DSP-Based Implementation of an LQR With Integral Action for a Three-Phase Three-Wire Shunt Active Power Filter

被引:74
|
作者
Kedjar, Bachir [1 ,2 ]
Al-Haddad, Kamal [1 ,2 ]
机构
[1] Ecole Technol Super, Dept Elect Engn, Montreal, PQ H3C 1K3, Canada
[2] Ecole Technol Super, Canada Res Chair Elect Energy Convers & Power Ele, Montreal, PQ H3C 1K3, Canada
关键词
Digital signal processor (DSP); linear quadratic regulator (LQR); optimal control; shunt active power filter; CONTROLLER; SERIES; MODEL;
D O I
10.1109/TIE.2008.2006027
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents the design and implementation of a Linear Quadratic Regulator (LQR) with Integral action (LQRI) for a three-phase three-wire shunt active filter (SAF). The integral action is added so as to cancel the steady-state errors for reference tracking or disturbance rejection, knowing that the standard LQR provides only proportional gains. The controller is designed to achieve dc bus voltage regulation and harmonics and reactive power compensation. The converter model is set in the d-q rotating reference frame. The latter is augmented with the integral of the q component of the SAF currents and dc bus voltage to achieve integral action. The controller's performance depends on the weighting matrix, which is chosen to ensure satisfactory response. The converter is controlled as a whole, i.e., a multi-input-multioutput system and a fixed pulsewidth modulation at 10 kHz is used to generate the gating signals of the power devices. The system is tested for harmonics, reactive power, and load unbalance compensation for balanced/unbalanced loads. The experimental results obtained with a digital signal processor-based implementation of the controller on the DS1104 of dSPACE show good performance in terms of dc bus voltage regulation (small overshoot and very fast time response) and a low total harmonic distortion of ac line currents.
引用
收藏
页码:2821 / 2828
页数:8
相关论文
共 50 条
  • [21] Three-Level Inverter-Based Shunt Active Power Filter in Three-Phase Three-Wire and Four-Wire Systems
    Vodyakho, Oleg
    Mi, Chris C.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (5-6) : 1350 - 1363
  • [22] The Quasi-sliding Mode Control of the shunt active power filter in three-phase three-wire system
    Zhang, Xiao
    Kong, Ling-Jun
    Sun, Hua
    Zhang, Ke
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2011, 39 (21): : 40 - 44
  • [23] Research on control strategy for three-phase three-wire shunt active power filter under unbalanced loads
    Wei, Xue-liang
    Dai, Ke
    Peng, Hua-liang
    Kang, Yong
    Chen, Jian
    EUROCON 2007: THE INTERNATIONAL CONFERENCE ON COMPUTER AS A TOOL, VOLS 1-6, 2007, : 372 - 376
  • [24] Shunt Active Power Filters in Three-Phase, Three-Wire Systems: A Topical Review
    Popescu, Mihaela
    Bitoleanu, Alexandru
    Suru, Constantin Vlad
    Linca, Mihaita
    Alboteanu, Laurentiu
    ENERGIES, 2024, 17 (12)
  • [25] Globally Stable Control of Three-phase Three-wire Shunt Active Power Filters
    Hasan Kömürcügil
    Osman Kükrer
    Electrical Engineering, 2007, 89 : 411 - 418
  • [26] Parallel control strategy of three-phase three-wire shunt active power filters
    Wei, Xueliang
    Dai, Ke
    Kang, Yong
    Geng, Pan
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2007, 31 (01): : 70 - 74
  • [27] Globally stable control of three-phase three-wire shunt active power filters
    Komurcugil, Hasan
    Kukrer, Osman
    ELECTRICAL ENGINEERING, 2007, 89 (05) : 411 - 418
  • [28] OTA & CCII-Based Control System of Shunt Active Power Filter Using in Three-Phase Three-wire System
    Vanichprapa, Sombat
    Prapanavarat, Cherdchai
    Chipipop, Boonruk
    INTERNATIONAL CONFERENCE ON POWER CONTROL AND OPTIMIZATION, 2008, 1052 : 30 - +
  • [29] A three-phase four-wire power filter comprising a three-phase three-wire active power filter and a Zig-Zag transformer
    Jou, Hurng-Liahng
    Wu, Kuen-Der
    Wu, Jinn-Chang
    Chiang, Wen-Jung
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (01) : 252 - 259
  • [30] Fault tolerant control of a three-phase three-wire shunt active filter system based on reliability analysis
    Poure, P.
    Weber, P.
    Theilliol, D.
    Saadate, S.
    ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (02) : 325 - 334