Comparison of two laser Doppler systems on the measurement of blood flow of premolar teeth under different pulpal conditions

被引:8
作者
Mesaros, S [1 ]
Trope, M [1 ]
Maixner, W [1 ]
Burkes, EJ [1 ]
机构
[1] UNIV N CAROLINA, SCH DENT, DEPT ENDODONT, CHAPEL HILL, NC 27599 USA
关键词
laser Doppler flowmetry; pulpal blood flow;
D O I
10.1111/j.1365-2591.1997.tb00692.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
An in vivo investigation was conducted to assess the ability of two laser Doppler flowmeters (DRT4, Moor Instruments Ltd; Laserflo BPM2, Vasamedics) to differentiate between vital pulp, ischaemically necrosed pulp, and an empty pulp chamber in premolar teeth in children. Sixteen intact, vital teeth in need of extraction for orthodontic purposes were identified. Laser Doppler blood flow readings were taken prior to (T1) and after the administration of adrenaline-free local anaesthetic (T2), after extraction and replantation of the teeth (T3), and after broaching the pulp tissue and replanting the teeth (T4). The data collected (flux values) for both instruments were analysed using a repeated measures ANOVA. Significant differences were found for vital pulp (T1, T2) versus ischaemically necrosed pulp (T3), and for vital pulp (T1, T2) versus an empty pulp chamber (T4), with the Moor DRT4 instrument. This instrument also detected a significant difference in pulpal blood flow to the vital pulp, before and after the administration of local anaesthetic. No other significant differences were found.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
  • [21] Experiments in pigs on the sources of laser Doppler blood-flow signals recorded from teeth
    Vongsavan, N
    Matthews, B
    ARCHIVES OF ORAL BIOLOGY, 1996, 41 (01) : 97 - 103
  • [22] CALIBRATION OF LASER-DOPPLER FLOWMETRY FOR MEASUREMENT OF GINGIVAL BLOOD-FLOW
    SASANO, T
    SHOJI, N
    KURIWADA, S
    SANJO, D
    JOURNAL OF PERIODONTAL RESEARCH, 1995, 30 (04) : 298 - 301
  • [23] Analysis of changes in blood flow oscillations under different probe pressure using laser Doppler spectrum decomposition
    Kozlov, Igor O.
    Zherebtsov, Evgeny A.
    Mezentsev, Mikhail A.
    Shupletsov, Valery V.
    Potapova, Elena V.
    Zherebtsova, Angelina I.
    Dremina, Viktor V.
    Dunaev, Andrey V.
    Meglinski, Igor V.
    MEDICAL LASER APPLICATIONS AND LASER-TISSUE INTERACTIONS IX, 2019, 11079
  • [24] Blood flow measurements at different depths using photoplethysmography and laser Doppler techniques
    Bergstrand, Sara
    Lindberg, Lars Goran
    Ek, Anna-Christina
    Linden, Maria
    Lindgren, Margareta
    SKIN RESEARCH AND TECHNOLOGY, 2009, 15 (02) : 139 - 147
  • [25] The diagnostic accuracy of laser Doppler flowmetry in assessing pulp blood flow in permanent teeth: A systematic review
    Ghouth, Nahar
    Duggal, Monty S.
    BaniHani, Alaa
    Nazzal, Hani
    DENTAL TRAUMATOLOGY, 2018, 34 (05) : 311 - 319
  • [26] Laser Doppler measurement of cochlear blood flow changes during conditioning noise exposure
    Attanasio, G
    Buongiorno, G
    Piccoli, F
    Mafera, B
    Cordier, A
    Barbara, M
    Filipo, R
    ACTA OTO-LARYNGOLOGICA, 2001, 121 (04) : 465 - 469
  • [27] THE CHARACTERISTICS OF LASER-DOPPLER FLOWMETRY FOR THE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW
    FUKUDA, O
    ENDO, S
    KUWAYAMA, N
    HARADA, J
    TAKAKU, A
    NEUROSURGERY, 1995, 36 (02) : 358 - 364
  • [28] Blood flow measurement in reconstructed anterior cruciate ligaments using laser Doppler flowmetry
    Yamagishi T.
    Fujii K.
    Roppongi S.
    Hatsuumi H.
    Knee Surgery, Sports Traumatology, Arthroscopy, 1998, 6 (3) : 160 - 164
  • [29] The sources of laser Doppler blood-flow signals recorded from vital and root canal treated teeth
    Polat, S
    Er, K
    Akpinar, KE
    Polat, NT
    ARCHIVES OF ORAL BIOLOGY, 2004, 49 (01) : 53 - 57
  • [30] Comparison of temporal response to cerebral blood flow measured by laser speckle flowgraphy and laser Doppler flowmetry
    Kusano, Masashi
    Nakayama, Haruka
    Takuwa, Hiroyuki
    Masamoto, Kazuto
    Kanno, Iwao
    Okada, Eiji
    DIFFUSE OPTICAL IMAGING III, 2011, 8088