MC SIMULATION FOR ESTIMATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kV X-RAY TUBE

被引:0
|
作者
Miceli, A.
Thierry, R.
Flisch, A.
Sennhauser, U.
Casali, F.
机构
关键词
Monte Carlo simulation; cone beam computed tomography; scatter;
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A Monte Carlo simulation, based on GEANT4, has been developed to compute the contribution of first order, second order, and higher order scattered radiation in a Computed Tomography (CT) system equipped with an industrial 450 kV X-ray tube and an area detector. The validation of simulation against the experimental data showed a good agreement. The amount of scattering produced by several hollow aluminum cylinders was simulated. It is shown that the scatter-to-primary ratio (SPR) is approximately 5% for the aluminum cylinder of outer diameter of 75 mm, 16% for the diameter of 100 mm, 91% for the diameter of 150 mm, and for the diameter of 200 mm it can rise to 230% in the regions corresponding to the maximum path length. Therefore, the scatter from the object significantly affects quantitative accuracy. Furthermore, the background scatter has been experimentally investigated. The results show that the background scatter plays an important rule and has to be reduced using collimators.
引用
收藏
页码:111 / 120
页数:10
相关论文
共 50 条
  • [21] An X-Ray Fluence Modulation Apparatus for Cone-Beam CT
    Ghazi, P.
    Youssefian, S.
    Ghazi, T.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [22] X-ray scatter correction algorithm for cone beam CT imaging
    Ning, R
    Tang, XY
    Conover, D
    MEDICAL PHYSICS, 2004, 31 (05) : 1195 - 1202
  • [23] X-ray scatter suppression algorithm for cone beam volume CT
    Ning, RL
    Tang, XY
    Conover, DL
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 774 - 781
  • [24] Learning Scatter Artifact Correction in Cone-Beam X-Ray CT Using Incomplete Projections with Beam Hole Array
    Hattori, Haruki
    Yatagawa, Tatsuya
    Ohtake, Yutaka
    Suzuki, Hiromasa
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2024, 43 (03)
  • [25] Algorithm for x-ray beam hardening and scatter correction in low-dose cone-beam CT: Phantom studies
    Liu, Wenlei
    Rong, Junyan
    Gao, Peng
    Liao, Qimei
    Lu, HongBing
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [26] A beam stop based correction procedure for high spatial frequency scatter in industrial cone-beam X-ray CT
    Peterzol, A.
    Letang, J. M.
    Babot, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (18): : 4042 - 4054
  • [27] A new cone-beam X-ray CT system with a reduced size planar detector
    Li Liang
    Chen Zhi-Qiang
    Zhang Li
    Xing Yu-Xiang
    Kang Ke-Jun
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2006, 30 (08): : 812 - 817
  • [28] Library-Based X-Ray Scatter Correction for Dedicated Cone-Beam Breast CT: Clinical Validation
    Shi, L.
    Vedantham, S.
    Karellas, A.
    Zhu, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3819 - 3819
  • [29] Theoretical noise estimation in 3D X-ray cone-beam CT reconstruction
    Cai, Dongshan
    Xiao, Yongshun
    Xing, Yuxiang
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3252 - 3255
  • [30] Deep Scatter Estimation (DSE): Feasibility of Using a Deep Convolutional Neural Network for Real-Time X-Ray Scatter Prediction in Cone-Beam CT
    Maier, Joscha
    Berker, Yannick
    Sawall, Stefan
    Kachelriess, Marc
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573