Direct Current Tracking Using Boundary Control With Second-Order Switching Surface for Three-Phase Three-Wire Grid-Connected Inverter

被引:23
作者
He, Yuanbin [1 ]
Chung, Henry Shu-hung [1 ]
Ho, Carl Ngai-Man [2 ]
Wu, Weimin [3 ]
机构
[1] City Univ Hong Kong, Ctr Smart Energy Convers & Utilizat Res, Kowloon Tong, Hong Kong, Peoples R China
[2] Univ Manitoba, Dept Elect & Comp Engn, Winnipeg, MB R3T 5V6, Canada
[3] Shanghai Maritime Univ, Res Inst Elect Automat, Shanghai 201306, Peoples R China
关键词
Boundary control; dc-ac power conversion; fictitious decoupled dual-buck converter; LCL filter; second-order switching surface; three-phase inverters; DIRECT POWER-CONTROL; PWM CONVERTERS; LCL; VOLTAGE; FILTER; ORDER; RESONANCE; VSI;
D O I
10.1109/TPEL.2016.2608355
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cascaded boundary-deadbeat controller can ensure system stability of single-phase grid-connected inverter operated under different grid conditions. However, it will require using numerous sensors and may experience performance degradation caused by unbalanced filter parameters in controlling a three-phase three-wire inverter. Furthermore, the system is in variable frequency operation. A boundary controller using second-order switching surface with direct current tracking capability, reduced number of current sensors, and fixed frequency operation of three-phase three-wire grid-connected inverter with inductive-capacitive-inductive (LCL) filter is presented. By applying the 60 degrees discontinuous pulsewidth modulation scheme for a fictitious decoupled dual-buck structure in each operation sector, two separate sets of switching criteria for dictating the states of the switches of two half-bridge legs are formulated. Such technique can avoid dealing with the challenges caused by the interactions among three independent current regulators. A switching table with null voltage vectors excluded is designed to dictate the switching actions. Sensitivities of the system transfer characteristics to the parametric variations are investigated. A 3 kW prototype has been built and evaluated under stiff-and weak-grid conditions. The experimental results are favorably compared with theoretical predictions.
引用
收藏
页码:5723 / 5740
页数:18
相关论文
共 45 条
  • [1] [Anonymous], P 2011 14 EUR C POW
  • [2] [Anonymous], TOK JAP MET AMCC SER
  • [3] Optimal Design of High-Order Passive-Damped Filters for Grid-Connected Applications
    Beres, Remus Narcis
    Wang, Xiongfei
    Blaabjerg, Frede
    Liserre, Marco
    Bak, Claus Leth
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (03) : 2083 - 2098
  • [4] A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter
    Blasko, V
    Kaura, V
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (02) : 542 - 550
  • [5] A Generalized Theory of Boundary Control for a Single-Phase Multilevel Inverter Using Second-Order Switching Surface
    Chan, Paul K. W.
    Chung, Henry Shu-Hung
    Hui, S. Y.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (10) : 2298 - 2313
  • [6] High-order switching surface in boundary control of inverters
    Chiu, Julian Yat-Chung
    Leung, Kelvin Ka-Sing
    Chung, Henry Shu-Hung
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (05) : 1753 - 1765
  • [7] Cobreces S., 2007, PROC EUR C POWER ELE, P1
  • [8] Digital Hysteretic Voltage-Mode Control for DC-DC Converters Based on Asynchronous Sampling
    Corradini, Luca
    Orietti, Enrico
    Mattavelli, Paolo
    Saggini, Stefano
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (1-2) : 201 - 211
  • [9] Limitations of Voltage-Oriented PI Current Control of Grid-Connected PWM Rectifiers With LCL Filters
    Dannehl, Joerg
    Wessels, Christian
    Fuchs, Friedrich Wilhelm
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (02) : 380 - 388
  • [10] Elsaharty M.A., 2011, IECON Proceedings (Industrial Electronics Conference), P4685, DOI [10.1109/IECON.2011.6120083, DOI 10.1109/IECON.2011.6120083]