Validation of post-treatment PET-based dosimetry software for hepatic radioembolization of Yttrium-90 microspheres

被引:20
作者
Maughan, Nichole M. [1 ]
Garcia-Ramirez, Jose [1 ]
Arpidone, Matt [2 ]
Swallen, Amy [2 ]
Laforest, Richard [3 ]
Goddu, S. Murty [1 ]
Parikh, Parag J. [4 ]
Zoberi, Jacqueline E. [1 ]
机构
[1] Washington Univ, Dept Radiat Oncol, Sch Med, St Louis, MO 63110 USA
[2] MIM Software, Cleveland, OH 44122 USA
[3] Washington Univ, Dept Radiol, Sch Med, St Louis, MO 63110 USA
[4] Henry Ford Hosp, Dept Radiat Oncol, Detroit, MI 48202 USA
关键词
PET; MRI; post-implant dosimetry; radioembolization; Y-90; DOSE-RESPONSE; HEPATOCELLULAR-CARCINOMA; 3-DIMENSIONAL DOSIMETRY; QUANTIFICATION; LOCALIZATION; ALBUMIN;
D O I
10.1002/mp.13444
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Yttrium-90 (Y-90) microsphere radioembolization enables selective internal radiotherapy for hepatic malignancies. Currently, there is no standard postdelivery imaging and dosimetry of the microsphere distribution to verify treatment. Recent studies have reported utilizing the small positron yield of Y-90 (32 ppm) with positron emission tomography (PET) to perform treatment verification and dosimetry analysis. In this study, we validated a commercial dosimetry software, MIM SurePlan (TM) LiverY90 (MIM Software Inc., Cleveland, OH), for clinical use. Methods A MATLAB-based algorithm for Y-90 PET-based dosimetry was developed in-house and validated for the purpose of commissioning the commercial software. The algorithm is based on voxel S values and dosimetry formalism reported in MIRD Pamphlet 17. We validated the in-house algorithm to establish it as the ground truth by comparing results from a digital point phantom and a digital uniform cylinder to manual calculations. Once we validated our in-house MATLAB-based algorithm, we used it to perform acceptance testing and commissioning of the commercial dosimetry software, MIM SurePlan, which uses the same dosimetry formalism. A 0.4 cm/5% gamma test was performed on PET-derived dose maps from each algorithm of uniform digital and nonuniform physical phantoms filled with Y-90 chloride solution. Average dose (D-avg) and minimum dose to 70% (D-70) of a given volume of interest (VOI) were compared for the digital phantom, the physical phantom, and five patient cases (27 tumor VOIs), representing different clinical scenarios. Results The gamma-pass rates were 97.26% and 97.66% for the digital and physical phantoms, respectively. The differences between D-avg and D-70 were 0.076% and 0.10% for the digital phantom, respectively, and <5.2% for various VOIs in the physical phantom. In the clinical cases, 96.3% of the VOIs had a difference <5% for D-avg, and 88.9% of the VOIs had a difference Dose calculation results from MIM SurePlan were found to be in good agreement with our in-house algorithm. This indicates that MIM SurePlan performs as it should and, hence, can be deemed accepted and commissioned for clinical use for post-implant PET-based dosimetry of Y-90 radioembolization. (c) 2019 American Association of Physicists in Medicine
引用
收藏
页码:2394 / 2402
页数:9
相关论文
共 28 条
  • [21] SGOUROS G, 1993, J NUCL MED, V34, P1595
  • [22] Effects of image noise, respiratory motion, and motion compensation on 3D activity quantification in count-limited PET images
    Siman, W.
    Mawlawi, O. R.
    Mikell, J. K.
    Mourtada, F.
    Kappadath, S. C.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (02) : 448 - 464
  • [23] Srinivas SM, 2016, HDB RADIOEMBOLIZATIO, P65
  • [24] Predictive Value of Intratumoral 99mTc-Macroaggregated Albumin Uptake in Patients with Colorectal Liver Metastases Scheduled for Radioembolization with 90Y-Microspheres
    Ulrich, Gerhard
    Dudeck, Oliver
    Furth, Christian
    Ruf, Juri
    Grosser, Oliver S.
    Adolf, Daniela
    Stiebler, Marvin
    Ricke, Jens
    Amthauer, Holger
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (04) : 516 - 522
  • [25] Insights into the Dose-Response Relationship of Radioembolization with Resin 90Y-Microspheres: A Prospective Cohort Study in Patients with Colorectal Cancer Liver Metastases
    van den Hoven, Andor F.
    Rosenbaum, Charlotte E. N. M.
    Elias, Sjoerd G.
    de Jong, Hugo W. A. M.
    Koopman, Miriam
    Verkooijen, Helena M.
    Alavi, Abass
    van den Bosch, Maurice A. A. J.
    Lam, Marnix G. E. H.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (07) : 1014 - 1019
  • [26] Willowson Kathy P, 2017, Asia Ocean J Nucl Med Biol, V5, P66, DOI 10.22038/aojnmb.2016.7892
  • [27] Clinical and imaging-based prognostic factors in radioembolisation of liver metastases from colorectal cancer: a retrospective exploratory analysis
    Willowson, Kathy P.
    Hayes, Aimee R.
    Chan, David L. H.
    Tapner, Michael
    Bernard, Elizabeth J.
    Maher, Richard
    Pavlakis, Nick
    Clarke, Stephen J.
    Bailey, Dale L.
    [J]. EJNMMI RESEARCH, 2017, 7
  • [28] A multicentre comparison of quantitative 90Y PET/CT for dosimetric purposes after radioembolization with resin microspheres
    Willowson, Kathy P.
    Tapner, Michael
    Bailey, Dale L.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (08) : 1202 - 1222