MC SIMULATION FOR ESTIMATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kV X-RAY TUBE

被引:0
|
作者
Miceli, A.
Thierry, R.
Flisch, A.
Sennhauser, U.
Casali, F.
机构
关键词
Monte Carlo simulation; cone beam computed tomography; scatter;
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A Monte Carlo simulation, based on GEANT4, has been developed to compute the contribution of first order, second order, and higher order scattered radiation in a Computed Tomography (CT) system equipped with an industrial 450 kV X-ray tube and an area detector. The validation of simulation against the experimental data showed a good agreement. The amount of scattering produced by several hollow aluminum cylinders was simulated. It is shown that the scatter-to-primary ratio (SPR) is approximately 5% for the aluminum cylinder of outer diameter of 75 mm, 16% for the diameter of 100 mm, 91% for the diameter of 150 mm, and for the diameter of 200 mm it can rise to 230% in the regions corresponding to the maximum path length. Therefore, the scatter from the object significantly affects quantitative accuracy. Furthermore, the background scatter has been experimentally investigated. The results show that the background scatter plays an important rule and has to be reduced using collimators.
引用
收藏
页码:111 / 120
页数:10
相关论文
共 50 条
  • [41] Development and application of high-performance cone-beam industrial X-ray CT system
    Yang Q.
    Tan B.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2023, 31 (06): : 804 - 812
  • [42] Comparison between beam-stop and beam-hole array scatter correction techniques for industrial X-ray cone-beam CT
    Schoerner, K.
    Goldammer, M.
    Stephan, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (03): : 292 - 299
  • [43] Dual X-ray AbsorptiometryClinical Evaluation of a New Cone-Beam System
    G. M. Blake
    K. M. Knapp
    I. Fogelman
    Calcified Tissue International, 2005, 76 : 113 - 120
  • [44] Evaluation of scatter mitigation strategies for X-ray cone-beam CT: Impact of scatter subtraction and anti-scatter grids on Contrast-toNoise ratio
    Lazos, Dimitrios
    Lasio, Giovanni
    Evans, Joshua
    Williamson, Jeffrey F.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [45] Application of cone-beam X-ray CT in dento-maxillofacial region
    Maki, K
    Usui, T
    Kubota, M
    Nakano, H
    Shibasaki, Y
    Araki, K
    Okano, T
    Ueno, K
    Yamamoto, K
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 1003 - 1008
  • [46] Investigation of a Diamond X-Ray Target for Use with Megavoltage Cone-Beam CT
    Sawkey, D.
    Lu, M.
    Wu, V.
    Faddegon, B.
    Morin, O.
    Cheung, J.
    Aubin, M.
    Gangadharan, B.
    Bani-Hashemi, A.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [47] Micro cone-beam CT scanner based on X-ray polycapillary optics
    Zhou La-Zhen
    Xia Wen-Jing
    Xu Qian-Qian
    Chen Zan
    Li Fang-Zuo
    Liu Zhi-Guo
    Sun Tian-Xi
    ACTA PHYSICA SINICA, 2022, 71 (09)
  • [49] X-Ray Scatter Correction on Soft Tissue Images for Portable Cone Beam CT
    Aootaphao, Sorapong
    Thongvigitmanee, Saowapak S.
    Rajruangrabin, Jartuwat
    Thanasupsombat, Chalinee
    Srivongsa, Tanapon
    Thajchayapong, Pairash
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [50] A new X-ray scatter correction method based on BAG for cone beam CT
    Geng, Ping
    Teng, Fei
    Xiao, Dayu
    Kang, Yan
    PROCEEDING OF THE IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION, 2012, : 326 - 329