Direct Current Tracking Using Boundary Control With Second-Order Switching Surface for Three-Phase Three-Wire Grid-Connected Inverter

被引:23
作者
He, Yuanbin [1 ]
Chung, Henry Shu-hung [1 ]
Ho, Carl Ngai-Man [2 ]
Wu, Weimin [3 ]
机构
[1] City Univ Hong Kong, Ctr Smart Energy Convers & Utilizat Res, Kowloon Tong, Hong Kong, Peoples R China
[2] Univ Manitoba, Dept Elect & Comp Engn, Winnipeg, MB R3T 5V6, Canada
[3] Shanghai Maritime Univ, Res Inst Elect Automat, Shanghai 201306, Peoples R China
关键词
Boundary control; dc-ac power conversion; fictitious decoupled dual-buck converter; LCL filter; second-order switching surface; three-phase inverters; DIRECT POWER-CONTROL; PWM CONVERTERS; LCL; VOLTAGE; FILTER; ORDER; RESONANCE; VSI;
D O I
10.1109/TPEL.2016.2608355
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cascaded boundary-deadbeat controller can ensure system stability of single-phase grid-connected inverter operated under different grid conditions. However, it will require using numerous sensors and may experience performance degradation caused by unbalanced filter parameters in controlling a three-phase three-wire inverter. Furthermore, the system is in variable frequency operation. A boundary controller using second-order switching surface with direct current tracking capability, reduced number of current sensors, and fixed frequency operation of three-phase three-wire grid-connected inverter with inductive-capacitive-inductive (LCL) filter is presented. By applying the 60 degrees discontinuous pulsewidth modulation scheme for a fictitious decoupled dual-buck structure in each operation sector, two separate sets of switching criteria for dictating the states of the switches of two half-bridge legs are formulated. Such technique can avoid dealing with the challenges caused by the interactions among three independent current regulators. A switching table with null voltage vectors excluded is designed to dictate the switching actions. Sensitivities of the system transfer characteristics to the parametric variations are investigated. A 3 kW prototype has been built and evaluated under stiff-and weak-grid conditions. The experimental results are favorably compared with theoretical predictions.
引用
收藏
页码:5723 / 5740
页数:18
相关论文
共 45 条
[1]  
[Anonymous], P 2011 14 EUR C POW
[2]  
[Anonymous], TOK JAP MET AMCC SER
[3]   Optimal Design of High-Order Passive-Damped Filters for Grid-Connected Applications [J].
Beres, Remus Narcis ;
Wang, Xiongfei ;
Blaabjerg, Frede ;
Liserre, Marco ;
Bak, Claus Leth .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (03) :2083-2098
[4]   A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter [J].
Blasko, V ;
Kaura, V .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (02) :542-550
[5]   A Generalized Theory of Boundary Control for a Single-Phase Multilevel Inverter Using Second-Order Switching Surface [J].
Chan, Paul K. W. ;
Chung, Henry Shu-Hung ;
Hui, S. Y. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (10) :2298-2313
[6]   High-order switching surface in boundary control of inverters [J].
Chiu, Julian Yat-Chung ;
Leung, Kelvin Ka-Sing ;
Chung, Henry Shu-Hung .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (05) :1753-1765
[7]  
Cobreces S., 2007, PROC EUR C POWER ELE, P1
[8]   Digital Hysteretic Voltage-Mode Control for DC-DC Converters Based on Asynchronous Sampling [J].
Corradini, Luca ;
Orietti, Enrico ;
Mattavelli, Paolo ;
Saggini, Stefano .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (1-2) :201-211
[9]   Limitations of Voltage-Oriented PI Current Control of Grid-Connected PWM Rectifiers With LCL Filters [J].
Dannehl, Joerg ;
Wessels, Christian ;
Fuchs, Friedrich Wilhelm .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (02) :380-388
[10]  
Elsaharty M.A., 2011, IECON Proceedings (Industrial Electronics Conference), P4685, DOI [10.1109/IECON.2011.6120083, DOI 10.1109/IECON.2011.6120083]