaic glazing in different climate zones
    Wu, Zhenghong
    Zhang, Ling
    Wu, Jing
    Liu, Zhongbing
    ENERGY, 2022, 240
  • [7] Investigation of thermal performance of semi-transparent PV technologies
    Skandalos, N.
    Karamanis, D.
    ENERGY AND BUILDINGS, 2016, 124 : 19 - 34
  • [8] Comparative study of the thermal and power performances of a semi-transparent photovoltaic facade under different ventilation modes
    Peng, Jinqing
    Lu, Lin
    Yang, Hongxing
    Ma, Tao
    APPLIED ENERGY, 2015, 138 : 572 - 583
  • [9] Daylight performance of perimeter office facades utilizing semi-transparent photovoltaic windows: a simulation study
    Kapsis, K.
    Dermardiros, V.
    Athienitis, A. K.
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 334 - 339
  • [10] Daylighting and overall energy performance of a novel semi-transparent photovoltaic vacuum glazing in different climate zones
    Qiu, Changyu
    Yang, Hongxing
    APPLIED ENERGY, 2020, 276 (276)