Validation of the angular measurements of a new inertial-measurement-unit based rehabilitation system: comparison with state-of-the-art gait analysis

被引:67
|
作者
Leardini, Alberto [1 ]
Lullini, Giada [1 ]
Giannini, Sandro [1 ]
Berti, Lisa [1 ]
Ortolani, Maurizio [1 ]
Caravaggi, Paolo [1 ]
机构
[1] Ist Ortoped Rizzoli, Movement Anal Lab, Bologna, Italy
来源
JOURNAL OF NEUROENGINEERING AND REHABILITATION | 2014年 / 11卷
关键词
Inertial measurement unit; Gait analysis; Rehabilitation; Knee; Hip; Thorax; Joint flexion; Audio-visual bio-feedback; Video-games; JOINT ANGLE MEASUREMENT; KINEMATICS; MOTION; SENSORS; BIOFEEDBACK; OUTCOMES; GAMES;
D O I
10.1186/1743-0003-11-136
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Several rehabilitation systems based on inertial measurement units (IMU) are entering the market for the control of exercises and to measure performance progression, particularly for recovery after lower limb orthopaedic treatments. IMU are easy to wear also by the patient alone, but the extent to which IMU's malpositioning in routine use can affect the accuracy of the measurements is not known. A new such system (Riablo (TM), CoRehab, Trento, Italy), using audio-visual biofeedback based on videogames, was assessed against state-of-the-art gait analysis as the gold standard. Methods: The sensitivity of the system to errors in the IMU's position and orientation was measured in 5 healthy subjects performing two hip joint motion exercises. Root mean square deviation was used to assess differences in the system's kinematic output between the erroneous and correct IMU position and orientation. In order to estimate the system's accuracy, thorax and knee joint motion of 17 healthy subjects were tracked during the execution of standard rehabilitation tasks and compared with the corresponding measurements obtained with an established gait protocol using stereophotogrammetry. Results: A maximum mean error of 3.1 +/- 1.8 deg and 1.9 +/- 0.8 deg from the angle trajectory with correct IMU position was recorded respectively in the medio-lateral malposition and frontal-plane misalignment tests. Across the standard rehabilitation tasks, the mean distance between the IMU and gait analysis systems was on average smaller than 5 degrees. Conclusions: These findings showed that the tested IMU based system has the necessary accuracy to be safely utilized in rehabilitation programs after orthopaedic treatments of the lower limb.
引用
收藏
页数:7
相关论文
共 28 条
  • [1] Validation of the angular measurements of a new inertial-measurement-unit based rehabilitation system: comparison with state-of-the-art gait analysis
    Alberto Leardini
    Giada Lullini
    Sandro Giannini
    Lisa Berti
    Maurizio Ortolani
    Paolo Caravaggi
    Journal of NeuroEngineering and Rehabilitation, 11
  • [2] Evaluation of Validity and Reliability of Inertial Measurement Unit-Based Gait Analysis Systems
    Cho, Young-Shin
    Jang, Seong-Ho
    Cho, Jae-Sung
    Kim, Mi-Jung
    Lee, Hyeok Dong
    Lee, Sung Young
    Moon, Sang-Bok
    ANNALS OF REHABILITATION MEDICINE-ARM, 2018, 42 (06): : 872 - 883
  • [3] Validity and repeatability of a new inertial measurement unit system for gait analysis on kinematic parameters: Comparison with an optoelectronic system
    Piche, Elodie
    Guilbot, Marine
    Chorin, Frederic
    Guerin, Olivier
    Zory, Raphael
    Gerus, Pauline
    MEASUREMENT, 2022, 198
  • [4] Determining the Most Appropriate Assistive Walking Device Using the Inertial Measurement Unit-Based Gait Analysis System in Disabled Patients
    Lee, Junhee
    Bae, Chang Hoon
    Jang, Aeri
    Yang, Seoyon
    Bae, Hasuk
    ANNALS OF REHABILITATION MEDICINE-ARM, 2020, 44 (01): : 48 - 57
  • [5] Inertial Measurement Units: A Brief State of the Art on Gait Analysis
    Ribeiro, Nuno Ferrete
    Santos, Cristina P.
    2017 IEEE 5TH PORTUGUESE MEETING ON BIOENGINEERING (ENBENG), 2017,
  • [6] Comparison of Camera based and Inertial Measurement Unit based Motion Analysis
    Jang, Seongho
    Park, Si-bog
    Moon, Sang-bog
    Kim, Jae Min
    Lee, Shi-uk
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON SENSOR NETWORKS (SENSORNETS), 2018, : 161 - 167
  • [7] Inertial Measurement Unit-Based Estimation of Foot Trajectory for Clinical Gait Analysis
    Hori, Koyu
    Mao, Yufeng
    Ono, Yumi
    Ora, Hiroki
    Hirobe, Yuki
    Sawada, Hiroyuki
    Inaba, Akira
    Orimo, Satoshi
    Miyake, Yoshihiro
    FRONTIERS IN PHYSIOLOGY, 2020, 10
  • [8] Validation of a Rowing Oar Angle Measurement System based on an Inertial Measurement Unit
    Gravenhorst, Franz
    Troester, Gerhard
    Turner, Timothy
    Smith, Richard M.
    Draper, Conny
    2013 12TH IEEE INTERNATIONAL CONFERENCE ON TRUST, SECURITY AND PRIVACY IN COMPUTING AND COMMUNICATIONS (TRUSTCOM 2013), 2013, : 1412 - 1419
  • [9] Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application
    Aqueveque, Pablo
    Gomez, Britam
    Saavedra, Francisco
    Canales, Cristian
    Contreras, Simon
    Ortega-Bastidas, Paulina
    Cano-de-la-Cuerda, Roberto
    EUROPEAN JOURNAL OF TRANSLATIONAL MYOLOGY, 2020, 30 (02) : 268 - U136
  • [10] Gait Analysis Based on an Inertial Measurement Unit Sensor: Validation of Spatiotemporal Parameters Calculation in Healthy Young and Older Adults
    Sugiarto, Tommy
    Lin, Yi-Jia
    Chang, Chao-Chin
    Hsu, Wei-Chun
    2017 IEEE/SICE INTERNATIONAL SYMPOSIUM ON SYSTEM INTEGRATION (SII), 2017, : 517 - 522