Compensation of the Effects of Muscle Fatigue on EMG-Based Control using Fuzzy Rules Based Scheme

被引:0
作者
Lalitharatne, Thilina Dulantha [1 ]
Hayashi, Yoshiaki [1 ]
Teramoto, Kenbu [1 ]
Kiguchi, Kazuo [2 ]
机构
[1] Saga Univ, Dept Adv Technol Fus, Saga 8408502, Japan
[2] Kyushu Univ, Dept Mech Engn, Fukuoka 812, Japan
来源
2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2013年
关键词
LIMB POWER-ASSIST; ROBOT; ARM;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Estimation of the correct motion intention of the user is very important for most of the Electromyography (EMG) based control applications such as prosthetics, power-assist exoskeletons, rehabilitation and teleoperation robots. On the other hand, safety and long term reliability are also vital for those applications, as they interact with human users. By considering these requirements, many EMG-based control applications have been proposed and developed. However, there are still many challenges to be addressed in the case of EMG based control systems. One of the challenges that had not been considered in such EMG-based control in common is the muscle fatigue. The muscle fatiguing effects of the user can deteriorate the effectiveness of the EMG-based control in the long run, which makes the EMG-based control to produce less accurate results. Therefore, in this study we attempted to develop a fuzzy rule based scheme to compensate the effects of muscle fatigues on EMG based control. Fuzzy rule based weights have been estimated based on time and frequency domain features of the EMG signals. Eventually, these weights have been used to modify the controller output according with the muscle fatigue condition in the muscles. The effectiveness of the proposed method has been evaluated by experiments.
引用
收藏
页码:6949 / 6952
页数:4
相关论文
共 11 条
[1]  
Andreasen DS, 2005, INT C REHAB ROBOT, P333
[2]   A Switching Regime Model for the EMG-Based Control of a Robot Arm [J].
Artemiadis, Panagiotis K. ;
Kyriakopoulos, Kostas J. .
IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS PART B-CYBERNETICS, 2011, 41 (01) :53-63
[3]   Fuzzy EMG classification for prosthesis control [J].
Chan, FHY ;
Yang, YS ;
Lam, FK ;
Zhang, YT ;
Parker, PA .
IEEE TRANSACTIONS ON REHABILITATION ENGINEERING, 2000, 8 (03) :305-311
[4]   An EMG-Based Control for an Upper-Limb Power-Assist Exoskeleton Robot [J].
Kiguchi, Kazuo ;
Hayashi, Yoshiaki .
IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS PART B-CYBERNETICS, 2012, 42 (04) :1064-1071
[5]  
Kiguchi K, 2011, IEEE ENG MED BIO, P1616, DOI 10.1109/IEMBS.2011.6090467
[6]  
Lalitharatne TD, 2012, INT CONF INF AUTOMAT, P124, DOI 10.1109/ICIAFS.2012.6419892
[7]  
Lee S, 2002, 2002 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-3, PROCEEDINGS, P1499, DOI 10.1109/IRDS.2002.1043967
[8]  
Mulas M, 2005, INT C REHAB ROBOT, P371
[9]   Static and dynamic myoelectric measures of shoulder muscle fatigue during intermittent dynamic exertions of low to moderate intensity [J].
Nussbaum, MA .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2001, 85 (3-4) :299-309
[10]   Effects of muscle kinematics on surface EMG amplitude and frequency during fatiguing dynamic contractions [J].
Potvin, JR .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 82 (01) :144-151