Determination of 11-deoxycortisol (Reichstein's compound S) in human plasma by clinical isotope dilution mass spectrometry using benchtop gas chromatography-mass selective detection

被引:17
|
作者
Wudy, SA
Hartmann, M
Homoki, J
机构
[1] Univ Giessen, Steroid Res Unit, Childrens Hosp, Steroid Lab, D-35392 Giessen, Germany
[2] Univ Ulm, Childrens Hosp, Steroid Lab, Ulm, Germany
关键词
gas chromatography; mass spectrometry; steroid; 11-deoxycortisol; compound S; stable isotope;
D O I
10.1016/S0039-128X(02)00052-1
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A first assay based on stable isotope dilution/gas chromatography-mass spectrometry (ID/GC-MS) has been developed for plasma 11-deoxycortisol (Reichstein's compound S), the leading hormonal marker of 11beta-hydroxylase deficiency. A suitable internal standard being unavailable, we synthesized dideuterated 11-deoxycortisol according to a newly devised synthetic procedure. 17,21-Dihydroxy-pregna-1,4-diene-3,20-dione underwent selective deuteration using Wilkinson's catalyst. Our product [1alpha,2alpha-H-2(2)]11-deoxycortisol was obtained in good yield (35.6%) and high isotopic purity (0.1% H-2(0), 99.9% H-2(2)). Structural confirmation was done by MS and NMR. Our plasma work up consisted of equilibration of plasma with internal standard ([1alpha,2alpha-H-2(2)]11-deoxyconisol), solid phase extraction with Extrelut(R) NT columns, a clean up step using Sephadex LH-20 mini columns and preparation of heptafluorobutyrates as derivatives. Quantification was achieved by selected ion monitoring of m/z 465.40 (analyte) and m/z 467.40 (internal standard). One hundred twenty picograms of 11-deoxycortisol gave a signal to noise ratio of 10. Calibration plot was linear. Spiking experiments showed good accuracy with relative errors <3.0%. Intraassay precision CV was 4.78% and interassay precision CV was 4.56%. We succeeded in integrating our new analyte into our already existing multisteroid ID/GC-MS plasma assay, which now, in its expanded version, is capable of determining all major diagnostic steroids of androgen related disorders in a single profile: 11-deoxycortisol, 17alpha-hydroxyprogesterone, testosterone, 4-androstenedione, 17alpha-hydroxypregnenolone, dehydroepiandrosterone, androstanediol and 5alpha-dihydrotestosterone. The diagnostic potential of our multisteroid ID/GC-MS assay, the small amounts of plasma (0.5 ml) required, the rapid and convenient sample work up, the application of benchtop GC-MS instrumentation, and highest specificity offered by mass spectrometric detection prove our assay suitable for routine clinical use, especially in pediatric endocrinology. (C) 2002 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:851 / 857
页数:7
相关论文
共 38 条
  • [1] Determination of 17α-hydroxypregnenolone in human plasma by routine isotope dilution mass spectrometry using benchtop gas chromatography-mass selective detection
    Wudy, SA
    Hartmann, M
    Solleder, C
    Homoki, J
    STEROIDS, 2001, 66 (10) : 759 - 762
  • [2] Profiling oestrogens and testosterone in human urine by stable isotope dilution/benchtop gas chromatography-mass spectrometry
    Hoffmann, Philipp
    Hartmann, Michaela F.
    Remer, Thomas
    Zimmer, Klaus-Peter
    Wudy, Stefan A.
    STEROIDS, 2010, 75 (13-14) : 1067 - 1074
  • [3] Determination of 17-hydroxyprogesterone in plasma by stable isotope dilution/benchtop liquid chromatography-tandem mass spectrometry
    Wudy, SA
    Hartmann, M
    Svoboda, M
    HORMONE RESEARCH, 2000, 53 (02) : 68 - 71
  • [4] Determination and quantification of arbutin in plants using stable isotope dilution liquid chromatography-mass spectrometry
    Kim, Tae Jin
    Park, Young Jin
    Park, Sang Un
    Ha, Sun-Hwa
    Kim, Jae Kwang
    APPLIED BIOLOGICAL CHEMISTRY, 2018, 61 (05) : 523 - 530
  • [5] Simultaneous determination of selenomethionine enantiomers in biological fluids by stable isotope dilution gas chromatography-mass spectrometry
    Matsukawa, Takehisa
    Hasegawa, Hiroshi
    Shinohara, Yoshihiko
    Kobayashi, Jun
    Shinohara, Atsuko
    Chiba, Momoko
    Ichida, Kimiyoshi
    Yokoyama, Kazuhito
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (29): : 3253 - 3258
  • [6] Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry
    Baxter, Douglas C.
    Faarinen, Mikko
    Osterlund, Helene
    Rodushkin, Ilia
    Christensen, Morten
    ANALYTICA CHIMICA ACTA, 2011, 701 (02) : 134 - 138
  • [7] Simultaneous determination of androstenedione, 11β-hydroxyandrostenedione, and testosterone in human plasma by stable isotope dilution mass spectrometry
    Yokokawa, Akitomo
    Yamamoto, Kazuhiro
    Omori, Yuhei
    Shibasaki, Hiromi
    Shinohara, Yoshihiko
    Kasuya, Yasuji
    Furuta, Takashi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (07): : 621 - 626
  • [8] Determination of dextromethorphan in human plasma using pipette tip solid-phase extraction and gas chromatography-mass spectrometry
    Hasegawa, Chika
    Kumazawa, Takeshi
    Uchigasaki, Seisaku
    Lee, Xiao-Pen
    Sato, Keizo
    Terada, Masaru
    Kurosaki, Kunihiko
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (07) : 2215 - 2223
  • [9] Solid-phase microextraction of human plasma samples for determination of sufentanil by gas chromatography-mass spectrometry
    Paradis, C
    Dufresne, C
    Bolon, M
    Boulieu, R
    THERAPEUTIC DRUG MONITORING, 2002, 24 (06) : 768 - 774
  • [10] Determination of blood folate using acid extraction and internally standardized gas chromatography-mass spectrometry detection
    Dueker, SR
    Lin, YM
    Jones, AD
    Mercer, R
    Fabbro, E
    Miller, JW
    Green, R
    Clifford, AJ
    ANALYTICAL BIOCHEMISTRY, 2000, 283 (02) : 266 - 275