Separation and determination of seleno amino acids using gas chromatography hyphenated with inductively coupled plasma mass spectrometry after hollow fiber liquid phase microextractiion

被引:28
作者
Duan, Jiankun [1 ]
Hu, Bin [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
来源
JOURNAL OF MASS SPECTROMETRY | 2009年 / 44卷 / 05期
关键词
seleno amino acids; liquid phase microextraction; GC-ICP-MS; garlic; cabbage; mushroom; SINGLE-DROP MICROEXTRACTION; SPECIATION ANALYSIS; SAMPLE PREPARATION; ISOTOPE-DILUTION; ENRICHED YEAST; ICP-MS; SELENOMETHIONINE; DERIVATIZATION; STABILITY; EXTRACTS;
D O I
10.1002/jms.1533
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new derivatization-extraction method for preconcentration of seleno amino acids using hollow fiber liquid phase microextraction (HF-LPME) was developed for the separation and determination of seleno amino acids in biological samples by gas chromatography-inductively coupled plasma mass spectrometry (GC-ICP-MS). Derivatization was performed with ethyl chloroformate (ECF) to improve the volatility of seleno amino acids. Parameters influencing microextraction, including extraction solvent, pH of sample solution, extraction time, stirring speed, and inorganic salt concentration have been investigated. Under the optimal conditions, the limits of detection (LODs) obtained for Se-methyl-selenocysteine (SeMeCys), selenomethionine (SeMet), and selenoethionine (SeEth) were 23, 15, and 11 ng Se l(-1), respectively. The relative standard deviations (RSDs) were 14.6%, 16.4%, and 19.4% for SeMeCys, SeMet, and SeEth (c = 1.0 ng ml(-1), n = 7), respectively, and the RSDs for SeMeCys, SeMet could be improved obviously if SeEth was utilized as the internal standard. The proposed method was applied for the determination of seleno amino acids in extracts of garlic, cabbage, and mushroom samples, and the recoveries for the spiked samples were in the range of 96.8-108% and 93.4-115% with and without the use of SeEth as internal standard. The developed method was also applied to the analysis of SeMet in a certified reference material of SELM-1 yeast and the determined value is in good agreement with the certified value. Copyright (C) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:605 / 612
页数:8
相关论文
共 43 条
[1]   Speciation, quanti. cation and stability of selenomethionine, S-(methylseleno) cysteine and selenomethionine Se-oxide in yeast-based nutritional supplements [J].
Amoako, Prince O. ;
Kahakachchi, Chethaka L. ;
Dodova, Elena N. ;
Uden, Peter C. ;
Tyson, Julian F. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (08) :938-946
[2]   Seleno-compounds in garlic and onion [J].
Arnault, I ;
Auger, J .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1112 (1-2) :23-30
[3]   Selenium speciation analysis using inductively coupled plasma-mass spectrometry [J].
B'Hymer, C ;
Caruso, JA .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1114 (01) :1-20
[4]   The use of radiofrequency glow discharge-mass spectrometry (rf-GD-MS) coupled to gas chromatography for the determination of selenoaminoacids in biological samples [J].
Bayón, MM ;
B'Hymer, C ;
de León, CAP ;
Caruso, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (05) :492-497
[5]   CHEMICAL FORMS OF SELENIUM IN RAT-TISSUES AFTER ADMINISTRATION OF SELENITE OR SELENOMETHIONINE [J].
BEILSTEIN, MA ;
WHANGER, PD .
JOURNAL OF NUTRITION, 1986, 116 (09) :1711-1719
[6]   Separation of selenium compounds by CE-ICP-MS in dynamically coated capillaries applied to selenized yeast samples [J].
Bendahl, L ;
Gammelgaard, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (01) :143-148
[7]   Chromosome damage induced by selenium salts in human peripheral lymphocytes [J].
Biswas, S ;
Talukder, G ;
Sharma, A .
TOXICOLOGY IN VITRO, 2000, 14 (05) :405-408
[8]  
Calle-Guntinas M. B. de la, 1997, Journal of Analytical Atomic Spectrometry, V12, P1041, DOI 10.1039/a701695f
[9]   Chiral speciation of selenoamino acids and selenium enriched samples using HPLC coupled to ICP-MS [J].
de Leon, CAP ;
Sutton, KL ;
Caruso, JA ;
Uden, PC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (09) :1103-1107
[10]   Rapid determination of amino acids in neonatal blood samples based on derivatization with isobutyl chloroformate followed by solid-phase microextraction and gas chromatography/mass spectrometry [J].
Deng, CH ;
Li, N ;
Zhang, XM .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (21) :2558-2564