Analysis of Carbon Fiber Sheet-Retrofitted RC Bridge Columns Under Lateral Cyclic Loading

被引:14
作者
Gallardo-Zafra, Richelle [1 ]
Kawashima, Kazuhiko [2 ]
机构
[1] Univ Philippines Los Banos, Dept Civil Engn, Laguna 4031, Philippines
[2] Tokyo Inst Technol, Dept Civil Engn, Tokyo 152, Japan
关键词
Bridge Columns; Reinforced Concrete; Carbon Fiber Sheet; Nonlinear Analysis; Cyclic Response; STRESS-STRAIN MODEL; REINFORCED-CONCRETE; BEHAVIOR;
D O I
10.1080/13632460802347455
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent years, the use of carbon fiber sheet (CFS) to provide lateral confinement for enhanced ductility and strength of reinforced concrete bridge columns has been increasing. While the monotonic behavior of CFS-confined concrete has been studied extensively, its cyclic response has not been fully understood. Most of the available studies are experimental investigations, hence there is a need to develop an analytical model to simulate the experimental results. Analysis of the hysteretic behavior of CFS-retrofitted circular columns is presented in this article using the fiber element that is based on cyclic constitutive models of longitudinal reinforcement and concrete confined by both CFS and tie reinforcement. The analysis was verified based on available cyclic test data and the analysis provides good agreement with the experimental results. Results show that flexural strength and ductility of columns wrapped with CFS increases as CFS ratio increases. However, as tie reinforcement ratio increases, there is no much difference on the hysteretic response for low tie reinforcement ratios. Using the fiber element analysis, the effect of CFS retrofit on the seismic response of a 7.5 m tall prototype pier built in the 1970s to 1980s is also clarified.
引用
收藏
页码:129 / 154
页数:26
相关论文
共 21 条
[1]   Experimental Study of Seismic Behaviors of As-Built and Carbon Fiber Reinforced Plastics Repaired Reinforced Concrete Bridge Columns [J].
Chang, Shuenn-Yih ;
Li, Yeou-Fong ;
Loh, Chin-Hsiung .
JOURNAL OF BRIDGE ENGINEERING, 2004, 9 (04) :391-402
[2]   Fiber-Reinforced Plastic Jackets for Ductility Enhancement of Reinforced Concrete Bridge Columns with Poor Lap-Splice Detailing [J].
Haroun, Medhat A. ;
Elsanadedy, Hussein M. .
JOURNAL OF BRIDGE ENGINEERING, 2005, 10 (06) :749-757
[3]   Stress-strain model for confined reinforced concrete in bridge piers [J].
Hoshikuma, J ;
Kawashima, K ;
Nagaya, K ;
Taylor, AW .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1997, 123 (05) :624-633
[4]  
HOSOTANI M, 1998, J MAT CONCRETE STRUC, P37
[5]  
Japan Road Association, 2002, SPEC HIGHW BRIDG 5
[6]  
KAWASHIMA K, 2000, P INT WORKSH ANN COM, V2, P124
[7]  
KAWASHIMA K, 2003, P 35 PAN WIND SEISM, P193
[8]  
KAWASHIMA K, 2006, P 4 INT WORKSH SEISM, P1
[9]  
Menegotto M., 1973, PROC IABSE S RESISTA
[10]   Behavior of concrete columns confined by fiber composites [J].
Mirmiran, A ;
Shahawy, R .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1997, 123 (05) :583-590