Influence of ground waste clay brick on properties of fresh and hardened concrete

被引:151
作者
Ge, Zhi [1 ]
Wang, Yuanyuan [1 ]
Sun, Renjuan [1 ]
Wu, Xinsheng [1 ]
Guan, Yanhua [1 ]
机构
[1] Shandong Univ, Sch Civil Engn, Dept Transportat Engn, Jinan 250061, Peoples R China
基金
中国国家自然科学基金;
关键词
Clay-brick-powder; Workability; Mechanical properties; Static elastic modulus; Chloride ion penetrability; Autogenous shrinkage; Non-evaporable water; RECYCLED AGGREGATE; COARSE AGGREGATE; CRUSHED BRICKS; DURABILITY; MORTAR;
D O I
10.1016/j.conbuildmat.2015.08.100
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The influences of partially replacing cement with ground clay-brick on properties of fresh and hardened concrete were investigated. In this study, three different replacement levels (10%, 20%, and 30%) and three types of clay-brick-powder (CBP) with different particle sizes (Type A, B, and C) were adopted. The test results show that CBP reduced the slump of fresh concrete significantly as the replacement level was over 10%. All concrete specimens had similar density around 2400-2500 kg/m(3). As the replacement level increased, the early age strength decreased. However, as the curing age increased, strength of concrete with CBP was similar to that of reference concrete. Most concrete containing CBP had 90-day compressive strength over 50 MPa, 28-day flexural strength in the range of 10-12 MPa, and 28-day splitting tensile strength of 2-4 MPa. Static elastic modulus was between 15 and 30 GPa. The specimens had low chloride ion penetrability with total passed charge value was less than 1742 C. After 300 freezing-thawing cycles, the strength deduction and mass loss were less than 16% and 1.6%, respectively. The water absorption increased with the replacement level, while the autogenous shrinkage can be reduced significantly as over 10% of cement replaced by CBP. The non-evaporable water decreased but not proportionally to the substitution level. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:128 / 136
页数:9
相关论文
共 28 条
[1]  
[Anonymous], 1992, 6 RILEM
[2]  
[Anonymous], 2010, ASTM C469
[3]  
[Anonymous], 2015, Standard test method for relative density (specific gravity) and absorption of fine aggregate
[4]  
ASTM, 2010, C66697 ASTM
[5]  
ASTM, 2010, C120297 ASTM
[6]  
ASTM, 2010, C192 ASTM
[7]   Effects of crushed clay brick aggregate on mortar durability [J].
Bektas, F. ;
Wang, K. ;
Ceylan, H. .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (05) :1909-1914
[8]   Mechanical properties of brick aggregate concrete [J].
Cachim, Paulo B. .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (03) :1292-1297
[9]   Use of building rubbles as recycled aggregates [J].
Chen, HJ ;
Yen, T ;
Chen, KH .
CEMENT AND CONCRETE RESEARCH, 2003, 33 (01) :125-132
[10]   The use of coarse and fine crushed bricks as aggregate in concrete [J].
Debieb, Farid ;
Kenai, Said .
CONSTRUCTION AND BUILDING MATERIALS, 2008, 22 (05) :886-893