Bottom-Up Proteomics of Escherichia coli Using Dynamic pH Junction Preconcentration and Capillary Zone Electrophoresis-Electrospray Ionization-Tandem Mass Spectrometry

被引:61
作者
Zhu, Guijie [1 ]
Sun, Liangliang [1 ]
Yan, Xiaojing [1 ]
Dovichi, Norman J. [1 ]
机构
[1] Univ Notre Dame, Dept Chem & Biochem, Notre Dame, IN 46556 USA
基金
美国国家卫生研究院;
关键词
PEPTIDES; SENSITIVITY; INTERFACE; PROTEINS; PLATFORM; SAMPLES; SYSTEM; MS;
D O I
10.1021/ac5004486
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report the use of the dynamic pH junction based capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry (CZE-ESI-MS/MS) for bottom-up proteomics with an electrokinetically pumped sheath-flow nanospray capillary electrophoresis-mass spectrometry (CE-MS) interface and both LTQ-XL and LTQ-Orbitrap-Velos mass spectrometers. Conventional injection of 20 nL of a 1 mg/mL BSA digest identified 37 peptides and produced 66% sequence coverage. In contrast, pH junction injection of 130 nL (or larger) of a 0.05 mg/mL BSA digest identified 40 peptides and produced 70% coverage using a pH 6.5 sample buffer and the LTQ, A 20 nL conventional injection of a 1 mg/mL Escherichia coli digest identified 508 peptides and 199 proteins with the LTQ, A 400 nL pH junction injection of a 0.1 mg/mL E. coli digest identified 527 peptides and 179 proteins with the LTQ Triplicate technical replicates of a 0.01 mg/mL sample with 400-nL injection volume using a pH junction identified 288 +/- 9 peptides and 121 +/- 5 proteins with the LTQ. There was outstanding concordance in migration time between the pH junction and normal injection. The pH junction produced narrower peaks and significant concentration for all but the most acidic components in the sample. Compared with the conventional stacking method, the pH junction method can generate comparable performance for small injection volume (20 nL) and significantly better concentration performance for a large injection volume (200 nL). We also applied the pH junction to three intact standard proteins and observed a >10X increase in peak intensity compared to conventional injection.
引用
收藏
页码:6331 / 6336
页数:6
相关论文
共 22 条
  • [1] ANALYSIS OF DILUTE PEPTIDE SAMPLES BY CAPILLARY ZONE ELECTROPHORESIS
    AEBERSOLD, R
    MORRISON, HD
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01): : 79 - 88
  • [2] Selective focusing of catecholamines and weakly acidic compounds by capillary electrophoresis using a dynamic pH junction
    Britz-McKibbin, P
    Chen, DDY
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (06) : 1242 - 1252
  • [3] INTERACTION OF CAPILLARY ZONE ELECTROPHORESIS WITH A SHEATH FLOW CUVETTE DETECTOR
    CHENG, YF
    WU, SL
    CHEN, DY
    DOVICHI, NJ
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (05) : 496 - 503
  • [4] Capillary Electrophoresis
    Geiger, Matthew
    Hogerton, Amy L.
    Bowser, Michael T.
    [J]. ANALYTICAL CHEMISTRY, 2012, 84 (02) : 577 - 596
  • [5] Simple on-line sample preconcentration technique for peptides based on dynamic pH junction in capillary electrophoresis-mass spectrometry
    Imami, Koshi
    Monton, Maria Rowena N.
    Ishihama, Yasushi
    Terabe, Shigeru
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1148 (02) : 250 - 255
  • [6] CAPILLARY ZONE ELECTROPHORESIS
    JORGENSON, JW
    LUKACS, KD
    [J]. SCIENCE, 1983, 222 (4621) : 266 - 272
  • [7] Capillary electrophoresis for the analysis of biopolymers
    Krylov, SN
    Dovichi, NJ
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (12) : 111R - 128R
  • [8] Capillary Zone Electrophoresis-Electrospray Ionization-Tandem Mass Spectrometry as an Alternative Proteomics Platform to Ultraperformance Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry for Samples of Intermediate Complexity
    Li, Yihan
    Champion, Matthew M.
    Sun, Liangliang
    Champion, Patricia A. DiGiuseppe
    Wojcik, Roza
    Dovichi, Norman J.
    [J]. ANALYTICAL CHEMISTRY, 2012, 84 (03) : 1617 - 1622
  • [9] Integration of electrokinetic-based multidimensional separation/concentration platform with electrospray ionization-Fourier transform ion cyclotron resonance-mass spectrometry for proteome analysis of Shewanella oneidensis
    Mohan, D
    Pasa-Tolic, L
    Masselon, CD
    Tolic, N
    Bogdanov, B
    Hixson, KK
    Smith, RD
    Lee, CS
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (17) : 4432 - 4440
  • [10] Dynamic pH junction technique for on-line preconcentration of peptides in capillary electrophoresis
    Monton, MRN
    Imami, K
    Nakanishi, M
    Kim, JB
    Terabe, S
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1079 (1-2) : 266 - 273