Chest electrical impedance tomography measures in neonatology and paediatrics-a survey on clinical usefulness

被引:24
作者
Frerichs, Inez [1 ]
Becher, Tobias [1 ]
机构
[1] Univ Med Ctr Schleswig Holstein, Dept Anaesthesiol & Intens Care Med, Campus Kiel, Kiel, Germany
基金
欧盟地平线“2020”;
关键词
EIT; electrical bioimpedance; respiratory system; lung; lung imaging; REGIONAL LUNG VENTILATION; VOLUME; INFANTS; CHILDREN;
D O I
10.1088/1361-6579/ab1946
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective: Chest electrical impedance tomography (EIT) is currently applied in neonatal and paediatric patients, mainly within clinical studies. The findings of these studies imply that lung monitoring using EIT provides valuable information on regional lung ventilation and aeration at the bedside that might improve the therapy and care of this fragile patient population. In view of this postulated future use of EIT in neonatology and paediatrics we have conducted an international survey to assess the perceived usefulness of several measures derived from EIT examinations. Approach: A questionnaire validating the clinical usefulness of 14 previously described EIT measures was designed and sent to 36 clinicians with previous experience with EIT in neonatal and paediatric patients. A numerical rating scale was used to assess the usefulness of each measure. Main results: Thirty-four clinicians from 12 countries responded to the invitation and 32 filled in the questionnaire. The mean clinical and EIT experience (+/- SD) of the respondents was 19.4 +/- 9.1 years and 7.7 +/- 5.8 years, respectively. The top-rated measures were the global inhomogeneity index, silent spaces, change in end-expiratory lung impedance and ventrodorsal centre of ventilation. The bottom-rated were the regional respiratory time constant, tidal volume normalised to ml, respiratory rate and heart rate on the last rank. Significance: The survey revealed that EIT measures characterising the ventilation and aeration distribution and the degree of their heterogeneity were deemed particularly useful. Respiratory rate, heart rate and overall tidal volume were considered less useful probably because these parameters are already routinely assessed by other conventional methods.
引用
收藏
页数:8
相关论文
共 36 条
  • [21] Mueller J L, 2018, PHYSIOL MEAS, V39
  • [22] Lung function tests in neonates and infants with chronic lung disease: Global and regional ventilation inhomogeneity
    Pillow, JJ
    Frerichs, I
    Stocks, J
    [J]. PEDIATRIC PULMONOLOGY, 2006, 41 (02) : 105 - 121
  • [23] Evaluation of Bedside Pulmonary Function in the Neonate: From the Past to the Future
    Reiterer, F.
    Sivieri, E.
    Abbasi, S.
    [J]. PEDIATRIC PULMONOLOGY, 2015, 50 (10) : 1039 - 1050
  • [24] Riedel T, 2010, EUR RESPIR MONOGR, P195, DOI 10.1183/1025448x.00012509
  • [25] Short-Term Effects of Elastic Chest Wall Restriction on Pulmonary Function in Children with Cystic Fibrosis
    Roethlisberger, Katrin
    Nyilas, Sylvia
    Riedel, Thomas
    Wolfensberger, Jeremy
    Singer, Florian
    Latzin, Philipp
    [J]. RESPIRATION, 2018, 96 (06) : 535 - 542
  • [26] Electrical impedance tomography to evaluate air distribution prior to extubation in very-low-birth-weight infants: a feasibility study
    Rossi, Felipe de Souza
    Zanon Yagui, Ana Cristina
    Haddad, Luciana Branco
    Deutsch, Alice D'Agostini
    Rebello, Celso Moura
    [J]. CLINICS, 2013, 68 (03) : 345 - 350
  • [27] Noninvasive Monitoring of Oxygen and Ventilation
    Smallwood, Craig D.
    Walsh, Brian K.
    [J]. RESPIRATORY CARE, 2017, 62 (06) : 751 - 764
  • [28] Clinical performance of a novel textile interface for neonatal chest electrical impedance tomography
    Sophocleous, L.
    Frerichs, I.
    Miedema, M.
    Kallio, M.
    Papadouri, T.
    Karaoli, C.
    Becher, T.
    Tingay, D. G.
    van Kaam, A. H.
    Bayford, R.
    Waldmann, A. D.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2018, 39 (04)
  • [29] Electrical impedance tomography for verification of correct endotracheal tube placement in paediatric patients: a feasibility study
    Steinmann, D.
    Engehausen, M.
    Stiller, B.
    Guttmann, J.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2013, 57 (07) : 881 - 887
  • [30] Feasibility of neonatal lung imaging using electrical impedance tomography
    Taktak, A
    Spencer, A
    Record, P
    Gadd, R
    Rolfe, P
    [J]. EARLY HUMAN DEVELOPMENT, 1996, 44 (02) : 131 - 138