Accuracy of Pulmonary Nodule Volumetry Using Noise-Optimized Virtual Monoenergetic Image and Nonlinear Blending Image Algorithms in Dual-Energy Computed Tomography: A Phantom Study

被引:4
作者
He, Changjiu [1 ]
Liu, Jieke [1 ]
Hu, Shibei [1 ]
Qing, Haomiao [1 ]
Qiao, Liang [2 ]
Luo, Hongbing [1 ]
Chen, Xiaoli [1 ]
Zhou, Peng [1 ]
机构
[1] Univ Elect Sci & Technol China, Dept Radiol, Sichuan Canc Hosp & Inst, Sichuan Canc Ctr,Sch Med, Chengdu, Sichuan, Peoples R China
[2] Univ Elect Sci & Technol China, Dept Canc Prevent & Treatment, Sichuan Canc Hosp & Inst, Sichuan Canc Ctr,Sch Med, Chengdu, Sichuan, Peoples R China
关键词
pulmonary nodule volumetry; noise-optimized virtual monoenergetic image; nonlinear blending image; dual energy computed tomography; phantom;
D O I
10.1097/RCT.0000000000001102
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The aim of the study was to assess accuracy of pulmonary nodule volumetry using noise-optimized virtual monoenergetic image (VMI+) and nonlinear blending image (NBI) algorithms in dual-energy computed tomography (DECT). Methods An anthropomorphic chest phantom with 10 simulated nodules (5 solid nodules and 5 ground-glass opacities) was scanned using DECT80/Sn140kV, DECT100/Sn140kV, and single-energy CT (SECT120kV/200mAs), respectively. The dual-energy images were reconstructed using VMI+ (70 keV) and NBI algorithms. The contrast-to-noise ratio and absolute percentage error (APE) of nodule volume were measured to assess image quality and accuracy of nodule volumetry. The radiation dose was also estimated. Results The contrast-to-noise ratio of SECT120kV/200mAs was significantly higher than that of NBI80/Sn140kV and VMI+(80/Sn140kV) (both corrected P < 0.05), whereas there were no significant differences between NBI100/sn140kV and SECT120kV/200mAs and between VMI+(100/sn140kV) and SECT120kV/200mAs (both corrected P > 0.05). The APE of SECT120kV/200mAs was significantly lower than that of NBI80/Sn140kV and VMI+(80/Sn140kV) in both types of nodules (all corrected P < 0.05), whereas there were no significant differences between VMI+(100/sn140kV) and SECT120kV/200mAs in solid nodules and between NBI100/Sn140kV and SECT120kV/200mAs in ground-glass opacities (both corrected P > 0.05). The radiation dose of DECT100/Sn140kV and DECT80/Sn140kV were significantly lower than that of SECT120kV/200mAs (both corrected P < 0.05). Conclusions The DECT100/sn140kV can ensure image quality and nodule volumetry accuracy with lower radiation dose compared with SECT120kV/200mAs. Specifically, the VMI+ algorithm could be used in solid nodules and NBI algorithm in ground-glass opacities.
引用
收藏
页码:847 / 851
页数:5
相关论文
共 35 条
  • [21] Assessment of an Advanced Image-Based Technique to Calculate Virtual Monoenergetic Computed Tomographic Images From a Dual-Energy Examination to Improve Contrast-To-Noise Ratio in Examinations Using Iodinated Contrast Media
    Grant, Katharine L.
    Flohr, Thomas G.
    Krauss, Bernhard
    Sedlmair, Martin
    Thomas, Christoph
    Schmidt, Bernhard
    INVESTIGATIVE RADIOLOGY, 2014, 49 (09) : 586 - 592
  • [22] Image quality comparison of single-energy and dual-energy computed tomography for head and neck patients: a prospective randomized study
    Andreas Bedernik
    Wolfgang Wuest
    Matthias Stefan May
    Rafael Heiss
    Michael Uder
    Marco Wiesmueller
    European Radiology, 2022, 32 : 7700 - 7709
  • [23] Virtual Unenhanced Images of the Abdomen With Second-Generation Dual-Source Dual-Energy Computed Tomography Image Quality and Liver Lesion Detection
    De Cecco, Carlo Nicola
    Darnell, Anna
    Macias, Napoleon
    Ramon Ayuso, Juan
    Rodriguez, Sonia
    Rimola, Jordi
    Pages, Mario
    Garcia-Criado, Angeles
    Rengo, Marco
    Laghi, Andrea
    Ayuso, Carmen
    INVESTIGATIVE RADIOLOGY, 2013, 48 (01) : 1 - 9
  • [24] Evaluation of different keV-settings in dual-energy CT angiography of the aorta using advanced image-based virtual monoenergetic imaging
    Beeres, Martin
    Trommer, Jesko
    Frellesen, Claudia
    Nour-Eldin, Nour-Eldin A.
    Scholtz, Jan E.
    Herrmann, Eva
    Vogl, Thomas J.
    Wichmann, Julian L.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (01) : 137 - 144
  • [25] Validation of Virtual Monochromatic Images and Effect of Body Size Obtained Using a Rapid kVp-switching Dual-energy Computed Tomography System: A Phantom Study
    Wu, Tung-Hsin
    Ting, Yun-Lung
    Hwang, Yi-Shuan
    Chui, Chen-Shou
    Lin, Cristopher K. J.
    HEALTH PHYSICS, 2022, 123 (04): : 287 - 294
  • [26] Estimation of renal function using iodine maps in dual-energy spectral computed tomography urography: a feasibility and accuracy study
    Wang, Shigeng
    Tong, Xiaoyu
    Zhang, Jingyi
    Fan, Yong
    Wei, Wei
    Li, Jianying
    Liu, Yijun
    Hu, Mengting
    Chen, Qiye
    Liu, Lei
    ABDOMINAL RADIOLOGY, 2024, 49 (03) : 997 - 1005
  • [27] Estimation of renal function using iodine maps in dual-energy spectral computed tomography urography: a feasibility and accuracy study
    Shigeng Wang
    Xiaoyu Tong
    Jingyi Zhang
    Yong Fan
    Wei Wei
    Jianying Li
    Yijun Liu
    Mengting Hu
    Qiye Chen
    Lei Liu
    Abdominal Radiology, 2024, 49 : 997 - 1005
  • [28] Evaluation of femoral bone mineral density in patients with hip osteoarthritis using material density image in dual-energy computed tomography
    Takuya Tani
    Hiroki Mitsuzono
    Kazuhiro Sadasue
    Yuma Tsubaki
    Osamu Jouno
    Kojiro Nishijima
    Shohei Kudomi
    Radiological Physics and Technology, 2025, 18 (2) : 606 - 614
  • [29] Structure delineation in the presence of metal - A comparative phantom study using single and dual-energy computed tomography with and without metal artefact reduction
    Pettersson, Erik
    Back, Anna
    Bjork-Eriksson, Thomas
    Lindencrona, Ulrika
    Petruson, Karin
    Thilander-Klang, Anne
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2019, 9 : 43 - 49
  • [30] Advanced virtual monochromatic reconstruction of dual-energy unenhanced brain computed tomography in children: comparison of image quality against standard mono-energetic images and conventional polychromatic computed tomography
    Park, Juil
    Choi, Young Hun
    Cheon, Jung-Eun
    Kim, Woo Sun
    Kim, In-One
    Pak, Seong Yong
    Krauss, Bernhard
    PEDIATRIC RADIOLOGY, 2017, 47 (12) : 1648 - 1658